Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Publication year range
2.
Zhonghua Nan Ke Xue ; 17(6): 511-5, 2011 Jun.
Article in Chinese | MEDLINE | ID: mdl-21735649

ABSTRACT

OBJECTIVE: To study the semen quality of male infertility patients in Suzhou area, China. METHODS: We detected the semen quality of 2 640 infertility patients in Suzhou area using computer-assisted semen analysis technology. RESULTS: Of the 2 640 semen samples, 27.35% were found normal in all seminal indexes, 47.35% (1 250/2 640) abnormal in the percentage of grade a + b sperm, and 42.39% (1 119/2 640) abnormal in sperm motility. The percentage of grade a + b sperm and sperm motility were decreased with the increase of age, more obviously in those over 40 years. The incidences of asthenospermia and oligospermia were 37.31% (985/2 640) and 8.94% (236/2 640), rising with the increase of age, especially in those older than 30 years. The 9 sperm motion parameters, including VSL, VCL, LIN, MAD, VAP, STR, WOB, ALH and BCF, were significantly reduced with the decrease of sperm motility and sperm concentration. CONCLUSION: The infertile men in Suzhou area are mainly characterized by a decrease in sperm motility, especially in the percentage of grade a + b sperm. The correlation of age with sperm motility and incidence of asthenospermia and oligospermia suggests that men also have an appropriate childbearing age.


Subject(s)
Infertility, Male/epidemiology , Semen Analysis , Adult , China/epidemiology , Humans , Male , Middle Aged , Sperm Count , Sperm Motility
3.
J Environ Sci (China) ; 15(4): 510-3, 2003 Jul.
Article in English | MEDLINE | ID: mdl-12974313

ABSTRACT

In order to evaluate the applicability of the organic polymeric flocculants (OPF) in the treatment of oil refinery sludge, experiments were conducted to show that OPF have better performance of flocculation than inorganic flocculants. Both the anionic and cationic OPF have satisfactory flocculation efficiency in oil sludge treatment, but the latter are more cost-efficient. Among the over 20 types of flocculants tested, 2 OPF (CPAM-2 and HPAM-2) were selected as the treatment agents, based on their good treatment performances, oil-resistance and economic feasibility. It was demonstrated in the industrial-scale centrifugal dewatering experiments that the application of either CPAM-2 or HPAM-2 could achieve high treatment efficiency of the oil sludge dewatering and reduce the COD of centrifugal liquid to less than 1000 mg/L.


Subject(s)
Petroleum , Water Pollution/prevention & control , Accidents , Emulsions , Flocculation , Microscopy, Electron, Scanning , Polymers/chemistry , Water/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...