1.
Sci Rep ; 7(1): 14441, 2017 10 31.
Article in English | MEDLINE | ID: mdl-29089581

ABSTRACT

Current oscillometric devices for monitoring central blood pressure (BP) maintain the cuff pressure at a constant level to acquire a pulse volume plethysmography (PVP) waveform and calibrate it to brachial BP levels estimated with population average methods. A physiologic method was developed to further advance central BP measurement. A patient-specific method was applied to estimate brachial BP levels from a cuff pressure waveform obtained during conventional deflation via a nonlinear arterial compliance model. A physiologically-inspired method was then employed to extract the PVP waveform from the same waveform via ensemble averaging and calibrate it to the brachial BP levels. A method based on a wave reflection model was thereafter employed to define a variable transfer function, which was applied to the calibrated waveform to derive central BP. This method was evaluated against invasive central BP measurements from patients. The method yielded central systolic, diastolic, and pulse pressure bias and precision errors of -0.6 to 2.6 and 6.8 to 9.0 mmHg. The conventional oscillometric method produced similar bias errors but precision errors of 8.2 to 12.5 mmHg (p ≤ 0.01). The new method can derive central BP more reliably than some current non-invasive devices and in the same way as traditional cuff BP.


Subject(s)
Blood Pressure Determination/methods , Blood Pressure/physiology , Aged , Arm , Arterial Pressure , Brachial Artery/physiology , Female , Humans , Male , Middle Aged , Monitoring, Physiologic/methods , Oscillometry/methods , Systole
2.
IEEE Trans Biomed Eng ; 64(7): 1524-1534, 2017 07.
Article in English | MEDLINE | ID: mdl-28113300

ABSTRACT

OBJECTIVE: pulse transit time (PTT) varies with blood pressure (BP) throughout the cardiac cycle, yet, because of wave reflection, only one PTT value at the diastolic BP level is conventionally estimated from proximal and distal BP waveforms. The objective was to establish a technique to estimate multiple PTT values at different BP levels in the cardiac cycle. METHODS: a technique was developed for estimating PTT as a function of BP (to indicate the PTT value for every BP level) from proximal and distal BP waveforms. First, a mathematical transformation from one waveform to the other is defined in terms of the parameters of a nonlinear arterial tube-load model accounting for BP-dependent arterial compliance and wave reflection. Then, the parameters are estimated by optimally fitting the waveforms to each other via the model-based transformation. Finally, PTT as a function of BP is specified by the parameters. The technique was assessed in animals and patients in several ways including the ability of its estimated PTT-BP function to serve as a subject-specific curve for calibrating PTT to BP. RESULTS: the calibration curve derived by the technique during a baseline period yielded bias and precision errors in mean BP of 5.1 ± 0.9 and 6.6 ± 1.0 mmHg, respectively, during hemodynamic interventions that varied mean BP widely. CONCLUSION: the new technique may permit, for the first time, estimation of PTT values throughout the cardiac cycle from proximal and distal waveforms. SIGNIFICANCE: the technique could potentially be applied to improve arterial stiffness monitoring and help realize cuff-less BP monitoring.


Subject(s)
Arterial Pressure/physiology , Arteries/physiology , Blood Pressure Determination/methods , Models, Cardiovascular , Pulsatile Flow/physiology , Pulse Wave Analysis/methods , Algorithms , Animals , Computer Simulation , Diagnosis, Computer-Assisted , Dogs , Humans , Nonlinear Dynamics , Reproducibility of Results , Sensitivity and Specificity , Vascular Resistance/physiology , Vascular Stiffness/physiology
3.
Sci Rep ; 6: 33230, 2016 09 14.
Article in English | MEDLINE | ID: mdl-27624389

ABSTRACT

Generalized transfer functions (GTFs) are available to compute the more relevant central blood pressure (BP) waveform from a more easily measured radial BP waveform. However, GTFs are population averages and therefore may not adapt to variations in pulse pressure (PP) amplification (ratio of radial to central PP). A simple adaptive transfer function (ATF) was developed. First, the transfer function is defined in terms of the wave travel time and reflection coefficient parameters of an arterial model. Then, the parameters are estimated from the radial BP waveform by exploiting the observation that central BP waveforms exhibit exponential diastolic decays. The ATF was assessed using the original data that helped popularize the GTF. These data included radial BP waveforms and invasive reference central BP waveforms from cardiac catheterization patients. The data were divided into low, middle, and high PP amplification groups. The ATF estimated central BP with greater accuracy than GTFs in the low PP amplification group (e.g., central systolic BP and PP root-mean-square-errors of 3.3 and 4.2 mm Hg versus 6.2 and 7.1 mm Hg; p ≤ 0.05) while showing similar accuracy in the higher PP amplification groups. The ATF may permit more accurate, non-invasive central BP monitoring in elderly and hypertensive patients.


Subject(s)
Blood Pressure , Models, Cardiovascular , Humans
4.
Physiol Rep ; 4(10)2016 May.
Article in English | MEDLINE | ID: mdl-27233300

ABSTRACT

Pulse transit time (PTT) measured as the time delay between invasive proximal and distal blood pressure (BP) or flow waveforms (invasive PTT [I-PTT]) tightly correlates with BP PTT estimated as the time delay between noninvasive proximal and distal arterial waveforms could therefore permit cuff-less BP monitoring. A popular noninvasive PTT estimate for this application is the time delay between ECG and photoplethysmography (PPG) waveforms (pulse arrival time [PAT]). Another estimate is the time delay between proximal and distal PPG waveforms (PPG-PTT). PAT and PPG-PTT were assessed as markers of BP over a wide physiologic range using I-PTT as a reference. Waveforms for determining I-PTT, PAT, and PPG-PTT through central arteries were measured from swine during baseline conditions and infusions of various hemodynamic drugs. Diastolic, mean, and systolic BP varied widely in each subject (group average (mean ± SE) standard deviation between 25 ± 2 and 36 ± 2 mmHg). I-PTT correlated well with all BP levels (group average R(2) values between 0.86 ± 0.03 and 0.91 ± 0.03). PPG-PTT also correlated well with all BP levels (group average R(2) values between 0.81 ± 0.03 and 0.85 ± 0.02), and its R(2) values were not significantly different from those of I-PTT PAT correlated best with systolic BP (group average R(2) value of 0.70 ± 0.04), but its R(2) values for all BP levels were significantly lower than those of I-PTT (P < 0.005) and PPG-PTT (P < 0.02). The pre-ejection period component of PAT was responsible for its inferior correlation with BP In sum, PPG-PTT was not different from I-PTT and superior to the popular PAT as a marker of BP.


Subject(s)
Blood Pressure/physiology , Pulse Wave Analysis/methods , Pulse Wave Analysis/standards , Animals , Blood Pressure Determination/methods , Blood Pressure Determination/standards , Swine , Time Factors
5.
Article in English | MEDLINE | ID: mdl-25571548

ABSTRACT

Emax- the maximal left ventricular elastance- is perhaps the best available scalar index of contractility. However, the conventional method for its measurement involves obtaining multiple ventricular pressure-volume loops at different loading conditions and is thus impractical. We previously proposed a more practical technique for tracking Emax from just a single beat of an aortic pressure waveform based on a lumped parameter model of the left ventricle and arteries. Here, we tested the technique against the conventional Emax measurement method in animals during inotropic interventions. Our results show that the estimated Emax changes corresponded fairly well to the reference changes, with a correlation coefficient of 0.793. With further development and testing, the technique could ultimately permit continuous and less invasive monitoring of Emax.


Subject(s)
Aorta/physiology , Adrenergic beta-1 Receptor Agonists/pharmacology , Animals , Aorta/drug effects , Arterial Pressure , Dobutamine/pharmacology , Dogs , Elasticity , Ventricular Function
6.
Article in English | MEDLINE | ID: mdl-24109665

ABSTRACT

We performed a comparative analysis of reduced arterial models. These models are characterized by a few parameters that can be uniquely estimated from the limited measurements often available in practice. Hence, they offer a means to improve hemodynamic monitoring. We specifically describe Windkessel, transmission-line, and recursive difference equation models, show how they are related, pinpoint their capabilities and limitations, and review how we have applied them for less invasive cardiac output monitoring.


Subject(s)
Arterial Pressure , Arteries/physiology , Algorithms , Blood Pressure Determination , Cardiac Output , Humans , Models, Cardiovascular
7.
Article in English | MEDLINE | ID: mdl-23365873

ABSTRACT

Pulse transit time (PTT) often shows strong correlation with blood pressure (BP) and may therefore represent a means for achieving continuous, non-invasive, and cuff-less BP monitoring. However, construction of the subject-specific curve needed to calibrate PTT to BP conventionally requires simultaneous measurements of PTT and BP during an experimental perturbation that varies BP over a significant range. We propose a technique for perturbationless calibration of PTT to BP. This technique constructs the calibration curve from central and peripheral BP waveforms by exploiting the natural pulsatile variation in the waveforms via a nonlinear tube-load model. We conducted initial testing of the technique in animals by applying it to the waveforms during a baseline period and then predicting mean BP during subsequent major hemodynamic interventions via PTT calibrated with the resulting curve. The bias in the mean BP error was 4.9 mmHg, while the precision in this error was 7.6 mmHg.


Subject(s)
Blood Pressure Monitors , Blood Pressure , Models, Cardiovascular , Nonlinear Dynamics , Pulse Wave Analysis , Blood Pressure Determination/instrumentation , Blood Pressure Determination/methods , Blood Pressure Determination/standards , Calibration/standards , Humans , Pulse Wave Analysis/instrumentation , Pulse Wave Analysis/methods
8.
J Appl Physiol (1985) ; 111(6): 1681-6, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21960657

ABSTRACT

Pulse transit time (PTT) is a proven, simple to measure, marker of blood pressure (BP) that could potentially permit continuous, noninvasive, and cuff-less BP monitoring (after an initial calibration). However, pulse arrival time (PAT), which is equal to the sum of PTT and the pre-ejection period, is gaining popularity for BP tracking, because it is even simpler to measure. The aim of this study was to evaluate the hypothesis that PAT is an adequate surrogate for PTT as a marker of BP. PAT and PTT were estimated through the aorta using high-fidelity invasive arterial waveforms obtained from six dogs during wide BP changes induced by multiple interventions. These time delays and their reciprocals were evaluated in terms of their ability to predict diastolic, mean, and systolic BP (DBP, MBP, and SBP) per animal. The root mean squared error (RMSE) between the BP parameter predicted via the time delay and the measured BP parameter was specifically used as the evaluation metric. Taking the reciprocals of the time delays tended to reduce the RMSE values. The DBP, MBP, and SBP RMSE values for 1/PAT were 9.8 ± 5.2, 10.4 ± 5.6, and 11.9 ± 6.1 mmHg, whereas the corresponding values for 1/PTT were 5.3 ± 1.2, 4.8 ± 1.0, and 7.5 ± 2.2 mmHg (P < 0.05). Thus tracking BP via PAT was not only markedly worse than via PTT but also unable to meet the FDA BP error limits. In contrast to previous studies, our results quantitatively indicate that PAT is not an adequate surrogate for PTT in terms of detecting challenging BP changes.


Subject(s)
Blood Pressure Determination/methods , Blood Pressure/physiology , Pulse , Animals , Cardiovascular Physiological Phenomena , Diastole , Dogs , Heart Rate/physiology , Monitoring, Physiologic , Systole , Time Factors
9.
Article in English | MEDLINE | ID: mdl-22255288

ABSTRACT

We proposed a technique for estimating beat-to-beat pulse transit time (PTT) from central and peripheral blood pressure or flow waveforms based on an arterial tube-load model of wave reflection. The technique effectively estimates PTT from the entire waveforms after mathematically eliminating the reflected wave. So, unlike the conventional foot-to-foot detection technique, this technique should be robust to artifact while revealing the true PTT (i.e., the PTT in absence of wave reflection). We compared the two techniques, as applied to blood pressure and flow waveforms, in terms of the ability of their PTT estimates to correlate with blood pressure (a) during baseline (for which the naturally occurring beat-to-beat changes were small), (b) during low heart rate (wherein wave reflection was profound), and (c) in the presence of actual measurement artifact. In all three cases, the PTT estimates of the arterial tube-load model technique yielded markedly superior correlation to blood pressure.


Subject(s)
Arteries/physiology , Blood Pressure , Models, Theoretical , Heart Rate , Humans