Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Zookeys ; 1048: 23-47, 2021.
Article in English | MEDLINE | ID: mdl-34295215

ABSTRACT

Based on combined morphological and osteological characters and molecular phylogenetics, we describe a new species of the genus Elaphe that was discovered from the south slope of the Qinling Mountains, Shaanxi, China, namely Elaphe xiphodonta sp. nov. It is distinguished from the other congeners by a combination of the following characters: dorsal scales in 21-21-17 rows, the medial 11 rows keeled; 202-204 ventral scales, 67-68 subcaudals; two preoculars (including one subpreocular); two postoculars; two anterior temporals, three posterior temporals; reduced numbers of maxillary teeth (9+2) and dentary teeth (12); sharp cutting edges on the posterior or posterolateral surface of the rear maxillary teeth and dentary teeth; dorsal head yellow, three distinct markings on the head and neck; a distinct black labial spot present in supralabials; dorsum yellow, 46-49 complete (or incomplete) large black-edged reddish brown blotches on the body and 12-19 on the tail, two rows of smaller blotches on each ventrolateral side; ventral scales yellow with mottled irregular black blotches, a few irregular small red spots dispersed on the middle of the ventral. Based on molecular phylogenetic analyses, the new species forms the sister taxon to E. zoigeensis. The discovery of this new species increases the number of the recognized species in the genus Elaphe to 17.

2.
Chin J Traumatol ; 9(3): 138-45, 2006 Jun.
Article in English | MEDLINE | ID: mdl-16723071

ABSTRACT

OBJECTIVE: To evaluate the clinical feasibility and effect of the computer-assisted auto-frame navigation system for distal locking of tibial intramedullary nails. METHODS: The hardware components of the system included a PC computer with a monitor, auto mechanical stereotactical localization cubic frame, foot holder and localization operative apparatus. Special navigation software can be used for registration of X-ray fluoroscopic images and real-time controlling navigation of tools. Twenty-one cases of close tibial and fibular fractures were treated with closed intramedullary nailing, 6 of which involved in middle third, 12 in middle and lower third, 3 in lower third. C-arm alignment and registration time, fluoroscopic time and drilling time involved in the locking procedure were recorded. The size of unreamed or reamed tibial nails ranged from 8/300-11/330. RESULTS: All distal holes except 1 were locked successfully. In 9 of 41 locked holes (21.95%), the drill bit touched the canal of locking hole without damage of the nail and clinical consequences. The fluoroscopy time per pair of screws was 2.23+/-0.31 s. CONCLUSIONS: The computer-assisted auto-frame navigation system for distal locking is well designed, easy to operate and do not need additional instruments during the procedure. The developed system enables the physician to precisely navigate surgical instruments throughout the anatomy using just a few computer-calibrated radiographic images. The total time of X-ray exposure per procedure can be significantly reduced.


Subject(s)
Bone Nails , Fracture Fixation, Intramedullary/instrumentation , Surgery, Computer-Assisted , Tibial Fractures/surgery , Adult , Equipment Design , Feasibility Studies , Female , Fluoroscopy , Humans , Male , Middle Aged , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...