Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Publication year range
1.
Ann Thorac Surg ; 93(4): e101-3, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22450105

ABSTRACT

A Fontan completion with a hybrid approach was performed on a 27-month-old girl with a univentricular heart. A large covered stent was placed between the inferior vena cava and the cavopulmonary anastomosis through a pericardial patch in the intracardiac fenestrated tunnel, circumventing the need for an occluder device for baffle closure. The child's progress has been good and she displays normal growth and acceptable clinical, ultrasonographic, and laboratory results.


Subject(s)
Fontan Procedure/methods , Heart Defects, Congenital/surgery , Child, Preschool , Female , Heart Bypass, Right , Humans , Stents , Vena Cava, Inferior/surgery
2.
Arch. Inst. Cardiol. Méx ; 68(5): 426-30, sept.-oct. 1998. tab, ilus
Article in Spanish | LILACS | ID: lil-227594

ABSTRACT

Hemos empleado el óxido nítrico en un paciente pediátrico con cardiopatía congénita de tipo canal atrio-ventricular completo con hipertensión arterial pulmonar severa, cianosis y desnutrición avanzada. Este ha sido llevado al laboratorio de cateterismo cardiaco para valorar el estado de los vasos pulmonares y precisar el daño vascular pulmonar, por lo cual se realizan pruebas farmacológicas con aire ambiente, oxígeno al 100 por ciento y óxido nítrico. En el estudio se demuestra el efecto vasodilatador importante del óxido nítrico: la presión de arteria pulmonar y resistencias arteriolares pulmonares descienden en forma notable de 8.75 U Wood/m² a 1.32 U Wood/m², el gasto pulmonar total aumenta, y el gradiente entre la presión en cuña y la del atrio izquierdo desparece. Por eso la hipertensión arterial pulmonar severa es reversible si el defecto congénito es corregido quirúrgicamente


Subject(s)
Humans , Male , Infant , Heart Defects, Congenital/therapy , Down Syndrome , Hemoglobins/analysis , Hypertension, Pulmonary/etiology , Nitric Oxide/administration & dosage , Nitric Oxide/pharmacokinetics , Nitric Oxide/metabolism , Nitric Oxide/therapeutic use , Pulmonary Gas Exchange/drug effects , Rheology
3.
Arch. Inst. Cardiol. Méx ; 68(2): 153-6, mar.-abr 1998. ilus
Article in Spanish | LILACS | ID: lil-227559

ABSTRACT

Se reporta un lactante de 38 días de vida, con 3.2 kg de peso y portador de síndrome de Down, soplo cardiaco y taquipnea. En el ecocardiograma Doppler color se encuentran persistencia del conducto arterioso e hipertensión arterial pulmonar. Se realizó cateterismo cardiaco que confirmó conducto arterioso permeable del tipo A-2 de 1.5 mm en su diámetro más angosto, con Qp/Qs de 1.8 e hipertensión arterial pulmonar. Se colocó espiral metálica de 5 cm de largo x 5 mm de diámetro por vía anterógrada a través de vena femoral, con oclusión completa del conducto y desaparición de hiperflujo e hipertensión arterial pulmonar. Concluimos que, en lactantes pequeños como en este caso, el uso de espiral metálica es una buena alternativa para el cierre del ducto arterioso


Subject(s)
Humans , Male , Child, Preschool , Cardiac Catheterization , Ductus Arteriosus, Patent/diagnosis , Ductus Arteriosus, Patent/therapy , Embolization, Therapeutic/instrumentation , Embolization, Therapeutic/methods , Down Syndrome/complications
SELECTION OF CITATIONS
SEARCH DETAIL
...