1.
Anal Methods ; 16(11): 1564-1569, 2024 Mar 14.
Article in English | MEDLINE | ID: mdl-38406836

ABSTRACT

In this comprehensive study, we evaluated the feasibility of using hydrogen instead of helium as a carrier gas in a GC-MS/MS system for pesticide residue analysis, spanning three matrices: pepper, tomato, and zucchini. Initial assessments focused on the ion source's chemical inertness, employing nitrobenzene as a benchmark to monitor the hydrogenation process. A method with a duration of less than 12 minutes was developed, achieving good chromatographic peak resolution attributable to the enhanced chromatographic performance of hydrogen as a carrier gas. The study emphasized the optimization of system parameters, testing various ion source temperatures, detector voltages, and injection volumes. Sensitivity assessments, based on the DG-SANTE criteria, indicated that the majority of compounds were identifiable at a concentration of 5 µg kg-1 (81% in tomato, 84% in pepper and 73% in zucchini). Detailed validation for reproducibility, matrix effects, and linearity across 150 pesticides unveiled generally favorable outcomes, with a notable majority of compounds displaying low matrix effects, satisfactory linearity ranges and good reproducibility with most compounds returning a relative standard deviation (RSD) below 10%. When applied to 15 real samples, the hydrogen-based system's performance was juxtaposed against a helium-based counterpart, revealing that results are very comparable between both systems. This comparative approach highlights hydrogen's potential as a reliable and efficient carrier gas in pesticide residue analysis for routine food control laboratories, overcoming difficulties resulting from the lack of helium supplies.


Subject(s)
Pesticide Residues , Pesticides , Tandem Mass Spectrometry/methods , Fruit/chemistry , Gas Chromatography-Mass Spectrometry/methods , Vegetables/chemistry , Pesticides/analysis , Helium/analysis , Pesticide Residues/analysis , Pesticide Residues/chemistry , Reproducibility of Results , Hydrogen/analysis
2.
Heliyon ; 10(1): e23564, 2024 Jan 15.
Article in English | MEDLINE | ID: mdl-38187233

ABSTRACT

The steady conditions of temperature, humidity and air flux within beehives make them a valuable location for conducting environmental monitoring of pollutants such as PAHs. In this context, the selection of an appropriate apicultural matrix plays a key role in these monitoring studies, as it maximizes the information that will be obtained in the analyses while minimizing the inaccurate results. In the present study, three apicultural matrices (honey bees, pollen and propolis) and two passive samplers (APIStrips and silicone wristbands) are compared in terms of the number and total load of PAHs detected in them. Samplings took place in a total of 11 apiaries scattered in Austria, Denmark, and Greece, with analyses performed by GC-MS/MS. Up to 14 different PAHs were identified in silicone wristbands and pollen, whereas the remaining matrices contained a maximum of five contaminants. Naphthalene, 1-methylnaphthalene, 2-methylnaphthalene, and pyrene were found to be the most prevalent substances in the environment. Recovery studies were also performed; these suggested that the chemical structure of APIStrips is likely to produce very strong interactions with PAHs, thus hindering the adequate desorption of these substances from their surface. Overall, silicone wristbands placed inside the beehives proved the most suitable matrix for PAH monitoring through honey bee colonies.