Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Oral Health ; 24(1): 871, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39090743

ABSTRACT

BACKGROUND: The aim of this research was to analyse the current literature on displaced dental implants in the mandibular body, including local and systemic variables related to their cause, and to identify the most frequent location. METHODS: The study conducted a search of three databases (Pubmed, Scopus, and Web of Science) using specific index terms such as 'dental implant', 'displacement', 'dislocation', 'displaced', and 'mandible'. The analysis focused on the direction of displacement and the characteristics of the bone tissue (bone quality, density, and quantity) in cases where dental implants were displaced. RESULTS: A total of 371 articles were obtained. Thirteen of these articles were selected and read in full. To define bone quality, the Lekholm and Zarb classification, modified by Rosas et al., was used. The type II-B bone, which is characterized by thick cortical bone surrounding cancellous bone with extremely wide medullary spaces, presented the largest number of complications. Twenty-two cases were found in which the displacement direction was horizontal. Of these, four were displaced vestibularly, fourteen lingually, and four remained in the center. Additionally, 24 cases presented vertical displacement, with 12 displaced towards the inferior border of the mandible, 9 towards the middle or adjacent to the inferior dental nerve canal, and 3 above the inferior dental nerve canal. CONCLUSION: The accidental displacement of implants within the mandibular body is associated with various risk factors, including the characteristics of the bony trabeculum and the size of the medullary spaces. It is reasonable to suggest that only an adequate pre-surgical diagnostic evaluation, with the help of high-resolution tomographic images that allow a previous evaluation of these structures, will help to have better control over the other factors, thus minimizing the risk of displacement.


Subject(s)
Dental Implants , Mandible , Humans , Dental Implants/adverse effects , Mandible/diagnostic imaging , Risk Factors , Foreign-Body Migration/prevention & control , Foreign-Body Migration/etiology , Bone Density , Dental Restoration Failure
2.
Sports Health ; : 19417381241236808, 2024 Mar 27.
Article in English | MEDLINE | ID: mdl-38544405

ABSTRACT

BACKGROUND: The aim of this study was to determine the influence of different percentages of blood flow restriction (BFR) and loads on mean propulsive velocity (MPV) and subjective perceived exertion during squat (SQ) and bench press (BP) exercises. HYPOTHESIS: Higher percentages of BFR will positively affect dependent variables, increasing MPV and reducing perceived exertion. STUDY DESIGN: Cross-sectional study. LEVEL OF EVIDENCE: Level 3. METHODS: Eight healthy young male athletes took part. Two sets of 6 repetitions at 70% 1-repetition maximum (1RM), 2 sets of 4 repetitions at 80% 1RM, and 2 sets of 2 repetitions at 90% 1RM were performed randomly; 5-minute recoveries were applied in all sets. The varying arterial occlusion pressure (AOP) applied randomly was 0% (Control [CON]), 80%, and 100%. RESULTS: No statistically significant differences in MPV were found during the BP exercise at any percentage of BFR at any percentage 1RM. During the SQ exercise, MPV results showed statistically significant increases of 5.46% (P = 0.04; ηp2 = 0.31) between CON and 100% AOP at 90% 1RM. The perceived exertion results for the BP exercise showed statistically significant reductions of -8.66% (P < 0.01; ηp2 = 0.06) between CON and 100% AOP at 90% 1RM. During the SQ exercise, the perceived exertion results showed significant reductions of -10.04% (P = 0.04; ηp2 = 0.40) between CON and 100% AOP at 80% 1RM; -5.47% (P = 0.02; ηp2 = 0.48) between CON and 80% AOP at 90% 1RM; and -11.83% (P < 0.01; ηp2 = 0.66) between CON and 100% AOP at 90% 1RM. CONCLUSION: BFR percentages ~100% AOP at 90% 1RM improved acutely MPV (only in SQ exercises) and reduced acutely perceived exertion (in both exercises). These findings are important to consider when prescribing resistance training for healthy male athletes.

3.
Sensors (Basel) ; 24(1)2024 Jan 04.
Article in English | MEDLINE | ID: mdl-38203160

ABSTRACT

The literature has yielded promising data over the past decade regarding the use of inertial sensors for the analysis of occupational ergonomics. However, despite their significant advantages (e.g., portability, lightness, low cost, etc.), their widespread implementation in the actual workplace has not yet been realized, possibly due to their discomfort or potential alteration of the worker's behaviour. This systematic review has two main objectives: (i) to synthesize and evaluate studies that have employed inertial sensors in ergonomic analysis based on the RULA method; and (ii) to propose an evaluation system for the transparency of this technology to the user as a potential factor that could influence the behaviour and/or movements of the worker. A search was conducted on the Web of Science and Scopus databases. The studies were summarized and categorized based on the type of industry, objective, type and number of sensors used, body parts analysed, combination (or not) with other technologies, real or controlled environment, and transparency. A total of 17 studies were included in this review. The Xsens MVN system was the most widely used in this review, and the majority of studies were classified with a moderate level of transparency. It is noteworthy, however, that there is a limited and worrisome number of studies conducted in uncontrolled real environments.


Subject(s)
Environment, Controlled , Ergonomics , Databases, Factual , Industry , Movement
4.
Bioengineering (Basel) ; 11(1)2024 Jan 20.
Article in English | MEDLINE | ID: mdl-38275578

ABSTRACT

Highlighting the crucial role of monitoring and quantifying lumbopelvic rhythm for spinal curvature, the Ergotex IMU, a portable, lightweight, cost-effective, and energy-efficient technology, has been specifically designed for the pelvic and lumbar area. This study investigates the concurrent validity of the Ergotex device in measuring sagittal pelvic tilt angle. We utilized an observational, repeated measures design with healthy adult males (mean age: 39.3 ± 7.6 y, body mass: 82.2 ± 13.0 kg, body height: 179 ± 8 cm), comparing Ergotex with a 3D optical tracking system. Participants performed pelvic tilt movements in anterior, neutral, and posterior conditions. Statistical analysis included paired samples t-tests, Bland-Altman plots, and regression analysis. The findings show minimal systematic error (0.08° overall) and high agreement between the Ergotex and optical tracking, with most data points falling within limits of agreement of Bland-Altman plots (around ±2°). Significant differences were observed only in the anterior condition (0.35°, p < 0.05), with trivial effect sizes (ES = 0.08), indicating that these differences may not be clinically meaningful. The high Pearson's correlation coefficients across conditions underscore a robust linear relationship between devices (r > 0.9 for all conditions). Regression analysis showed a standard error of estimate (SEE) of 1.1° with small effect (standardized SEE < 0.26 for all conditions), meaning that the expected average deviation from the true value is around 1°. These findings validate the Ergotex as an effective, portable, and cost-efficient tool for assessing sagittal pelvic tilt, with practical implications in clinical and sports settings where traditional methods might be impractical or costly.

5.
Article in English | MEDLINE | ID: mdl-32759692

ABSTRACT

Childhood anterior cruciate ligament (ACL) injuries-which can pose a major risk to a child's sporting career-have been on the rise in the last few decades. Dynamic knee valgus (DKV) has been linked to an increased risk of ACL injury. Therefore, the aim of this study was to analyze the acute effects of an ACL injury prevention protocol (ACL-IPP) and a soccer-specific fatigue protocol (SSFP) on DKV in youth male soccer players. The research hypothesis was that DKV would be reduced by the ACL-IPP and increased by the SSFP. Eighteen youth male soccer players were divided according to baseline DKV. Those with moderate or large DKV performed a neuromuscular training protocol based on activation of the abductor and external rotator hip muscles. Those with little or no DKV performed a soccer-specific fatigue protocol. DKV was assessed using the single-leg squat pre- and post-protocols in both legs. The ACL-IPP significantly decreased DKV during single-leg squat (p < 0.01, effect size = 1.39), while the SSFP significantly increased baseline DKV in the dominant leg during single-leg squat (p = 0.012; effect size = 1.74). In conclusion, the ACL-IPP appears to acutely reduce the DKV in youth male soccer players, and the SSFP seems to acutely increase the DKV in those players who showed a light or no DKV in a non-fatigue situation. By using the SSFP, it may be possible to determine which players would benefit from injury prevention programs due to increased DKV during game scenarios, while hip abductor and external rotator neuromuscular training may be beneficial for players who have moderate and severe DKV during single-leg squat under non-fatigued scenarios.


Subject(s)
Anterior Cruciate Ligament Injuries , Soccer , Warm-Up Exercise , Adolescent , Anterior Cruciate Ligament Injuries/prevention & control , Child , Fatigue , Humans , Knee Joint , Male , Soccer/injuries
SELECTION OF CITATIONS
SEARCH DETAIL
...