Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Antioxidants (Basel) ; 10(11)2021 Nov 22.
Article in English | MEDLINE | ID: mdl-34829722

ABSTRACT

In the late phase of Trypanosoma cruzi infection, parasite persistence and an exaggerated immune response accompanied by oxidative stress play a crucial role in the genesis of Chronic Chagasic Cardiomyopathy (CCC). Current treatments (Benznidazole (BNZ) and Nifurtimox) can effect only the elimination of the parasite, but are ineffective for late stage treatment and for preventing heart damage and disease progression. In vivo trypanocidal and cardioprotective activity has been reported for Lippia alba essential oils (EOs), ascribed to their two major terpenes, limonene and caryophyllene oxide. To investigate the role of antioxidant and immunomodulatory mechanisms behind these properties, chronic-T. cruzi-infected rats were treated with oral synergistic mixtures of the aforementioned EOs. For this purpose, the EOs were optimized through limonene-enrichment fractioning and by the addition of exogenous caryophyllene oxide (LIMOX) and used alone or in combined therapy with subtherapeutic doses of BNZ (LIMOXBNZ). Clinical, toxicity, inflammatory, oxidative, and parasitological (qPCR) parameters were assessed in cardiac tissue. These therapies demonstrated meaningful antioxidant and immunomodulatory activity on markers involved in CCC pathogenesis (IFN-γ, TNF-α, IL-4, IL-10, and iNOS), which could explain their significant trypanocidal properties and their noteworthy role in preventing, and even reversing, the progression of cardiac damage in chronic Chagas disease.

2.
Biomedica ; 41(Supl. 1): 47-59, 2021 05 31.
Article in English, Spanish | MEDLINE | ID: mdl-34111340

ABSTRACT

INTRODUCTION: Chagas' disease is the leading cause of infectious myocarditis worldwide. This infection caused by Trypanosoma cruzi is usually life-long and asymptomatic; however, the third part of infected people can develop severe or even fatal cardiomyopathy. As the parasitemia in the chronic phase is both low-grade and intermittent, T. cruzi infection is principally detected by serology, although this method has sensitivity and specificity limitations. OBJECTIVE: To determine the level of agreement between serologic and molecular tests in 658 voluntary blood donors from six provinces in the Colombian department of Santander. MATERIALS AND METHODS: We evaluated an array of diagnostic technologies by cross-section sampling performing a serological double diagnostic test for T. cruzi antibody detection (Chagas III ELISA™, BiosChile Group, and ARCHITECT Chagas CMIA™, Abbott), and DNA detection by polymerase chain reaction (PCR). We collected the demographic, clinical, and epidemiological information of participants. The sample size was calculated using Epidat™ and the statistical analysis was done with Stata 12.1™. RESULTS: PCR was six times more sensitive in detecting T. cruzi infection than ELISA/CMIA with prevalence values of 1.8% (12/658) and 0.3% (2/658), respectively, and kappa=0.28 (95%CI: -0.03 - 0.59). In contrast, serology showed a sensitivity of 16.7% (95%CI: 2.09 - 48.4) and a specificity of 100% (95%CI: 99.4 - 100). All seropositive samples were found to be positive by PCR. CONCLUSIONS: The implementation of PCR as a complementary method for screening donors could reduce the probability of false negative and the consequent risk of transfusional-transmission of Chagas' disease, especially in endemic regions.


Introducción. La enfermedad de Chagas constituye la principal causa de miocarditis infecciosa en el mundo. Causada por Trypanosoma cruzi, la infección puede persistir toda la vida de manera asintomática y silenciosa, pero un tercio de los infectados desarrolla cardiomiopatía grave. Debido a que la parasitemia en la fase crónica es baja e intermitente, el diagnóstico se hace principalmente mediante la detección de anticuerpos (serología), método que tiene limitaciones de sensibilidad y especificidad. Objetivo. Determinar la concordancia entre el diagnóstico serológico y molecular de T. cruzi en 658 donantes voluntarios de sangre del departamento de Santander, Colombia. Materiales y métodos. Se hizo un estudio de evaluación de tecnologías diagnósticas con muestreo transversal, utilizando un doble diagnóstico serológico para la detección de anticuerpos anti-T. cruzi (Chagas III ELISA™, BiosChile Group, y ARCHITECT Chagas CMIA™, Abbott) y la de ADN por PCR. Se recolectó la información demográfica, clínica y epidemiológica de los participantes. El tamaño de la muestra se estimó utilizando Epidat™ y el análisis estadístico se hizo mediante Stata 12.1™. Resultados. La sensibilidad de la PCR fue seis veces mayor que la de las pruebas de ELISA/CMIA, con prevalencias de 1,8 % (12/658) y 0,3 % (2/658), respectivamente, y kappa de 0,28 (IC95% -0,03 - 0,59). La sensibilidad serológica fue de 16,7 % (IC95% 2,09 - 48,4) y la especificidad de 100 % (IC95% 99,4 - 100). Todas las muestras seropositivas fueron positivas también en la PCR. Conclusiones. El uso de la PCR como método complementario para la tamización de donantes podría reducir el riesgo de falsos negativos y disminuir los casos de transmisión transfusional de la enfermedad de Chagas, especialmente en regiones endémicas.


Subject(s)
Blood Donors , Chagas Disease , Trypanosoma cruzi , Antibodies, Protozoan , Chagas Disease/diagnosis , Chagas Disease/epidemiology , Colombia/epidemiology , Humans , Polymerase Chain Reaction , Trypanosoma cruzi/genetics , Trypanosoma cruzi/immunology
3.
Bioresour Technol ; 320(Pt A): 124344, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33166883

ABSTRACT

In this study, showed a strategy to generate methane and remove organic matter removal from tequila vinasses through of anaerobic digestion assisted via bioelectrochemical power to-gas. Specific methanogenic activity (SMA) assays in batch mode were tested and a single-stage bioelectrochemical upflow anaerobic sludge blanket reactor (UASB) was evaluated to generate methane during tequila vinasses treatment. The results showed that the methane production in the bioelectrochemical UASB reactor applied at low voltage of 0.5 V and under HRT of 7 d was higher than the in the conventional UASB reactor. The specific methane production rate in bioelectrochemical UASB reactor was up to 2.9 NL CH4/L d, with a maximum methane yield of 0.32 NL CH4/g CODremoved. Similar COD removals were observed in the bioelectrochemical UASB reactor and conventional reactors (92-93%). High carbon dioxide reduction and hydrogen production were observed in the bioelectrochemical UASB reactor.


Subject(s)
Bioreactors , Waste Disposal, Fluid , Anaerobiosis , Methane , Sewage
4.
J Environ Manage ; 214: 232-241, 2018 May 15.
Article in English | MEDLINE | ID: mdl-29529583

ABSTRACT

In this study, a continuous flow stack consisting of 40 individual air-cathode MFC units was used to determine the performance of stacked MFC during domestic wastewater treatment operated with unconnected individual MFC and in series and parallel configuration. The voltages obtained from individual MFC units were of 0.08-1.1 V at open circuit voltage, while in series connection, the maximum power and current density were 2500 mW/m2 and 500 mA/m2 (4.9 V), respectively. In parallel connection, the maximum power and current density was 5.8 mW/m2 and 24 mA/m2, respectively. When the cells were not connected to each other MFC unit, the main bacterial species found in the anode biofilms were Bacillus and Lysinibacillus. After switching from unconnected to series and parallel connections, the most abundant species in the stacked MFC were Pseudomonas aeruginosa, followed by different Bacilli classes. This study demonstrated that when the stacked MFC was switched from unconnected to series and parallel connections, the pollutants removal, performance electricity and microbial community changed significantly. Voltages drops were observed in the stacked MFC, which was mainly limited by the cathodes. These voltages loss indicated high resistances within the stacked MFC, generating a parasitic cross current.


Subject(s)
Bacteria , Bioelectric Energy Sources , Wastewater , Electricity , Electrodes
5.
Water Sci Technol ; 76(3-4): 683-693, 2017 Jul.
Article in English | MEDLINE | ID: mdl-28759450

ABSTRACT

Two different air-cathode stacked microbial fuel cell (MFC) configurations were evaluated under continuous flow during the treatment of municipal wastewater and electricity production at a hydraulic retention time (HRT) of 3, 1, and 0.5 d. Stacked MFC 1 was formed by 20 individual air-cathode MFC units. The second stacked MFC (stacked MFC 2) consisted of 40 air-cathode MFC units placed in a shared reactor. The maximum voltages produced at closed circuit (1,000 Ω) were 170 mV for stacked MFC 1 and 94 mV for stacked MFC 2. Different power densities in each MFC unit were obtained due to a potential drop phenomenon and to a change in chemical oxygen demand (COD) concentrations inside reactors. The maximum power densities from individual MFC units were up to 1,107 mW/m2 for stacked MFC 1 and up to 472 mW/m2 for stacked MFC 2. The maximum power densities in stacked MFC 1 and MFC 2 connected in series were 79 mW/m2 and 4 mW/m2, respectively. Electricity generation and COD removal efficiencies were reduced when the HRT was decreased. High removal efficiencies of 84% of COD, 47% of total nitrogen, and 30% of total phosphorus were obtained during municipal wastewater treatment.


Subject(s)
Bioelectric Energy Sources , Bioreactors , Electricity , Waste Disposal, Fluid/methods , Wastewater/chemistry , Biological Oxygen Demand Analysis , Electrodes
6.
Gac Med Mex ; 153(2): 185-189, 2017.
Article in Spanish | MEDLINE | ID: mdl-28474705

ABSTRACT

INTRODUCTION: Psoriasis is a chronic inflammatory skin disease, in which an autoimmune mechanism participates, triggering an accelerated keratopoiesis. Its etiology is unknown; environmental factors, trauma, and infections are involved. The aim of this paper is to present the correlation between the index of severity of psoriasis and quality of life in patients with psoriasis. METHODS: This was a cross-sectional study in 72 patients with psoriasis, older than 15 years old, who agreed to participate in the study. We applied the Dermatology Life Quality Index and the Psoriasis Severity Index; descriptive statistics, measures of central tendency, dispersion, and correlation measures were used. RESULTS: Patients (n = 72), were 43% male, 57% female, with a mean age 51.22 (15-77) ± 14.05 years. Education: bachelor's degree 23.6%, housework occupation 26.4%, duration of the disease 12.25 (1-50) ± 10.58 years. Psoriasis plaques occurred in 88.9%, the Psoriasis Severity Index was mild in 70.8%. The result of the impact on quality of life was moderate in effect in 33.3%, the difference between the degree of involvement of the disease and the impact on quality of life was p = 0.104, and correlation between the quality of life and degree of psoriasis was p = 0.463. CONCLUSION: Quality of life is independent of the degree of disease in patients with psoriasis.


Subject(s)
Psoriasis , Quality of Life , Adolescent , Adult , Aged , Cross-Sectional Studies , Female , Humans , Male , Middle Aged , Psoriasis/diagnosis , Severity of Illness Index , Young Adult
7.
Sci Total Environ ; 571: 1172-82, 2016 Nov 15.
Article in English | MEDLINE | ID: mdl-27457673

ABSTRACT

Two full-scale biological nutrient removal systems upgraded with three physico-chemical processes (coagulation, chemical precipitation, and neutral Fenton) were evaluated in order to determine the removal of emerging pollutants (EPs) present in municipal wastewater from Mexico. Between 41 and 55 EPs were detected in the influents of two wastewater treatment plants (WWTPs), including personal care products (PPCPs), antibiotics, analgesics, antiepileptics, antilipidemics, antihypertensives, antiseptics, stimulants, and hormones. Emerging pollutants were detected at concentrations ranging from 0.69ng/L to 94,600ng/L. High concentrations of emerging pollutants were found during dry season. WWTP 1, integrated by oxidation ditches and UV light lamps, showed removal efficiencies of EPs between 20% and 22%. On the other hand, WWTP 2 consisted of anaerobic/anoxic/aerobic tanks coupled with two disinfection processes; chlorine dioxide and UV light lamps, for which the removal of EPs was significant (up to 80%). The concentrations of emerging pollutants in WWTP 1 effluent was found within a range

Subject(s)
Waste Disposal, Fluid/methods , Wastewater/analysis , Water Pollutants, Chemical/analysis , Chemical Precipitation , Environmental Monitoring , Flocculation , Hydrogen Peroxide/chemistry , Iron/chemistry , Mexico , Waste Disposal, Fluid/instrumentation
8.
Water Sci Technol ; 73(2): 445-52, 2016.
Article in English | MEDLINE | ID: mdl-26819401

ABSTRACT

The effect of different concentrations of tylosin on methane production was investigated: first methanogenesis in a biomass without contact with the antibiotic, and later the ability of the sludge to adapt to increasing concentrations of tylosin. Results showed that, for biomass that had no contact with the antibiotic, the presence of tylosin inhibits the generation of methane even at concentrations as small as 0.01 mg L(-1), and samples at concentrations above 0.5 mg L(-1) produced practically no methane, whereas, in the digesters acclimated in the presence of tylosin at a concentration of 0.01 to 0.065 mg L(-1), methanogenesis is not inhibited in the presence of antibiotic and the generation of methane is improved. This behaviour suggests the microorganisms have developed not only resistance to the antibiotic but also an ability to metabolize it.


Subject(s)
Anti-Bacterial Agents/toxicity , Drug Resistance, Microbial , Methane/metabolism , Tylosin/toxicity , Wastewater , Adaptation, Biological , Anaerobiosis , Animals , Biofuels , Biomass , Sewage , Swine
9.
Water Sci Technol ; 68(4): 894-900, 2013.
Article in English | MEDLINE | ID: mdl-23985521

ABSTRACT

This study determined a tylosin concentration in swine wastewater located in a Mexican pig farm, during different stages of the pigs' growth. The detection of antibiotics in swine wastewater is complex due to its high concentration of solids. Analytical method was developed for detection of tylosin in swine wastewater and swine slurry. Average recoveries of tylosin in the liquid and solid phase were greater than 51 and 44%, respectively, with a greater total recovery of 95%. The results indicated the presence of tylosin in swine wastewater and slurry at concentrations greater than the ones reported in the literature. In grab samples of swine wastewater, the tylosin detected showed concentrations of 56, 72 and 8.6 µg L(-1), in breeding-gestation, nursery pigs, and grow-finishing area, respectively. In composite samples, the concentration of tylosin was 11.8 µg L(-1) for the breeding-gestation area and 2.4 µg L(-1) for the grow-finishing area. For slurry, the concentration of tylosin was 20.6 and 17.8 µg L(-1), for the breeding-gestation and grow-finishing area, respectively. This study presents the detection of a high concentration of tylosin in breeding-gestation and nursery pigs. Traces of tylosin in wastewater from grow-finishing stage were found although the animals were not receiving antibiotics.


Subject(s)
Anti-Bacterial Agents/chemistry , Swine , Tylosin/chemistry , Water Pollutants, Chemical/chemistry , Agriculture , Animals , Mexico
10.
Water Sci Technol ; 66(12): 2754-63, 2012.
Article in English | MEDLINE | ID: mdl-23109595

ABSTRACT

An integrated fluidized bed reactor (FBR) has been employed as the treatment for petrochemical industry wastewaters with high organic matter and aromatic compounds, under anaerobic and aerobic conditions. The system was operated at hydraulic residence time (HRT) of 2.7 and 2.2 h in the anaerobic and aerobic reactor, respectively. The degree of fluidization in the beds was 30%. This system showed a high performance on the removal of organic matter and aromatic compounds. At different organic loading rates (OLR), the chemical oxygen demand (COD) removal in the anaerobic reactor was close to 85% and removals of the COD up to 94% were obtained in the aerobic reactor. High removals of benzene, toluene, ethylbenzene, xylenes, styrene, 1,2,4-trimethylbenzene, 1,3,5-trimethylbenzene and naphthalene were achieved in this study.


Subject(s)
Bioreactors/microbiology , Hydrocarbons, Aromatic/isolation & purification , Petroleum/analysis , Wastewater/chemistry , Water Purification/instrumentation , Water Purification/methods , Aerobiosis , Anaerobiosis , Bacteria/ultrastructure , Bacterial Adhesion , Biodegradation, Environmental , Biofilms/growth & development , Biological Oxygen Demand Analysis , Methane/analysis , Oxygen/analysis , Water Pollutants, Chemical/isolation & purification
SELECTION OF CITATIONS
SEARCH DETAIL
...