Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 24(9)2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38732798

ABSTRACT

Photoplethysmography (PPG) is a non-invasive method used for cardiovascular monitoring, with multi-wavelength PPG (MW-PPG) enhancing its efficacy by using multiple wavelengths for improved assessment. This study explores how contact force (CF) variations impact MW-PPG signals. Data from 11 healthy subjects are analyzed to investigate the still understudied specific effects of CF on PPG signals. The obtained dataset includes simultaneous recording of five PPG wavelengths (470, 525, 590, 631, and 940 nm), CF, skin temperature, and the tonometric measurement derived from CF. The evolution of raw signals and the PPG DC and AC components are analyzed in relation to the increasing and decreasing faces of the CF. Findings reveal individual variability in signal responses related to skin and vasculature properties and demonstrate hysteresis and wavelength-dependent responses to CF changes. Notably, all wavelengths except 631 nm showed that the DC component of PPG signals correlates with CF trends, suggesting the potential use of this component as an indirect CF indicator. However, further validation is needed for practical application. The study underscores the importance of biomechanical properties at the measurement site and inter-individual variability and proposes the arterial pressure wave as a key factor in PPG signal formation.


Subject(s)
Photoplethysmography , Humans , Photoplethysmography/methods , Male , Adult , Female , Signal Processing, Computer-Assisted , Skin Temperature/physiology , Young Adult
2.
Sensors (Basel) ; 23(15)2023 Aug 04.
Article in English | MEDLINE | ID: mdl-37571730

ABSTRACT

Over the past few years, there has been increased interest in photoplethysmography (PPG) technology, which has revealed that, in addition to heart rate and oxygen saturation, the pulse shape of the PPG signal contains much more valuable information. Lately, the wearable market has shifted towards a multi-wavelength and multichannel approach to increase signal robustness and facilitate the extraction of other intrinsic information from the signal. This transition presents several challenges related to complexity, accuracy, and reliability of algorithms. To address these challenges, anomaly detection stages can be employed to increase the accuracy and reliability of estimated parameters. Powerful algorithms, such as lightweight machine learning (ML) algorithms, can be used for anomaly detection in multi-wavelength PPG (MW-PPG). The main contributions of this paper are (a) proposing a set of features with high information gain for anomaly detection in MW-PPG signals in the classification context, (b) assessing the impact of window size and evaluating various lightweight ML models to achieve highly accurate anomaly detection, and (c) examining the effectiveness of MW-PPG signals in detecting artifacts.


Subject(s)
Algorithms , Photoplethysmography , Reproducibility of Results , Heart Rate/physiology , Machine Learning , Artifacts , Signal Processing, Computer-Assisted
3.
Sensors (Basel) ; 23(14)2023 Jul 24.
Article in English | MEDLINE | ID: mdl-37514922

ABSTRACT

Photoplethysmography (PPG) is widely used to assess cardiovascular health. However, its usage and standardization are limited by the impact of variable contact force and temperature, which influence the accuracy and reliability of the measurements. Although some studies have evaluated the impact of these phenomena on signal amplitude, there is still a lack of knowledge about how these perturbations can distort the signal morphology, especially for multi-wavelength PPG (MW-PPG) measurements. This work presents a modular multi-parametric sensor system that integrates continuous and real-time acquisition of MW-PPG, contact force, and temperature signals. The implemented design solution allows for a comprehensive characterization of the effects of the variations in these phenomena on the contour of the MW-PPG signal. Furthermore, a dynamic DC cancellation circuitry was implemented to improve measurement resolution and obtain high-quality raw multi-parametric data. The accuracy of the MW-PPG signal acquisition was assessed using a synthesized reference PPG optical signal. The performance of the contact force and temperature sensors was evaluated as well. To determine the overall quality of the multi-parametric measurement, an in vivo measurement on the index finger of a volunteer was performed. The results indicate a high precision and accuracy in the measurements, wherein the capacity of the system to obtain high-resolution and low-distortion MW-PPG signals is highlighted. These findings will contribute to developing new signal-processing approaches, advancing the accuracy and robustness of PPG-based systems, and bridging existing gaps in the literature.


Subject(s)
Photoplethysmography , Signal Processing, Computer-Assisted , Humans , Photoplethysmography/methods , Reproducibility of Results , Volunteers , Fingers , Heart Rate
4.
Sensors (Basel) ; 22(4)2022 Feb 11.
Article in English | MEDLINE | ID: mdl-35214290

ABSTRACT

The grown interest in healthcare applications has made biomedical engineering one of the fastest growing disciplines in recent years. Photoplethysmography (PPG) has gained popularity in recent years due to its versatility for noninvasive monitoring of vital signs such as heart rate, respiratory rate, blood oxygen saturation and blood pressure. In this work, an adjustable PPG-based educational device called PPG EduKit, which aims to facilitate the learning of the PPG technology for a wide range of engineering and medical disciplines is proposed. Through the use of this educational platform, the PPG signal can be understood, modified and implemented along with the extraction of its relevant physiological information from a didactic, intuitive and practical way. The PPG Edukit is evaluated for the extraction of physiological parameters such as heart rate and blood oxygen level, demonstrating how its features contribute to engineering and medical students to assimilate technical concepts in electrical circuits, biomedical instrumentation, and human physiology.


Subject(s)
Oximetry , Photoplethysmography , Heart Rate/physiology , Humans , Oxygen Saturation , Respiratory Rate , Signal Processing, Computer-Assisted
5.
Sensors (Basel) ; 14(4): 6797-805, 2014 Apr 14.
Article in English | MEDLINE | ID: mdl-24736132

ABSTRACT

A three-magnet array unilateral NMR sensor with a homogeneous sensitive spot was employed for assessing aging of the turbine oils used in two different power stations. The Carr-Purcell-Meiboom-Gill (CPMG) sequence and Inversion Recovery-prepared CPMG were employed for measuring the ¹H-NMR transverse and longitudinal relaxation times of turbine oils with different service status. Two signal components with different lifetimes were obtained by processing the transverse relaxation curves with a numeric program based on the Inverse Laplace Transformation. The long lifetime components of the transverse relaxation time T2eff and longitudinal relaxation time T1 were chosen to monitor the hydraulic fluid aging. The results demonstrate that an increase of the service time of the turbine oils clearly results in a decrease of T2eff,long and T1,long. This indicates that the T2eff,long and T1,long relaxation times, obtained from the unilateral magnetic resonance measurements, can be applied as indices for degradation of the hydraulic fluid in power station turbines.

6.
J Magn Reson ; 207(2): 337-44, 2010 Dec.
Article in English | MEDLINE | ID: mdl-21030276

ABSTRACT

Unilateral magnetic resonance (UMR) has become, in different research areas, a powerful tool to interrogate samples of arbitrary size. Numerous designs have been suggested in the literature to produce the desired magnetic field distributions, including designs which feature constant magnetic field gradients suitable for diffusion and profiling experiments. This work presents a new approach which features extended constant magnetic field gradients with a three magnet array. Constant gradients of more than 3cm extent can be achieved in a very simple, compact and safe design. Diffusion measurements from different positions over the magnet are presented in addition to practical applications for reservoir core plug characterization. The idea of a solenoid as a probe for specific measurements in UMR is introduced. Simple profiling experiments are also presented.


Subject(s)
Electromagnetic Fields , Magnetic Resonance Spectroscopy/instrumentation , Algorithms , Data Interpretation, Statistical , Diffusion , Time Factors
7.
J Magn Reson ; 202(2): 234-8, 2010 Feb.
Article in English | MEDLINE | ID: mdl-19969493

ABSTRACT

Magnetic resonance imaging with pure phase encoding (sometimes known as single point or constant time imaging) has many desirable advantages, but is usually time consuming in comparison to frequency encoding methods. In single point imaging the maximum signal bandwidth is proportional to both the phase-encoding gradient amplitude and the object size. It is usual practice to set the acquisition filter bandwidth to the maximum value expected during a measurement. Hence the filtering employed in this kind of measurement is not optimal for the low frequency k-space points. An optimal way to set the filter bandwidth is presented in this study. By reducing the filter bandwidth to match the point sampled in k-space, the inherent SNR is improved and this, in turn, may be used to reduce the number of signal averages required for acceptable SNR. The variable bandwidth filter offers a theoretical SNR increase of 41%. This paper shows the results of its application and comparison with fixed low-pass filtering. Practical measurements show a gain of 20% in SNR, which would translate into a 31% reduction in averaging time required for a single image without any detrimental effects on the image quality.


Subject(s)
Magnetic Resonance Imaging/statistics & numerical data , Algorithms , Electromagnetic Fields , Image Interpretation, Computer-Assisted , Magnetic Resonance Imaging/methods , Models, Statistical
SELECTION OF CITATIONS
SEARCH DETAIL
...