Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
Int J Mol Sci ; 23(17)2022 Aug 31.
Article in English | MEDLINE | ID: mdl-36077292

ABSTRACT

Multiple myeloma (MM) is the second most common haematological malignancy and remains incurable despite therapeutic advances. 18F-FDG (FDG) PET/CT is a relevant tool MM for staging and it is the reference imaging technique for treatment evaluation. However, it has limitations, and investigation of other PET tracers is required. Preliminary results with L-methyl-[11C]- methionine (MET), suggest higher sensitivity than 18F-FDG. This study aimed to compare the diagnostic accuracy and prognostic value of 1FDG and MET in MM patients. We prospectively compared FDG and MET PET/CT for assessment of bone disease and extramedullary disease (EMD) in a series of 52 consecutive patients (8 smoldering MM, 18 newly diagnosed MM and 26 relapsed MM patients). Bone marrow (BM) uptake patterns and the detection of focal lesions (FLs) and EMD were compared. Furthermore, FDG PET parameters with known MM prognostic value were explored for both tracers, as well as total lesion MET uptake (TLMU). Median patient age was 61 years (range, 37-83 years), 54% were male, 13% of them were in stage ISS (International Staging System) III, and 31% had high-risk cytogenetics. FDG PET/CT did not detect active disease in 6 patients, while they were shown to be positive by MET PET/CT. Additionally, MET PET/CT identified a higher number of FLs than FDG in more than half of the patients (63%). For prognostication we focussed on the relapsed cohort, due to the low number of progressions in the two other cohorts. Upon using FDG PET/CT in relapsed patients, the presence of more than 3 FLs (HR 4.61, p = 0.056), more than 10 FLs (HR 5.65, p = 0.013), total metabolic tumor volume (TMTV) p50 (HR 4.91, p = 0.049) or TMTV p75 (HR 5.32, p = 0.016) were associated with adverse prognosis. In MET PET/CT analysis, TMTV p50 (HR 4.71, p = 0.056), TMTV p75 (HR 6.27, p = 0.007), TLMU p50 (HR 8.8, p = 0.04) and TLMU p75 (HR 6.3, p = 0.007) adversely affected PFS. This study confirmed the diagnostic and prognostic value of FDG in MM. In addition, it highlights that MET has higher sensitivity than FDG PET/CT for detection of myeloma lesions, including FLs. Moreover, we show, for the first time, the prognostic value of TMTV and TLMU MET PET/CT in the imaging evaluation of MM patients.


Subject(s)
Multiple Myeloma , Positron Emission Tomography Computed Tomography , Adult , Aged , Aged, 80 and over , Female , Fluorodeoxyglucose F18 , Humans , Male , Methionine , Middle Aged , Multiple Myeloma/diagnostic imaging , Positron Emission Tomography Computed Tomography/methods , Prognosis , Radiopharmaceuticals , Retrospective Studies
2.
Cancers (Basel) ; 12(4)2020 Apr 23.
Article in English | MEDLINE | ID: mdl-32340251

ABSTRACT

11C-methionine (11C-MET) is a new positron emission tomography (PET) tracer for the assessment of disease activity in multiple myeloma (MM) patients, with preliminary data suggesting higher sensitivity and specificity than 18F-fluorodeoxyglucose (18F-FDG). However, the value of tumor burden biomarkers has yet to be investigated. Our goals were to corroborate the superiority of 11C-MET for MM staging and to compare its suitability for the assessment of metabolic tumor burden biomarkers in comparison to 18F-FDG. Twenty-two patients with newly diagnosed, treatment-naïve symptomatic MM who had undergone 11C-MET and 18F-FDG PET/CT were evaluated. Standardized uptake values (SUV) were determined and compared with total metabolic tumor volume (TMTV) for both tracers: total lesion glycolysis (TLG) and total lesion 11C-MET uptake (TLMU). PET-derived values were compared to Revised International Staging System (R-ISS), cytogenetic, and serologic MM markers such as M component, beta 2 microglobulin (B2M), serum free light chains (FLC), albumin, and lactate dehydrogenase (LDH). In 11 patients (50%), 11C-MET detected more focal lesions (FL) than FDG (p < 0.01). SUVmax, SUVmean, SUVpeak, TMTV, and TLMU were also significantly higher in 11C-MET than in 18F-FDG (p < 0.05, respectively). 11C-MET PET biomarkers had a better correlation with tumor burden (bone marrow plasma cell infiltration, M component; p < 0.05 versus p = n.s. respectively). This pilot study suggests that 11C-MET PET/CT is a more sensitive marker for the assessment of myeloma tumor burden than 18F-FDG. Its implications for prognosis evaluation need further investigation.

3.
Theranostics ; 7(11): 2956-2964, 2017.
Article in English | MEDLINE | ID: mdl-28824728

ABSTRACT

11C-methionine (MET) has recently emerged as an accurate marker of tumor burden and disease activity in patients with multiple myeloma (MM). This dual-center study aimed at further corroboration of the superiority of MET as positron emission tomography (PET) tracer for staging and re-staging MM, as compared to 18F-2`-deoxy-2`-fluoro-D-glucose (FDG). 78 patients with a history of solitary plasmacytoma (n=4), smoldering MM (SMM, n=5), and symptomatic MM (n=69) underwent both MET- and FDG-PET/computed tomography (CT) at the University Centers of Würzburg, Germany and Navarra, Spain. Scans were compared on a patient and on a lesion basis. Inter-reader agreement was also evaluated. In 2 patients, tumor biopsies for verification of discordant imaging results were available. MET-PET detected focal lesions (FL) in 59/78 subjects (75.6%), whereas FDG-PET/CT showed lesions in only 47 patients (60.3%; p<0.01), accordingly disease activity would have been missed in 12 patients. Directed biopsies of discordant results confirmed MET-PET/CT results in both cases. MET depicted more FL in 44 patients (56.4%; p<0.01), whereas in two patients (2/78), FDG proved superior. In the remainder (41.0%, 32/78), both tracers yielded comparable results. Inter-reader agreement for MET was higher than for FDG (κ = 0.82 vs κ = 0.72). This study demonstrates higher sensitivity of MET in comparison to standard FDG to detect intra- and extramedullary MM including histologic evidence of FDG-negative, viable disease exclusively detectable by MET-PET/CT. MET holds the potential to replace FDG as functional imaging standard for staging and re-staging of MM.


Subject(s)
Carbon Radioisotopes/administration & dosage , Isotope Labeling/methods , Methionine/administration & dosage , Multiple Myeloma/diagnostic imaging , Neoplasm Staging/methods , Positron-Emission Tomography/methods , Biological Factors/metabolism , Chelating Agents/metabolism , Germany , Glucose-6-Phosphate/administration & dosage , Glucose-6-Phosphate/analogs & derivatives , Humans , Sensitivity and Specificity , Spain
4.
EJNMMI Res ; 7(1): 37, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28439843

ABSTRACT

BACKGROUND: The aim of this study was to retrospectively evaluate the patient effective dose (ED) for different PET/CT procedures performed with a variety of PET radiopharmaceutical compounds. PET/CT studies of 210 patients were reviewed including Torso (n = 123), Whole body (WB) (n = 36), Head and Neck Tumor (HNT) (n = 10), and Brain (n = 41) protocols with 18FDG (n = 170), 11C-CHOL (n = 10), 18FDOPA (n = 10), 11C-MET (n = 10), and 18F-florbetapir (n = 10). ED was calculated using conversion factors applied to the radiotracer activity and to the CT dose-length product. RESULTS: Total ED (mean ± SD) for Torso-11C-CHOL, Torso-18FDG, WB-18FDG, and HNT-18FDG protocols were 13.5 ± 2.2, 16.5 ± 4.5, 20.0 ± 5.6, and 15.4 ± 2.8 mSv, respectively, where CT represented 77, 62, 69, and 63% of the protocol ED, respectively. For 18FDG, 18FDOPA, 11C-MET, and 18F-florbetapir brain PET/CT studies, ED values (mean ± SD) were 6.4 ± 0.6, 4.6 ± 0.4, 5.2 ± 0.5, and 9.1 ± 0.4 mSv, respectively, and the corresponding CT contributions were 11, 14, 23, and 26%, respectively. In 18FDG PET/CT, variations in scan length and arm position produced significant differences in CT ED (p < 0.01). For dual-time-point imaging, the CT ED (mean ± SD) for the delayed scan was 3.8 ± 1.5 mSv. CONCLUSIONS: The mean ED for body and brain PET/CT protocols with different radiopharmaceuticals ranged between 4.6 and 20.0 mSv. The major contributor to total ED for body protocols is CT, whereas for brain studies, it is the PET radiopharmaceutical.

5.
Eur Radiol ; 27(8): 3190-3198, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28004161

ABSTRACT

OBJECTIVE: Our aim was to evaluate the diagnostic accuracy of magnetic resonance imaging (MRI) fused with prone 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) in primary tumour staging of patients with breast cancer. METHODS: This retrospective study evaluated 45 women with 49 pathologically proven breast carcinomas. MRI and prone PET-CT scans with time-of-flight and point-spread-function reconstruction were performed with the same dedicated breast coil. The studies were assessed by a radiologist and a nuclear medicine physician, and evaluation of fused images was made by consensus. The final diagnosis was based on pathology (90 lesions) or follow-up ≥ 24 months (17 lesions). RESULTS: The study assessed 72 malignant and 35 benign lesions with a median size of 1.8 cm (range 0.3-8.4 cm): 31 focal, nine multifocal and nine multicentric cases. In lesion-by-lesion analysis, sensitivity, specificity, positive and negative predictive values were 97%, 80%, 91% and 93% for MRI, 96%, 71%, 87%, and 89% for prone PET, and 97%. 94%, 97% and 94% for MRI fused with PET. Areas under the curve (AUC) were 0.953, 0.850, and 0.983, respectively (p < 0.01). CONCLUSIONS: MRI fused with FDG-PET is more accurate than FDG-PET in primary tumour staging of breast cancer patients and increases the specificity of MRI. KEY POINTS: • FDG PET-CT may improve the specificity of MRI in breast cancer staging. • MRI fused with prone 2-[fluorine-18]-fluoro-2-deoxy-D-glucose PET-CT has better overall diagnostic performance than MRI. • The clinical role of fused PET-MRI has not yet been established.


Subject(s)
Breast Neoplasms/diagnostic imaging , Magnetic Resonance Imaging/methods , Positron Emission Tomography Computed Tomography/methods , Adult , Aged , Aged, 80 and over , Female , Fluorodeoxyglucose F18/administration & dosage , Humans , Middle Aged , Neoplasm Staging/methods , Positron-Emission Tomography/methods , Predictive Value of Tests , Prone Position , Retrospective Studies , Sensitivity and Specificity , Tomography, X-Ray Computed/methods , Young Adult
6.
Lung Cancer ; 97: 81-6, 2016 07.
Article in English | MEDLINE | ID: mdl-27237032

ABSTRACT

BACKGROUND: A major drawback of lung cancer screening programs is the high frequency of false-positive findings on computed tomography (CT). We investigated the accuracy of selective 2-[fluorine-18]-fluoro-2-deoxy-d-glucose (FDG) Positron Emission Tomography/Computed Tomography (PET/CT) scan in assessing radiologically indeterminate lung nodules detected in lung cancer screening. METHODS: FDG PET/CT was performed to characterize 64 baseline lung nodules >10mm and 36 incidence nodules detected on low-dose CT screening in asymptomatic current or former smokers (83 men, age range 40-83 years) at high risk for lung cancer. CT images were acquired without intravenous contrast. Nodules were analyzed by size, density, and metabolic activity and visual scored on a 5-point scale for FDG uptake. Nodules were classified as negative for malignancy when no FDG uptake was observed, or positive when focal uptake was observed in the visual analysis, and the maximum standardized uptake value (SUVmax) was measured. Final diagnosis was based on histopathological evaluation or at least 24 months of follow-up. RESULTS: A total of 100 nodules were included. The prevalence of lung cancer was 1%. The sensitivity, specificity, NPV and PPV of visual analysis to detect malignancy were 84%, 95%, 91%, and 91%, respectively, with an accuracy of 91% (AUC 0.893). FDG PET/CT accurately detected 31 malignant tumors (diameters 9-42mm, SUVmax range 0.6-14.2) and was falsely negative in 6 patients. With SUVmax thresholds for malignancy of 1.5, 2, and 2.5, specificity was 97% but sensitivity decreased to 65%, 49%, and 46% respectively, and accuracy decreased to 85%, 79%, and 78% respectively (AUC 0.872). CONCLUSIONS: The visual analysis of FDG PET/CT scan is highly accurate in characterizing indeterminate pulmonary nodules detected in lung cancer screening with low-dose CT. Semi-quantitative analysis does not improve the accuracy of FDG PET/CT over that obtained with a qualitative method for lung nodule characterization.


Subject(s)
Early Detection of Cancer/methods , Fluorodeoxyglucose F18/metabolism , Lung Neoplasms/diagnostic imaging , Multiple Pulmonary Nodules/diagnostic imaging , Positron Emission Tomography Computed Tomography/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Lung Neoplasms/pathology , Male , Middle Aged , Multimodal Imaging/methods , Multiple Pulmonary Nodules/pathology , Observer Variation , Retrospective Studies , Spain/epidemiology
7.
Arch. bronconeumol. (Ed. impr.) ; 51(4): 169-176, abr. 2015. tab, graf
Article in Spanish | IBECS | ID: ibc-135399

ABSTRACT

Introducción y objetivos: La experiencia europea en relación con el cribado de cáncer de pulmón con tomografía de baja dosis de radiación (TBDR) es amplia. Sin embargo, la evidencia sobre la experiencia en España es limitada. Nuestro objetivo es presentar los resultados del programa de cribado de cáncer de pulmón más largo de España. Métodos: El Programa Internacional de Detección Precoz de Cáncer de Pulmón con TBDR de Pamplona (P-IELCAP) viene reclutando individuos de manera activa desde el año 2000 siguiendo el protocolo IELCAP. Se incluyen individuos ≥ 40 años de edad, fumadores o ex fumadores (consumo acumulado ≥ 10 paquetes-año). Los resultados se comparan con los de otros estudios europeos. Resultados: Un total de 2.989 participantes fueron reclutados hasta marzo de 2014 (73% varones), realizando una mediana de 2 (IQR 1-3) rondas de cribado por individuo. Se detectaron 60 cánceres de pulmón en 53 participantes (73% en estadio i). Adenocarcinoma fue el tipo histológico más frecuente. La proporción de prevalencia e incidencia de cáncer de pulmón fue del 1,0 y del 1,4%, respectivamente, con una tasa de detección anual de 0,41. La tasa de supervivencia a 10 años de los pacientes con cáncer de pulmón fue del 70%. La enfermedad pulmonar obstructiva crónica y el enfisema son importantes factores de riesgo para desarrollar cáncer de pulmón. Conclusiones: La experiencia del programa de cribado de cáncer de pulmón más largo de España es comparable con lo descrito en el resto de Europa y confirma la viabilidad y la eficacia del cribado mediante TBDR


Introduction and objectives: European experience regarding lung cancer screening using low-dose chest CT (LDCT) is available. However, there is limited data on the Spanish experience in this matter. Our aim is to present the results from the longest ongoing screening program in Spain. Methodology: The Pamplona International Early Lung Cancer Detection Program (P-IELCAP) is actively screening participants for lung cancer using LDCT since year 2000 following the IELCAP protocol, including spirometric assessments. Men and women, ≥ 40 years of age, current or former smokers with a tobacco history of ≥ 10 pack-years are included. Results are compared to those from other European trials. Results: A total of 2989 participants were screened until March 2014 (73% male). A median of 2 (IQR 1-3) annual screening rounds were performed. Sixty lung cancers were detected in 53 participants (73% in Stage I). Adenocarcinoma was the most frequent. The lung cancer prevalence and incidence proportion was 1.0% and 1.4%, respectively, with an annual detection rate of 0.41. The estimated 10-year survival rate among individuals with lung cancer was 70%. Chronic obstructive pulmonary disease and emphysema are important lung cancer predictors. Conclusions: The experience in Spain’s longest lung cancer screening program is comparable to what has been described in the rest of Europe, and confirms the feasibility and efficacy of lung cancer screening using LDCT


Subject(s)
Humans , Male , Female , Adult , Lung Neoplasms/diagnostic imaging , Early Detection of Cancer , Tomography, X-Ray Computed/methods , Pulmonary Disease, Chronic Obstructive/epidemiology , Pulmonary Emphysema/epidemiology , Spain/epidemiology , Adenocarcinoma , Smoking/adverse effects , Survival Rate
8.
Arch Bronconeumol ; 51(4): 169-76, 2015 Apr.
Article in English, Spanish | MEDLINE | ID: mdl-25641356

ABSTRACT

INTRODUCTION AND OBJECTIVES: European experience regarding lung cancer screening using low-dose chest CT (LDCT) is available. However, there is limited data on the Spanish experience in this matter. Our aim is to present the results from the longest ongoing screening program in Spain. METHODOLOGY: The Pamplona International Early Lung Cancer Detection Program (P-IELCAP) is actively screening participants for lung cancer using LDCT since year 2000 following the IELCAP protocol, including spirometric assessments. Men and women, ≥40 years of age, current or former smokers with a tobacco history of ≥10 pack-years are included. Results are compared to those from other European trials. RESULTS: A total of 2989 participants were screened until March 2014 (73% male). A median of 2 (IQR 1-3) annual screening rounds were performed. Sixty lung cancers were detected in 53 participants (73% in StageI). Adenocarcinoma was the most frequent. The lung cancer prevalence and incidence proportion was 1.0% and 1.4%, respectively, with an annual detection rate of 0.41. The estimated 10-year survival rate among individuals with lung cancer was 70%. Chronic obstructive pulmonary disease and emphysema are important lung cancer predictors. CONCLUSIONS: The experience in Spain's longest lung cancer screening program is comparable to what has been described in the rest of Europe, and confirms the feasibility and efficacy of lung cancer screening using LDCT.


Subject(s)
Early Detection of Cancer , Lung Neoplasms/diagnostic imaging , Tomography, X-Ray Computed/methods , Adenocarcinoma/diagnostic imaging , Adenocarcinoma/epidemiology , Adult , Aged , Carcinoma, Non-Small-Cell Lung/diagnostic imaging , Carcinoma, Non-Small-Cell Lung/epidemiology , Feasibility Studies , Female , Humans , Incidence , Kaplan-Meier Estimate , Lung Neoplasms/epidemiology , Male , Middle Aged , Prevalence , Program Evaluation , Proportional Hazards Models , Pulmonary Disease, Chronic Obstructive/epidemiology , Pulmonary Emphysema/epidemiology , Risk , Smoking/adverse effects , Spain/epidemiology , Spirometry , Survival Rate
9.
Med Phys ; 41(9): 092503, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25186412

ABSTRACT

PURPOSE: 90Y-microspheres are widely used for the radioembolization of metastatic liver cancer or hepatocellular carcinoma and there is a growing interest for imaging 90Y-microspheres with PET. The aim of this study is to evaluate the performance of a current generation PET/CT scanner for 90Y imaging and to optimize the PET protocol to improve the assessment and the quantification of 90Y-microsphere biodistribution after radioembolization. METHODS: Data were acquired on a Biograph mCT-TrueV scanner with time of flight (TOF) and point spread function (PSF) modeling. Spatial resolution was measured with a 90Y point source. Sensitivity was evaluated using the NEMA 70 cm line source filled with 90Y. To evaluate the count rate performance, 90Y vials with activity ranging from 3.64 to 0.035 GBq were measured in the center of the field of view (CFOV). The energy spectrum was evaluated. Image quality with different reconstructions was studied using the Jaszczak phantom containing six hollow spheres (diameters: 31.3, 28.1, 21.8, 16.1, 13.3, and 10.5 mm), filled with a 207 kBq/ml 90Y concentration and a 5:1 sphere-to-background ratio. Acquisition time was adjusted to simulate the quality of a realistic clinical PET acquisition of a patient treated with SIR-Spheres®. The developed methodology was applied to ten patients after SIR-Spheres® treatment acquiring a 10 min per bed PET. RESULTS: The energy spectrum showed the 90Y bremsstrahlung radiation. The 90Y transverse resolution, with filtered backprojection reconstruction, was 4.5 mm in the CFOV and degraded to 5.0 mm at 10 cm off-axis. 90Y absolute sensitivity was 0.40 kcps/MBq in the center of the field of view. Tendency of true and random rates as a function of the 90Y activity could be accurately described using linear and quadratic models, respectively. Phantom studies demonstrated that, due to low count statistics in 90Y PET acquisition, the optimal parameters for the standard OSEM+PSF reconstruction were only one iteration and a postreconstruction filter of 6 mm FWHM, for both TOF and non-TOF reconstructions. Moreover, when TOF is included, the signal to noise ratio increased and visibility achieved 100% by the experienced observers and 93.3% according to the Rose model of statistical detection. In 50% of patients, TOF allowed the visualization of 90Y radioembolized lesions not seen without TOF, confirming phantom results. Liver activity was accurately quantified, with no significant differences between reconstructed and actual delivered activity to the whole-liver [mean relative difference (10.2±14.7)%]. CONCLUSIONS: Qualitative and quantitative 90Y PET imaging improved with the introduction of TOF in a PET/CT scanner, thereby allowing the visualization of microsphere deposition in lesions not visible in non-TOF images. This technique accurately quantifies the total activity delivered to the liver during radioembolization with (90)Y-microspheres and allows dose estimation.


Subject(s)
Brachytherapy , Embolization, Therapeutic , Microspheres , Positron-Emission Tomography/methods , Yttrium Radioisotopes/pharmacokinetics , Adenocarcinoma/diagnostic imaging , Adenocarcinoma/metabolism , Adenocarcinoma/therapy , Aged , Carcinoma, Hepatocellular/diagnostic imaging , Carcinoma, Hepatocellular/metabolism , Carcinoma, Hepatocellular/therapy , Cholangiocarcinoma/diagnostic imaging , Cholangiocarcinoma/metabolism , Cholangiocarcinoma/therapy , Colorectal Neoplasms/diagnostic imaging , Colorectal Neoplasms/metabolism , Colorectal Neoplasms/therapy , Computer Simulation , Esophageal Neoplasms/diagnostic imaging , Esophageal Neoplasms/metabolism , Esophageal Neoplasms/therapy , Humans , Liver/diagnostic imaging , Liver/metabolism , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/metabolism , Liver Neoplasms/therapy , Male , Middle Aged , Neuroendocrine Tumors/diagnostic imaging , Neuroendocrine Tumors/metabolism , Neuroendocrine Tumors/therapy , Phantoms, Imaging , Positron-Emission Tomography/instrumentation , Radiation Dosage , Signal-To-Noise Ratio , Tissue Distribution , Yttrium Radioisotopes/therapeutic use
10.
Int J Cancer ; 133(9): 2157-64, 2013 Nov.
Article in English | MEDLINE | ID: mdl-23616232

ABSTRACT

Extensive screening strategies to detect occult cancer in patients with unprovoked venous thromboembolism (VTE) are complex and no benefit in terms of survival has been reported. FDG-PET/CT (2-[F-18] fluoro-2-deoxy-D-glucose positron emission tomography combined with computed tomography), a noninvasive technique for the diagnosis and staging of malignancies, could be useful in this setting. Consecutive patients ≥ 50 years with a first unprovoked VTE episode were prospectively included. Screening with FDG-PET/CT was performed 3-4 weeks after the index event. If positive, appropriate diagnostic work-up was programmed. Clinical follow-up continued for 2 years. Blood samples were collected to assess coagulation biomarkers. FDG-PET/CT was negative in 68/99 patients (68.7%), while suspicious FDG uptake was detected in 31/99 patients (31.3%). Additional diagnostic work-up confirmed a malignancy in 7/31 patients (22.6%), with six of them at early stage. During follow-up, two patients with negative FDG-PET/CT were diagnosed with cancer. Sensitivity (S), positive (PPV) and negative predictive values (NPV) of FDG-PET/CT as single tool for the detection of occult malignancy were 77.8% (95% CI: 0.51-1), 22.6% (95% CI: 0.08-0.37) and 97.1% (95% CI: 0.93-1), respectively. Median tissue factor (TF) activity in patients with occult cancer was 5.38 pM vs. 2.40 pM in those without cancer (p = 0.03). Limitation of FDG-PET/CT screening to patients with TF activity > 2.8 pM would improve the PPV to 37.5% and reduce the costs of a single cancer diagnosis from 20,711€ to 11,670€. FDG-PET/CT is feasible for the screening of occult cancer in patients with unprovoked VTE, showing high S and NPV. The addition of TF activity determination may be useful for patient selection.


Subject(s)
Blood Coagulation Factors/analysis , Early Detection of Cancer , Fluorodeoxyglucose F18 , Neoplasms, Unknown Primary/diagnosis , Positron-Emission Tomography , Tomography, X-Ray Computed , Venous Thromboembolism/complications , Aged , Anticoagulants/therapeutic use , Biomarkers, Tumor/blood , Female , Follow-Up Studies , Humans , Male , Neoplasms, Unknown Primary/etiology , Neoplasms, Unknown Primary/metabolism , Prognosis , Prospective Studies , Radiopharmaceuticals , Venous Thromboembolism/drug therapy
11.
J Oncol ; 2012: 710561, 2012.
Article in English | MEDLINE | ID: mdl-22973310

ABSTRACT

Molecular imaging of breast cancer has undoubtedly permitted a substantial development of the overall diagnostic accuracy of this malignancy in the last years. Accurate tumour staging, design of individually suited therapies, response evaluation, early detection of recurrence and distant lesions have also evolved in parallel with the development of novel molecular imaging approaches. In this context, positron emission tomography (PET) can be probably seen as the most interesting molecular imaging technology with straightforward clinical application for such purposes. Dozens of radiotracers for PET imaging of breast cancer have been tested in laboratory animals. However, in this review we shall focus mainly in the smaller group of PET radiopharmaceuticals that have lead through into the clinical setting. PET imaging can be used to target general metabolic phenomena related to tumoural transformation, including glucose metabolism and cell proliferation, but can also be directed to specific hormone receptors that are characteristic of the breast cancer cell. Many other receptors and transport molecules present in the tumour cells could also be of interest for imaging. Furthermore, molecules related with the tumour microenvironment, tumour induced angiogenesis or even hypoxia could also be used as molecular biomarkers for breast cancer imaging.

12.
Mol Imaging Biol ; 12(2): 210-7, 2010 Apr.
Article in English | MEDLINE | ID: mdl-19543774

ABSTRACT

PURPOSE: The purpose of this study was to evaluate a dual tracer 2-deoxy-2-[F-18]fluoro-D: -glucose (FDG) and (11)C-choline positron emission tomography (PET) protocol in the detection of biochemical prostate cancer relapse. PROCEDURES: Seventy-three patients (median Prostate Specific Antigen (PSA) Test value 2.7 ng/ml (1.1-5.4)) after radical treatment. PET scans were performed by means of a ECAT-Exact HR+ in the first 18 patients and in a PET/computed tomography Biograph II in the remaining 55 patients. RESULTS: The sensitivity of (11)C-choline and FDG was 60.6% and 31%. In PSA levels over 1.9 ng/ml, sensitivity increased to 80% and 40%, respectively. In the group receiving adjuvant hormone therapy, the diagnostic yields were 71.2% and 43%, respectively. While (11)C-choline-PET could not differentiate well and poorly differentiated Gleason score patients, FDG-PET results were almost significant (p = 0.058). CONCLUSIONS: A PSA value higher than 1.9 ng/ml determines a significant increase in the diagnostic yield. Adjuvant hormonotherapy has no influence on the PET results. FDG has a better correlation with the Gleason score than (11)C-choline.


Subject(s)
Choline , Fluorodeoxyglucose F18 , Neoplasm Recurrence, Local/diagnostic imaging , Positron-Emission Tomography , Prostate-Specific Antigen/blood , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/therapy , Adult , Aged , Carbon Radioisotopes , Humans , Male , Middle Aged , Prostatic Neoplasms/blood
13.
Cases J ; 2: 6384, 2009 Jun 26.
Article in English | MEDLINE | ID: mdl-19829800

ABSTRACT

The mandible is a rare site for the occurrence of primary bone lymphoma (PBL), a non-Hodgkin lymphoma. We report herein a case of an incidentally diagnosed thyroid incidentaloma by (18)Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in a patient with a previous diagnosis of PBL. Therapeutic options are reviewed and discussed.

14.
J Nucl Cardiol ; 9(6): 581-6, 2002.
Article in English | MEDLINE | ID: mdl-12466781

ABSTRACT

BACKGROUND: We aimed to assess whether atropine administration is safe and feasible in patients unable to reach the minimal heart rate (HR) required (80% of age-predicted HR) in myocardial scintigraphic studies after exercise stress testing (EST). METHODS AND RESULTS: We studied 108 patients who underwent myocardial perfusion scintigraphy after EST; 0.5 mg of atropine was administered to those showing signs of fatigue before reaching minimal HR (group A, n = 44). The scintigraphic results for group A were compared with those of patients who spontaneously achieved minimal HR (group B, n = 64). Coronary angiographic results, if available, and clinical follow-up were also compared. In group A, atropine increased HR by 13.7 +/- 7.4 beats/min. The percentage of maximal age-related HR achieved was 83.3% +/- 7.5%; 74% achieved minimal HR. No major adverse effects occurred. When groups A and B were compared, baseline and peak HR, rate pressure product, and maximal metabolic equivalents achieved were higher in group B. There were no differences in number of perfusion studies positive for ischemia (group A, 26/44, and group B, 30/64; P =.2), coronary lesions, or clinical follow-up. CONCLUSIONS: Atropine added to EST in patients who cannot achieve their 80% age-related HR is a safe and potentially useful method for myocardial perfusion studies.


Subject(s)
Atropine/adverse effects , Exercise Test , Heart Rate/drug effects , Myocardial Ischemia/diagnostic imaging , Thallium , Tomography, Emission-Computed, Single-Photon/methods , Feasibility Studies , Female , Heart/diagnostic imaging , Humans , Male , Radiopharmaceuticals , Reproducibility of Results , Sensitivity and Specificity , Stress, Physiological/chemically induced
SELECTION OF CITATIONS
SEARCH DETAIL
...