Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 91(4): 043106, 2020 Apr 01.
Article in English | MEDLINE | ID: mdl-32357691

ABSTRACT

Sandia's Z Pulsed Power Facility is able to dynamically compress matter to extreme states with exceptional uniformity, duration, and size, which are ideal for investigating fundamental material properties of high energy density conditions. X-ray diffraction (XRD) is a key atomic scale probe since it provides direct observation of the compression and strain of the crystal lattice and is used to detect, identify, and quantify phase transitions. Because of the destructive nature of Z-Dynamic Material Property (DMP) experiments and low signal vs background emission levels of XRD, it is very challenging to detect a diffraction signal close to the Z-DMP load and to recover the data. We have developed a new Spherical Crystal Diffraction Imager (SCDI) diagnostic to relay and image the diffracted x-ray pattern away from the load debris field. The SCDI diagnostic utilizes the Z-Beamlet laser to generate 6.2-keV Mn-Heα x rays to probe a shock-compressed material on the Z-DMP load. A spherically bent crystal composed of highly oriented pyrolytic graphite is used to collect and focus the diffracted x rays into a 1-in. thick tungsten housing, where an image plate is used to record the data.

2.
Rev Sci Instrum ; 89(10): 10G113, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399826

ABSTRACT

Recent breakthroughs in the fabrication of small-radii Wolter optics for astrophysics allow high energy density facilities to consider such optics as novel x-ray diagnostics at photon energies of 15-50 keV. Recently, the Lawrence Livermore National Laboratory, Sandia National Laboratories (SNL), the Smithsonian Astrophysical Observatory, and the NASA Marshall Space Flight Center jointly developed and fabricated the first custom Wolter microscope for implementation in SNL's Z machine with optimized sensitivity at 17.5 keV. To achieve spatial resolution of order 100-200 microns over a field of view of 5 × 5 × 5 mm3 with high throughput and narrow energy bandpass, the geometry of the optic and its multilayer required careful design and optimization. While the geometry mainly influences resolution and the field of view of the diagnostic, the mirror coating determines the spectral response and throughput. Here we outline the details of the design and fabrication process for the first multilayer-coated Wolter I optic for SNL's Z machine (Z Wolter), including its W/Si multilayer, and present results of raytrace simulations completed to predict and verify the performance of the optic.

3.
Rev Sci Instrum ; 89(10): 10G115, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399891

ABSTRACT

A new Wolter x-ray imager has been developed for the Z machine to study the emission of warm (>15 keV) x-ray sources. A Wolter optic has been adapted from observational astronomy and medical imaging, which uses curved x-ray mirrors to form a 2D image of a source with 5 × 5 × 5 mm3 field-of-view and measured 60-300-µm resolution on-axis. The mirrors consist of a multilayer that create a narrow bandpass around the Mo Kα lines at 17.5 keV. We provide an overview of the instrument design and measured imaging performance. In addition, we present the first data from the instrument of a Mo wire array z-pinch on the Z machine, demonstrating improvements in spatial resolution and a 350-4100× increase in the signal over previous pinhole imaging techniques.

4.
N Engl J Med ; 314(3): 138-44, 1986 Jan 16.
Article in English | MEDLINE | ID: mdl-3455748

ABSTRACT

We assessed the relation of risk factors for cardiovascular disease to early atherosclerotic lesions in the aorta and coronary arteries in 35 persons (mean age at death, 18 years). Aortic involvement with fatty streaks was greater in blacks than in whites (37 vs. 17 percent, P less than 0.01). However, aortic fatty streaks were strongly related to antemortem levels of both total and low-density lipoprotein cholesterol (r = 0.67, P less than 0.0001 for each association), independently of race, sex, and age, and were inversely correlated with the ratio of high-density lipoprotein cholesterol to low-density plus very-low-density lipoprotein cholesterol (r = -0.35, P = 0.06). Coronary-artery fatty streaks were correlated with very-low-density lipoprotein cholesterol (r = 0.41, P = 0.04). Mean systolic blood-pressure levels also tended to be higher in the four subjects with coronary-artery fibrous plaques than in those without them: 112 mm Hg as compared with 104 (P = 0.09). These results document the importance of risk-factor levels to early anatomical changes in the aorta and coronary arteries. The progression of fatty streaks to fibrous plaques is uncertain, but these data suggest that a rational approach to the prevention of cardiovascular disease should begin early in life.


Subject(s)
Arteriosclerosis/diagnosis , Blood Pressure , Lipoproteins/blood , Adolescent , Adult , Age Factors , Aorta/pathology , Arteriosclerosis/blood , Arteriosclerosis/pathology , Black People , Child , Child, Preschool , Cholesterol/blood , Cholesterol, HDL/blood , Cholesterol, LDL/blood , Cholesterol, VLDL , Coronary Disease/blood , Coronary Disease/diagnosis , Coronary Disease/pathology , Coronary Vessels/pathology , Female , Humans , Lipoproteins, VLDL/blood , Louisiana , Male , Risk , Sex Factors , White People
7.
Vet Rec ; 103(11): 248, 1978 Sep 09.
Article in English | MEDLINE | ID: mdl-716176
SELECTION OF CITATIONS
SEARCH DETAIL
...