1.
Emerg Med J ; 34(4): 256-263, 2017 Apr.
Article in English | MEDLINE | ID: mdl-27539585

ABSTRACT

Organ transplantation is associated with improved outcomes for some patients with end-stage organ failure; however, the number of patients awaiting a transplant exceeds the available organs. Recently, an extended role has been proposed for EDs in the recognition and management of potential donors. The present review presents an illustrative case report and considers current transplantation practice in the UK. Ethical and legal considerations, the classification of deceased donors and future developments promising greater numbers of organs are discussed.


Subject(s)
Emergency Service, Hospital/trends , Tissue Donors/psychology , Tissue and Organ Procurement/methods , Emergency Service, Hospital/organization & administration , Emergency Service, Hospital/statistics & numerical data , Humans , Tissue Donors/statistics & numerical data , Tissue Donors/supply & distribution , Tissue and Organ Procurement/statistics & numerical data , United Kingdom , Workforce
2.
Cochrane Database Syst Rev ; (3): CD009694, 2014 Mar 31.
Article in English | MEDLINE | ID: mdl-24683063

ABSTRACT

BACKGROUND: The diagnosis of death using neurological criteria (brain death) has profound social, legal and ethical implications. The diagnosis can be made using standard clinical tests examining for brain function, but in some patient populations and in some countries additional tests may be required. Computed tomography (CT) angiography, which is currently in wide clinical use, has been identified as one such test. OBJECTIVES: To assess from the current literature the sensitivity of CT cerebral angiography as an additional confirmatory test for diagnosing death using neurological criteria, following satisfaction of clinical neurological criteria for brain death. SEARCH METHODS: We performed comprehensive literature searches to identify studies that would assess the diagnostic accuracy of CT angiography (the index test) in cohorts of adult patients, using the diagnosis of brain death according to neurological criteria as the target condition. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2012, Issue 5) and the following databases from January 1992 to August 2012: MEDLINE; EMBASE; BNI; CINAHL; ISI Web of Science; BioMed Central. We also conducted searches in regional electronic bibliographic databases and subject-specific databases (MEDION; IndMed; African Index Medicus). A search was also conducted in Google Scholar where we reviewed the first 100 results only. We handsearched reference lists and conference proceedings to identify primary studies and review articles. Abstracts were identified by two authors. Methodological assessment of studies using the QUADAS-2 tool and further data extraction for re-analysis were performed by three authors. SELECTION CRITERIA: We included in this review all large case series and cohort studies that compared the results of CT angiography with the diagnosis of brain death according to neurological criteria. Uniquely, the reference standard was the same as the target condition in this review. DATA COLLECTION AND ANALYSIS: We reviewed all included studies for methodological quality according to the QUADAS-2 criteria. We encountered significant heterogeneity in methods used to interpret CT angiography studies and therefore, where possible, we re-analysed the published data to conform to a standard radiological interpretation model. The majority of studies (with one exception) were not designed to include patients who were not brain dead, and therefore overall specificity was not estimable as part of a meta-analysis. Sensitivity, confidence and prediction intervals were calculated for both as-published data and as re-analysed to a standardized interpretation model. MAIN RESULTS: Ten studies were found including 366 patients in total. We included eight studies in the as-published data analysis, comprising 337 patients . The methodological quality of the studies was overall satisfactory, however there was potential for introduction of significant bias in several specific areas relating to performance of the index test and to the timing of index versus reference tests. Results demonstrated a sensitivity estimate of 0.84 (95% confidence interval (CI) 0.69 to 0.93). The 95% approximate prediction interval was very wide (0.34 to 0.98). Data in three studies were available as a four-vessel interpretation model and the data could be re-analysed to a four-vessel interpretation model in a further five studies, comprising 314 patient events. Results demonstrated a similar sensitivity estimate of 0.85 (95% CI 0.77 to 0.91) but with an improved 95% approximate prediction interval (0.56 to 0.96). AUTHORS' CONCLUSIONS: The available evidence cannot support the use of CT angiography as a mandatory test, or as a complete replacement for neurological testing, in the management pathway of patients who are suspected to be clinically brain dead. CT angiography may be useful as a confirmatory or add-on test following a clinical diagnosis of death, assuming that clinicians are aware of the relatively low overall sensitivity. Consensus on a standard radiological interpretation protocol for future published studies would facilitate further meta-analysis.


Subject(s)
Brain Death/diagnosis , Cerebral Angiography/methods , Tomography, X-Ray Computed/methods , Cohort Studies , Humans , Sensitivity and Specificity