Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
J Anal Toxicol ; 39(2): 118-25, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25492522

ABSTRACT

Fentanyl is a synthetic narcotic anesthetic ∼80-100 times more potent than morphine. Owing to the potential for its abuse, the drug may be included in a forensic toxicology work-up, which requires fast, precise and accurate measurements. Here, the stability of fentanyl was assessed when stored at three different temperatures (-20, 4 and 25°C) in synthetic urine. Stability at those three temperatures was demonstrated over 12 weeks upon analysis by gas chromatography-mass spectrometry with a deuterated internal standard (fentanyl-D5) utilizing three different extraction techniques: liquid-liquid extraction (LLE), solid-phase extraction and dispersed liquid-liquid microextraction (DLLME). The DLLME method was then optimized before use in the analysis of fentanyl in urine samples obtained from autopsy cases at the El Paso County Coroner's Office. Accuracy of the DLLME method was assessed by completing spike and recovery studies at three different fortification levels (10, 100 and 250 ng/mL) with excellent recovery (89.9-102.6%). The excellent comparability between DLLME and LLE is demonstrated (Bland-Altman difference plot with a mean difference of 4.9 ng/mL) and the use of this methodology in the analysis of forensically relevant samples is discussed.


Subject(s)
Fentanyl/urine , Gas Chromatography-Mass Spectrometry/methods , Liquid Phase Microextraction/methods , Drug Stability , Fentanyl/chemistry , Humans
2.
Heart Lung Circ ; 22(8): 634-41, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23465291

ABSTRACT

BACKGROUND: Graphical Statistical Process Control (SPC) tools have been shown to promptly identify significant variations in clinical outcomes in a range of health care settings. We explored the application of these techniques to quantitatively inform the routine cardiac surgical (CAS) morbidity and mortality (M&M) review processes at a single site. METHODS: Baseline clinical and procedural data relating to 5265 consecutive cardiac surgical procedures, performed at St Andrew's War Memorial Hospital (SAWMH) between the 1st January 2003 and the 30th April 2012, were retrospectively evaluated. A range of appropriate clinical outcome indicators (COIs) were developed and evaluated using a combination of Cumulative Sum charts, Exponentially Weighted Moving Average charts and Funnel Plots. Charts were updated regularly and discussed at the cardiac surgery unit's bi-monthly M&M meetings. Risk adjustment (RA) for the COIs was developed and validated for incorporation into the charts to improve monitoring performance. RESULTS: Discrete and aggregated measures, including blood product/reoperation, major acute post-procedural complications, cardiopulmonary bypass duration and Length of Stay/Readmission < 28 days have proved to be valuable measures for monitoring outcomes. Instances of variation in performance identified using the charts were examined thoroughly and could be related to changes in clinical practice (e.g. antifibrinolytic use) as well as differences in individual operator performance (in some instances, driven by case mix). CONCLUSIONS: SPC tools can promptly detect meaningful changes in clinical outcome thereby allowing early intervention to address altered performance. Careful interpretation of charts for group and individual operators has proven helpful in detecting and differentiating systemic versus individual variation.


Subject(s)
Cardiac Surgical Procedures , Databases, Factual , Models, Biological , Monitoring, Physiologic , Female , Humans , Male , Retrospective Studies
3.
Heart Lung Circ ; 22(2): 92-9, 2013 Feb.
Article in English | MEDLINE | ID: mdl-23063751

ABSTRACT

BACKGROUND: Graphical Statistical Process Control (SPC) tools have been shown to promptly identify significant variations in clinical outcomes in a range of health care settings. We explored the application of these techniques to qualitatively inform the routine cardiac surgical morbidity and mortality (M&M) review process at a single site. METHODS: Baseline clinical and procedural data relating to 4774 consecutive cardiac surgical procedures, performed between the 1st January 2003 and the 30th April 2011, were retrospectively evaluated. A range of appropriate performance measures and benchmarks were developed and evaluated using a combination of CUmulative SUM (CUSUM) charts, Exponentially Weighted Moving Average (EWMA) charts and Funnel Plots. Charts have been discussed at the unit's routine M&M meetings. Risk adjustment (RA) based on EuroSCORE has been incorporated into the charts to improve performance. RESULTS: Discrete and aggregated measures, including Blood Product/Reoperation, major acute post-procedural complications and Length of Stay/Readmission<28 days have proved to be usable measures for monitoring outcomes. Monitoring trends in minor morbidities provides a valuable warning of impending changes in significant events. Instances of variation in performance have been examined and could be related to differences in individual operator performance via individual operator curves. CONCLUSION: SPC tools facilitate near "real-time" performance monitoring allowing early detection and intervention in altered performance. Careful interpretation of charts for group and individual operators has proven helpful in detecting and differentiating systemic vs. individual variation.


Subject(s)
Coronary Artery Bypass/statistics & numerical data , Coronary Artery Bypass/standards , Outcome Assessment, Health Care , Postoperative Hemorrhage/surgery , Quality Improvement , Benchmarking , Blood Transfusion/statistics & numerical data , Cardiac Tamponade/surgery , Clinical Competence , Coronary Artery Bypass/adverse effects , Humans , Length of Stay/statistics & numerical data , Patient Readmission/statistics & numerical data , Reoperation , Retrospective Studies , Risk Adjustment , Treatment Outcome
4.
Intensive Care Med ; 31(8): 1087-94, 2005 Aug.
Article in English | MEDLINE | ID: mdl-16012807

ABSTRACT

OBJECTIVE: To compare case-mix, health care practices, and outcome in obstetric ICU admissions in inner-city teaching hospitals in economically developed and developing countries. DESIGN: Retrospective study. SETTING: Ben Taub General Hospital (BTGH), Houston, Texas, and King Edward Memorial Hospital (KEMH), Mumbai, India. PATIENTS: Women admitted during pregnancy or 6 weeks postpartum between 1992 and 2001. MEASUREMENTS AND RESULTS: Patients from BTGH (n=174) and KEMH (n=754) had comparable age, number of organs affected, incidence of medical disorders (30%), liver dysfunction, and thrombocytopenia. Fewer KEMH patients received prenatal care (27 vs 86%) and came to hospital within 24 h of onset of symptoms (60 vs 90%). They had higher APACHE II scores (median 16 vs 10), greater incidence of neurological (63 vs 36%), renal (50 vs 37%), and cardiovascular dysfunction (39 vs 29%). Severe malaria, viral hepatitis, cerebral venous thrombosis, and poisoning were common medical disorders. The BTGH group had higher incidence of respiratory dysfunction (59 vs 46%) and disseminated intravascular coagulation (40 vs 23%), placental anomalies, HELLP syndrome, chorioamnionitis, peripartum cardiomyopathy, puerperal sepsis, urinary infection, bacteremia, substance abuse, and asthma. More BTGH patients required mechanical ventilation and blood component therapy, whereas more KEMH patients needed dialysis. Of BTGH patients, 78.2% were delivered by cesarean section (vs 15.4%). Maternal (2.3 vs 25%) and fetal (13 vs 51%) mortality were lower in BTGH patients. CONCLUSIONS: There were marked differences in medical diseases, organ failure, and intensive care needs. Higher mortality in the Indian ICU may be due to difference in case mix, inadequate prenatal care, delay in reaching hospital, and greater severity of illness.


Subject(s)
Critical Illness , Pregnancy Complications/therapy , Adult , Critical Care/economics , Female , Gestational Age , Hospitals, Public , Humans , India , Intensive Care Units , Multiple Organ Failure/etiology , Multiple Organ Failure/therapy , Pregnancy , Pregnancy Complications/classification , Pregnancy Complications/diagnosis , Retrospective Studies , Thrombocytopenia/etiology , Thrombocytopenia/therapy , Treatment Outcome , United States
5.
Ann Thorac Surg ; 79(3): 757-66, 2005 Mar.
Article in English | MEDLINE | ID: mdl-15734372

ABSTRACT

BACKGROUND: This truly stentless porcine valve is composite, without Dacron, and implanted supra-annularly. Ten-year analysis with magnetic resonance imaging is presented. METHODS: From 1992 to 2002, 402 patients (mean 73.5 years) had aortic valve replacement. Associated procedures were required in 252 patients (63%). Serial echoes provided 1340 studies. Clinical follow-up was 100%. Magnetic resonance imaging focused on aortic annulus extensibility. RESULTS: The 30-day mortality was 0.99% (4 deaths). Morbidity comprised thromboembolism (40 patients including 18 patients with permanent strokes); endocarditis (9 patients); and reoperation (9 patients [periprosthetic leak, 2; endocarditis, 5; technical needle damage, 1; and structural degeneration, 1]). Of 402 valves more than 10 years, five valves were explanted, one only for structural failure. Except for endocarditis (2 patients), no late deaths (69 patients, 1.5 months to 5.7 years) were valve related. Echocardiography demonstrated low gradients with good orifice areas, excellent ventricular regression (p = 0.0001 preoperative and postoperative comparisons) and late incompetence (mild in 45 patients and moderate in 9 patients). No living patient has severe incompetence. Magnetic resonance imaging demonstrated the annulus 'expanding and relaxing' throughout the cardiac cycle, the mean increase in cross-sectional area being 37%, resembling normal aortic root dynamics. CONCLUSIONS: Elderly patients received this hemodynamically acceptable valve with its simple, supra-annular implantation and satisfactory mid-term morbid-free lifestyle to 10 years maximum follow-up. With only one structural failure, restoration of valve annular extensibility may have a favorable influence on long-term durability.


Subject(s)
Aortic Valve/surgery , Bioprosthesis , Heart Valve Prosthesis , Actuarial Analysis , Aged , Aged, 80 and over , Child , Child, Preschool , Female , Follow-Up Studies , Heart Valve Prosthesis/adverse effects , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Postoperative Complications/epidemiology , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...