ABSTRACT

BACKGROUND: The advantageous design of the Cryolife-O'Brien stentless porcine aortic valve permits specific quick, easy, supravalvular implantation using single layer continuous 3-0 polypropylene suture. The advantages, contraindications, and implantation errors to avoid are detailed. The use of this valve for aortic valve replacement in the elderly population has been directed to proving its efficacy and establishing its grounds for durability while maintaining all of the advantages of a stentless tissue valve. METHODS: From December 1992 to September 1998, this valve was used in 240 patients (mean age 73 years: 15% > 80 years), 45% receiving associated coronary artery grafting (2.4 grafts per patient). Left ventricular (LV) myomectomy was necessary in 12% of patients. Detailed postoperative follow-up (100%) analysis included 650 serial echocardiographic studies. RESULTS: The 30-day mortality was low at 1.2% (3 deaths of 240 elderly patients). Ten patients had late mortality (1.5 months to 5 years), all nonvalve related. No structural failure and one only explant for endocarditis have occurred. Echocardiographic analyses have shown low mean transvalvular gradients in relationship to time (8.18 mmHg at 18 months) and to valve size (8.52 mmHg for a 23-mm host aortic annulus). Incompetence has been zero or a trace in 97% of the patients at 21/2 years. No patient over the 6 years shows valve deterioration. CONCLUSION: Six years of experience with this stentless valve in 240 elderly patients has revealed the many advantages of this safe, composite, and truly stentless device that is assembled without the need for Dacron support. Excellent sustained hemodynamics with low gradients, minimal regurgitation, and a good effective orifice have been coupled with low immediate mortality, no intrinsic valve failure, and one explant for endocarditis. Marked LV regression and minimal late valve-related complications confirm the safety and advantages of this stentless valve.


Subject(s)
Bioprosthesis , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Aged , Aged, 80 and over , Animals , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Cardiac Output , Echocardiography , Female , Follow-Up Studies , Heart Valve Diseases/mortality , Heart Valve Diseases/physiopathology , Heart Valve Prosthesis Implantation/mortality , Humans , Male , Middle Aged , Retrospective Studies , Survival Rate , Suture Techniques , Swine , Transplantation, Heterologous
3.
Jpn Circ J ; 61(8): 682-6, 1997 Aug.
Article in English | MEDLINE | ID: mdl-9276773

ABSTRACT

The CryoLife-O'Brien stentless valve is a composite trileaflet porcine aortic valve. It is assembled from 3 non-coronary leaflets and has no foreign material support. It is therefore truly stentless. From December 1992 to January 1996, 118 patients with aortic valve replacement had a CryoLife-O'Brien stentless valve inserted at the Prince Charles Hospital, Brisbane. The mean age was 73 years (range 59-89) and 54% were men. Most patients had aortic stenosis secondary to a calcific degenerative valve. Follow-up is 100% with hematological and echocardiographic studies before discharge, at 6 months, and at 12-18 months. Five deaths (2 early and 3 late) have occurred and morbidity includes 3 strokes, 1 peripheral embolism, 3 perivalvular leaks, and 1 patient with late endocarditis. Valve performance has been good, with low transvalvular gradients and only a trace or no regurgitation in over 95% of patients after 18 months. No structural deterioration or hemolysis has occurred. Echocardiographic surveillance confirms a very effective central orifice. Short-term results show that the overall performance of the CryoLife-O'Brien stentless valve has been very satisfactory, with low mortality and morbidity in this elderly group of patients. The benefits include the absence of prosthetic material, wide leaflet coaptation, and a quick and easy insertion. Long-term anticoagulation is not necessary. It is particularly suitable for elderly patients with a symmetrical aortic root.


Subject(s)
Bioprosthesis/instrumentation , Heart Valve Prosthesis/instrumentation , Aged , Aged, 80 and over , Animals , Aortic Valve/surgery , Aortic Valve Insufficiency/etiology , Bioprosthesis/adverse effects , Bioprosthesis/mortality , Female , Follow-Up Studies , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis/mortality , Humans , Male , Middle Aged , Prosthesis Design , Swine
SELECTION OF CITATIONS
SEARCH DETAIL
...