Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Surg Case Rep ; 8C: 68-70, 2015.
Article in English | MEDLINE | ID: mdl-25635600

ABSTRACT

INTRODUCTION: Carotid angioplasty and stenting (CAS) has been demonstrated to be safe and an acceptable alternative to surgery. Stent malpositioning can occur during the maneuvers of delivering; technical errors can lead to proximal or distal slipping of the stent that needs the placement of additional pieces. PRESENTATION OF CASE: We describe the case of a postoperative dislocation of a carotid stent that happened 1 year after placement. After the first ultrasound control confirmed the correct position of the Stent the following one, executed 9 months later, showed a severe restenosis due to a proximal dislocation of the stent. The problem was solved with the positioning of a further one more distally. DISCUSSION: We observe the possibility of Carotid Wallstent shortening during the implant due to an incorrect placement or sizing, but a delayed displacement is a rare complication that, we highlight, can occur after CAS and that needs to be considered at the moment of the preoperative planning. CONCLUSION: After CAS a closed ultrasound follow up is advisable for a long time in order to detect unexpected complications.

2.
Int J Surg Case Rep ; 3(6): 218-21, 2012.
Article in English | MEDLINE | ID: mdl-22466115

ABSTRACT

INTRODUCTION: It is now becoming increasingly difficult to accept that some patients are not suitable for surgery due to high surgical risk. The continuous technological progress, in the endovascular field in particular, are urging surgeons to put the limit even more forth. PRESENTATION OF CASE: We are going to describe an endovascular option used to treat an infrarenal aortic aneurysm where the diameter of the iliac vessels couldn't allow the use of any device available on the market. Three covered AdvantaV12 stents were placed in series in the aorta to build the endoprosthesis body and two Bard Fluency 8mm×60mm were then placed in a "kissing way" into the common iliac arteries like legs. DISCUSSION: Continuous technological progress, particularly in the endovascular field, is driving surgeons to push the limits even further. Nevertheless, some things still seem not to be possible, but in comparison to traditional surgery where all is well demonstrated and documented, the endovascular approach is still a young discipline and allows us to try to find new solutions. CONCLUSION: We can therefore assert that in exceptional circumstances, an aortic endoprosthesis can be built inside the aortic lumen using covered stents.

3.
Acta Chir Belg ; 102(4): 238-47, 2002 Aug.
Article in English | MEDLINE | ID: mdl-12244902

ABSTRACT

UNLABELLED: Vascular prosthetic graft infection remains a major surgical challenge. Prevention of risk factors and antibiotic therapy can reduced but not eradicate it. Management of infected vascular grafts depends on several factors, including the location of the infected prosthesis, the extent of infection, and the underlying micro-organism. Classic treatment consists of extra-anatomic bypass grafting. The disappointing results due to the high mortality and amputation rate have kindled interest in alternative approaches, such as in situ reconstruction with antibiotic-bonded prostheses, autogenous veins or arterial allografts. PURPOSE: We focused on the treatment of aortic graft infection by means of both fresh and cryopreserved arterial allograft. Here, the experience of the Italian Collaborative Vascular Homograft Group is reported. METHODS: Between March 1994 and December 2000 seventy-nine patients with aortic graft infection were treated. The results of 68 patients are analysed. Eleven patients were treated with fresh, and 57 with cryopreserved homograft. Emergency surgical procedures were performed in 12 patients (17%). Aortoenteric fistula was diagnosed in 22 patients. The mean interval between the first procedure and the insertion of a homograft for patients with infected aortic graft was 3 years (range 1-15). The mean duration of follow-up was 30 months (range 1-68). Clinical and duplex scanning evaluation were routinely performed. Computer tomography (CT), magnetic resonance (MR), or arteriography were performed on the basis of duplex scanning results. RESULTS: The analysis was performed on 68 cases for which there were sufficient reliable data. Eleven deaths occurred during the early postoperative period (30 days), a mortality rate of 16%. There were also seventeen late deaths, a mortality rate of 25%. Eleven patients had graft occlusion; six cases were successfully treated with thrombectomy. In three cases leg amputation was necessary. The results of fresh and cryopreserved homografts were compared. No significant differences of early postoperative mortality, late mortality, homograft-related mortality, graft failure were observed. The presence of aortoenteric fistula is a negative predicting factor of perioperative early mortality, which causes a rapid decline in the survival curve. Thirty-six months after the surgery the actuarial survival of the patients was 57% and the actuarial patency of the allograft was 41%. CONCLUSION: No significant difference in terms of clinical outcome was observed when using fresh, rather than cryopreserved homografts. The only factor that significantly influenced the survival rate appeared to be the aorto-enteric fistula.


Subject(s)
Bacterial Infections/epidemiology , Bacterial Infections/microbiology , Blood Vessel Prosthesis/adverse effects , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/microbiology , Anti-Bacterial Agents , Bacterial Infections/drug therapy , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/methods , Combined Modality Therapy , Cryopreservation , Drug Therapy, Combination/administration & dosage , Female , Graft Rejection , Graft Survival , Gram-Negative Bacteria/isolation & purification , Gram-Positive Bacteria/isolation & purification , Humans , Incidence , Male , Prognosis , Prosthesis-Related Infections/physiopathology , Prosthesis-Related Infections/therapy , Reoperation , Risk Assessment , Transplantation, Homologous , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...