Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
7.
Int J Fertil Womens Med ; 42(5): 311-8, 1997.
Article in English | MEDLINE | ID: mdl-9406837

ABSTRACT

OBJECTIVE: To test the hypothesis that treating dysfunctional uterine bleeding by automated application of electrothermal energy to the uterine cavity, with precise regional control, might yield results equivalent to those reported for hysteroscopically directed laser and electrosurgical endometrial ablations. MATERIALS AND METHODS: Patients with life style compromising menorrhagia, referred to six gynecologic surgical centers for hysterectomy or endometrial ablation, were admitted to the study if they had normal cervical cytology, a benign endometrial biopsy, no defined cause for their bleeding, and consented to participate in the evaluation of a newly developed Vesta DUB Treatment System. The device consists of a silicone-inflatable electrode carrier to be inserted into the uterine cavity and a controller to monitor and distribute current from a matched electrosurgical generator. Treatment involved a 3-minute or shorter warm-up period and a 4-minute treatment phase. RESULTS: Three- to 24-month follow-up data were available for 187 patients, with a mean follow-up of 14.8 months. The amenorrhea rate was 38%. Bleeding was reduced in 95% of patients. Actuarially, 88 +/- 3% of patients should expect to be free of menorrhagia, dissatisfaction, or need for a second procedure out to 24 months. CONCLUSIONS: The unique regional feed-back control offered by this system causes thorough, evenly distributed, thermal destruction 4-5 mm into the myometrium that reduces bleeding with durability equivalent to published reports of hysteroscopic endometrial ablation.


Subject(s)
Catheter Ablation/methods , Endometrium/surgery , Uterine Hemorrhage/surgery , Adult , Biopsy , Catheter Ablation/adverse effects , Catheter Ablation/instrumentation , Endometrium/cytology , Female , Follow-Up Studies , Humans , Hysteroscopy , Menorrhagia/complications , Menorrhagia/diagnosis , Menorrhagia/surgery , Middle Aged , Postoperative Complications , Recurrence , Treatment Outcome , Uterine Hemorrhage/diagnosis , Uterine Hemorrhage/etiology
8.
J Am Assoc Gynecol Laparosc ; 3(3): 403-7, 1996 May.
Article in English | MEDLINE | ID: mdl-9050663

ABSTRACT

The VestaBlate system uses a multielectrode intrauterine balloon as a device to create effective and safe endometrial ablation (EA). The surface of the distensible balloon is impregnated with thermistors and thin, platelike electrodes. It is designed to deliver low-power electroenergy to the endometrium. Unlike the resectoscope techniques that require nonelectrolytic fluids for uterine distention, moving electrodes at high power outputs, and other variables that are operator dependent, the VestaBlate is computer controlled using a standard type electrosurgical generator. A respiratory enzyme stain, nitroblue tetrazoleum, was used to determine the extent and depth of tissue necrosis to a myometrial depth of 2 to 4 mm with uniform destruction of tissue with power setting at 45 W for a 4-minute application of energy. Sixty-nine patients have been treated, with 45 followed for at least 3 to 9 months. The amenorrhea rate is 40%; the oligomenorhea-hypomenorrhea rate is 49%.


Subject(s)
Electrosurgery/instrumentation , Menorrhagia/surgery , Electrodes , Endometrium , Female , Humans
SELECTION OF CITATIONS