Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Infus Nurs ; 47(3): 175-181, 2024.
Article in English | MEDLINE | ID: mdl-38744242

ABSTRACT

Due to low compliance by bedside nursing with a central line-associated bloodstream infection (CLABSI) prevention bundle and increased CLABSI rates, a mandatory re-education initiative at a 1200-bed university-affiliated hospital was undertaken. Despite this, 2 units, housing high-risk immunocompromised patients, continued to experience increased CLABSI rates. A quality improvement before-after project design in these units replaced bedside nursing staff with 2 nurses from the vascular access team (VAT) to perform central vascular access device (CVAD) dressing changes routinely every 7 days or earlier if needed. The VAT consistently followed the bundled components, including use of chlorhexidine gluconate (CHG)-impregnated dressings on all patients unless an allergy was identified. In this case, a non-CHG transparent semipermeable membrane dressing was used. There were 884 patients with 14 211 CVAD days in the preimplementation period and 1136 patients with 14 225 CVAD days during the postimplementation period. The VAT saw 602 (53.0%) of the 1136 patients, performing at least 1 dressing change in 98% of the patients (n = 589). The combined CLABSI rate for the 2 units decreased from 2.53 per 1000 CVAD days preintervention to 1.62 per 1000 CVAD days postintervention. The estimated incidence rate ratio (IRR) for the intervention was 0.639, a 36.1% reduction in monthly CLABSI rates during the postimplementation period.


Subject(s)
Bandages , Catheter-Related Infections , Catheterization, Central Venous , Chlorhexidine , Humans , Catheter-Related Infections/prevention & control , Chlorhexidine/therapeutic use , Chlorhexidine/administration & dosage , Chlorhexidine/analogs & derivatives , Catheterization, Central Venous/adverse effects , Quality Improvement , Vascular Access Devices , Infection Control/methods , Hospitals, University
2.
Infect Control Hosp Epidemiol ; 45(3): 384-386, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37800346

ABSTRACT

We implemented 2 interventions to improve utilization and contamination at our institution: kits to improve appropriate sample collection and an electronic order alert displaying appropriate indications of fungal blood cultures. An electronic order alert when ordering fungal blood cultures was associated with decreased utilization without decrease in positivity rate.


Subject(s)
Blood Culture , Records , Humans
3.
Infect Prev Pract ; 5(1): 100268, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36785770

ABSTRACT

Prevention of hazardous drug exposure is essential in averting unnecessary health risks to health care workers (HCW). To address the risk to HCWs when handling hazardous drugs, engineering controls can be utilized to reduce the exposure. A closed system transfer device (CSTD) was introduced for hazardous drugs administration in 6 oncology wards; this new CSTD was associated with a significant increase in CLABSI rates.

SELECTION OF CITATIONS
SEARCH DETAIL
...