Clin Biochem ; 39(9): 893-7, 2006 Sep.
Article in English | MEDLINE | ID: mdl-16624273

ABSTRACT

OBJECTIVES: To evaluate the usefulness of Phe loading test in patients for the diagnosis of guanosine triphosphate cyclohydrolase 1 deficiency (GTPCH). DESIGN AND METHODS: We studied one family composed of 13 members harbouring the Q89X mutation in the GTPCH gene, a non-related pediatric patient with GTPCH deficiency and 8 pediatric controls. 100 mg/kg of L-phenylalanine was orally administered, and blood spot samples were taken at baselines 1, 2, 4 and 6 h post-load. RESULTS: Two out of 7 pediatric patients showed a phenylalanine/tyrosine ratio higher than the previously reported cut-off value of 5.25 at 4 h, while 6 of the 7 adult patients showed a higher value. The only adult patient with a phenylalanine/tyrosine ratio below 5.25 at 4 h was asymptomatic. CONCLUSIONS: A cut-off value of 5.25 seems reliable for interpreting Phe loading test in adult patients with GTPCH deficiency, although a lower value should be established for pediatric patients.


Subject(s)
Amino Acid Metabolism, Inborn Errors/diagnosis , GTP Cyclohydrolase/deficiency , Phenylalanine/administration & dosage , Administration, Oral , Adult , Child , Child, Preschool , Female , Humans , Infant , Male , Middle Aged , Time Factors