Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Radiother Oncol ; 128(2): 209-213, 2018 08.
Article in English | MEDLINE | ID: mdl-29859753

ABSTRACT

BACKGROUND AND PURPOSE: The purpose of this study was to investigate whether treatment information from medical records can be used to estimate radiation doses to heart and lungs retrospectively in pediatric patients receiving spinal irradiation with conventional posterior fields. MATERIAL AND METHODS: An algorithm for retrospective dosimetry in children treated with spinal irradiation was developed in a cohort of 21 pediatric patients with available CT-scans and treatment plans. We developed a multivariable linear regression model with explanatory variables identifiable in case note review for retrospective estimation of minimum, maximum, mean and V10%-V80% doses to the heart and lungs. Doses were estimated for both linear accelerator (Linac) and 60Co radiation therapy modalities. RESULTS: Age and spinal field width were identified as statistically significant predictors of heart and lung doses in multivariable analyses (p < 0.01 in all models). Models showed excellent predictive performance with R2 = 0.70 for mean heart dose and 0.79 for mean lung dose, for Linac plans. In leave-one-out cross-validation analysis the average difference between predicted and actual mean heart dose was 6.7% and 7.6% of the prescription dose for Linac and 60Co plans, respectively, and 5.2% and 4.9% for mean lung dose. Due to the small sample size and large inter-patient variation in heart and lung dose, prospective studies validating these findings are highly warranted. CONCLUSIONS: The models presented here provide retrospective estimates of heart and lung doses for historical cohorts of pediatric patients, thus facilitating studies of long-term adverse effects of radiation.


Subject(s)
Cerebellar Neoplasms/radiotherapy , Craniospinal Irradiation/adverse effects , Heart/radiation effects , Lung/radiation effects , Medulloblastoma/radiotherapy , Adolescent , Algorithms , Child , Child, Preschool , Female , Humans , Infant , Infant, Newborn , Male , Prospective Studies , Radiometry , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Retrospective Studies , Tomography, X-Ray Computed , Young Adult
2.
Acta Oncol ; 53(8): 1005-11, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24937551

ABSTRACT

BACKGROUND: Flattening filter-free (FFF) beams are an emerging technology that has not yet been widely implemented as standard practice in radiotherapy centers. To facilitate the clinical implementation of FFF, we attempted to elucidate the difference in plan quality and treatment delivery time compared to flattening filter beams (i.e. standard, STD) for several patient groups. We hypothesize that the treatment plan quality is comparable while the treatment delivery time of volumetric modulated arc therapy (VMAT) is considerably shorter using FFF beams, especially for stereotactic treatments. METHODS: A total of 120 patients treated for head and neck (H&N) tumors, high-grade glioma, prostate cancer, early stage lung cancer and intra-cranial metastatic disease (both single and multiple metastases) were included in the study. For each cohort, 20 consecutive patients were selected. The plans were generated using STD- and FFF-VMAT for both 6 MV and 10 MV, and were compared with respect to plan quality, monitor units and delivery time using Wilcoxon signed rank tests. RESULTS: For H&N and high-grade gliomas, there was a significant difference in homogeneity index in favor for STD-VMAT (p < 0.001). For the stereotactic sites there were no differences in plan conformity. Stereotactic FFF-VMAT plans required significantly shorter delivery time compared to STD-VMAT plans (p < 0.001) for higher dose per fraction, on average 54.5% for 6 MV and 71.4% for 10 MV. FFF-VMAT generally required a higher number of MU/Gy (p < 0.001), on average 7.0% for 6 MV and 8.4% for 10 MV. CONCLUSION: It was generally possible to produce FFF-VMAT plans with the same target dose coverage and doses to organs at risk as STD-VMAT plans. Target dose homogeneity tended to be somewhat inferior for FFF-VMAT for the larger targets investigated. For stereotactic radiotherapy, FFF-VMAT resulted in a considerable time gain while maintaining similar plan quality compared to STD beams.


Subject(s)
Brain Neoplasms/radiotherapy , Glioma/radiotherapy , Head and Neck Neoplasms/radiotherapy , Lung Neoplasms/radiotherapy , Prostatic Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Adult , Aged , Aged, 80 and over , Brain Neoplasms/secondary , Female , Filtration/instrumentation , Humans , Male , Middle Aged , Organs at Risk , Oropharyngeal Neoplasms/radiotherapy , Radiotherapy, Intensity-Modulated/instrumentation , Statistics, Nonparametric , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...