Hell J Nucl Med ; 18(2): 114-21, 2015.
Article in English | MEDLINE | ID: mdl-26187210

ABSTRACT

OBJECTIVE: Previous studies indicate that the quality of single photon emission tomography/computed tomography (SPET/CT) myocardial perfusion imaging (MPI) is degraded by even mild transmission-emission misregistrations. The purpose of the current study was to investigate the impact of SPET/CT misalignment on the interpretation of MPI and examine the value of a commercial software application for registration correction. SUBJECTS AND METHODS: A total of 255 technetium-99m ((99m)Tc)-tetrofosmin stress/rest MPI examinations in 150 patients were reviewed for SPET/CT misalignment. After registration correction by the software, images were reassessed for interpretation differences from the misregistered study. The diagnostic benefit of reregistration was determined by taking into account the non-attenuation compensated image pattern, combined stress-rest evaluation, gated-SPET data and patient's history. In a phantom experiment and in 3 representative clinical cases, SPET/CT misalignment was purposely created by the software by sequential slice shifts and its effect was evaluated quantitatively. RESULTS: Misregistration ≥1 pixel in at least one direction was observed in 24% of studies. Interpretation of MPI changed after registration correction in 11% of cases with misalignment <1 pixel, in 18% with 1-2 and in 73% with ≥2 pixels. The diagnostic information seemed to improve after registration correction in 58% of studies irrespective of the degree of misregistration. Software-simulated misregistration had dissimilar effects in the phantom and the 3 selected clinical cases. CONCLUSIONS: The impact of SPET/CT misregistration on MPI interpretation although influenced by the degree and direction of slice misplacement, it is also case-specific and hardly predictable. Registration restoration by the software seems worthwhile regardless of misregistration magnitude.


Subject(s)
Artifacts , Coronary Artery Disease/diagnosis , Myocardial Perfusion Imaging/methods , Subtraction Technique , Tomography, Emission-Computed, Single-Photon/methods , Tomography, X-Ray Computed/methods , Female , Humans , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Male , Middle Aged , Multimodal Imaging/methods , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...