Article in English | MEDLINE | ID: mdl-36070744

ABSTRACT

In respect of radiation dosimetry, several applications require dose distribution verification rather than absolute dosimetry. Most protocols use radiological and radiochromic films and ionization chambers or diode arrays for dose mapping. The films are disposable which causes the precision of the results dependent on film production variability. The measurements with arrays of ionization chambers or diodes mainly lack spatial resolution. This review aims to provide an overview of the use of optically stimulated luminescence detectors (OSLDs) for one-dimensional (1D) and two-dimensional (2D) dose mapping in different applications. It reviews the ideas, OSL materials, and applications related to the assessment of dose distribution using OSLDs in the form of film or ceramic plate (BeO). Additionally, it reviews research published in the international scientific literature from 1998 to 2021. As an outcome, a table containing the main characteristics of each relevant paper is shown. The results section was divided by the type of OSL material, and we briefly described the principal findings and the significant developments of each mentioned study such as film production and OSL reader assembly. The purpose of this study was to present an overview of the main findings of several research groups on the use of OSLD in the form of film or plate for 1D and 2D dose mapping. Finally, the potential future development of dose mapping using OSLD films was outlined.


Subject(s)
Optically Stimulated Luminescence Dosimetry , Luminescence , Luminescent Measurements , Optically Stimulated Luminescence Dosimetry/methods , Radiation Dosage , Radiometry
2.
Med Phys ; 37(7): 3560-8, 2010 Jul.
Article in English | MEDLINE | ID: mdl-20831063

ABSTRACT

PURPOSE: The extensive use of multislice computed tomography (MSCT) and the associated increase in patient dose calls for an accurate dose evaluation technique. Optically stimulated luminescence (OSL) dosimetry provides a potential solution to the arising concerns over patient dose. This study was intended to evaluate the feasibility and accuracy of OSL dosimeter systems in the diagnostic CT x-ray beam energy range. METHODS: MSCT dose profiles were measured by irradiating OSL strips placed inside the extended PMMA head and body phantoms at different scan conditions by varying kVp settings (100, 120, and 140 kVp) and collimated beam widths (5, 10, 20, and 40 mm). All scans in this study were performed using a GE Lightspeed VCT scanner in axial mode. The exposed strips were then read out using a custom-made OSL strip reader and corrected with field-specific conversion factors. Based on the corrected OSL dose profile, the CTDI(450-OSL) and CTDI(l00-OSL) were evaluated. CTDI(100-IC) was also obtained using a 100 mm long pencil ionization chamber for accuracy verification. CTDI(100-efficiency) can be further evaluated by calculating the ratio of CTDI(100-OSL) and CTDI(450-OSL), which was compared to results from previous studies as well. RESULTS: The OSL detectors were found to have good sensitivity and dose response over a wide range of diagnostic CT x-ray beam energy viz. the primary beam and the scatter tail section of the dose profile. The differences between CTDI100 values obtained using the OSL strips and those obtained with 100 mm long pencil ionization chamber were < +/- 5% for all scan conditions, indicating good accuracy of the OSL system. It was also found that the CTDI(100-efficiency) did not significantly change as the beam width increased and tube voltage changed. The average CTDI(100-efficiency) at the center of the head and body phantoms were 72.6% and 56.2%, respectively. The corresponding values for the periphery of the head and body phantoms were 85.0% and 81.7%. These results agreed very well with previous results from the literature using other detection techniques or Monte Carlo simulations. CONCLUSIONS: The LED-based OSL system can be an accurate alternative device for CT dose evaluations. CTDI100 measurement with the use of a 100 mm pencil ionization chamber substantially underestimates the CTDIinfinity value even with 5 mm collimated beam width. The established complete set of CTDI(100-efficiency) correction factors for various scan parameters allows for accurately estimating CTDIinfinity with the current use of pencil chamber and dose phantoms. Combined with the simple calibration, it gives this work great potential to be used not only in routine clinical quality assurance checks but also as a promising tool for patient organ dose assessment.


Subject(s)
Luminescent Measurements , Optical Phenomena , Radiometry/methods , Tomography, X-Ray Computed , Feasibility Studies , Humans , Monte Carlo Method , Phantoms, Imaging , Radiation Dosage , Radiometry/instrumentation , Reproducibility of Results
3.
Phys Med Biol ; 55(17): 4963-76, 2010 Sep 07.
Article in English | MEDLINE | ID: mdl-20693613

ABSTRACT

In this work we present a methodology and proof of concept to experimentally determine average linear energy transfer (LET) of therapeutic proton beams using the optically stimulated luminescence (OSL) of small Al(2)O(3):C detectors. Our methodology is based on the fact that the shape of the OSL decay curve of Al(2)O(3):C detectors depends on the LET of the radiation field. Thus, one can use the shape of the OSL decay curves to establish an LET calibration curve, which in turn permits measurements of LET. We performed irradiations at the M D Anderson Cancer Center Proton Therapy Center, Houston (PTCH), with passive scattering beams. We determined the average LET of the passive scattering beams using a validated Monte Carlo model of the PTCH passive scattering nozzle and correlated them with the shape of the OSL decay curve to obtain an LET calibration curve. Using this calibration curve and OSL measurements, we determined the averaged LET at various water-equivalent depths for therapeutic spread-out Bragg peaks and compared the results with averaged LETs determined using the Monte Carlo simulations. Agreement between measured and simulated fluence-averaged LET was within 24% for low energy spread-out Bragg peak (SOBP) fields and within 14% for high energy SOBP fields. Agreement between measured and simulated dose-averaged LET was within 12% for low energy SOBP fields and within 47% for high energy SOBP fields. The data presented in this work demonstrated the correlation between the OSL decay curve shapes and the average LET of the radiation fields, providing proof of concept of the feasibility of using OSL from Al(2)O(3):C detectors to measure average LET of therapeutic proton beams.


Subject(s)
Aluminum Oxide/chemistry , Carbon/chemistry , Linear Energy Transfer , Luminescent Measurements/instrumentation , Proton Therapy , Radiotherapy, High-Energy/instrumentation , Algorithms , Computer Simulation , Luminescent Measurements/methods , Monte Carlo Method , Radiotherapy, High-Energy/methods