Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Neurointervention ; 19(1): 6-13, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38224721

ABSTRACT

PURPOSE: Mechanical thrombectomy (MT) is the standard of care for acute ischemic stroke (AIS) due to large vessel occlusion (LVO). The choice of a transradial approach (TRA) for anterior circulation LVOs is still debatable; the use of a specific tricoaxial system could help mitigate numerous issues related to transradial MT. MATERIALS AND METHODS: From November 2022 to November 2023, 22 patients underwent TRA-MT for anterior circulation LVOs, both as first-line and rescue from transfemoral approach (TFA) failure, with the same triaxial setup consisting of a 7F introducer sheath, 7F guide catheter, and aspiration catheters ranging from 5.5F to 5F in relation to the occlusion site. Choice of thrombectomy technique was at operator discretion. Patients' demographic data, clinical presentation, treatment details, complications, rate of crossover to TFA, successful revascularization (modified thrombolysis in cerebral infarction [mTICI] score ≥2b), and good clinical outcome at 3 months (modified Rankin scale [mRS] 0-2) were reported. RESULTS: Of 20 patients selected, 10 (50%) had occlusion of M1 segment of middle cerebral artery (MCA), 6 (30%) of internal carotid artery (ICA) terminus, and 4 (20%) with M2 MCA occlusions; 12/20 (60%) were right-sided occlusions and 8/20 (40%) were left-sided. The mean National Institutes of Health Stroke Scale score was 9.25 at admission. Successful revascularization to mTICI 2b-3 was achieved in 18/20 patients (90%). Intracranial complications were reported in 2 (10%) patients. Rate of radial artery occlusion at 24 hours was 10,6%; no access-site haemorrhagic complications were reported. Symptomatic intracranial hemorrhage occurred in 2 (10%) patients. mRS score 0-2 at 3 months was 50%. CONCLUSION: The high technical effectiveness and good safety profile of this specific tricoaxial setup for TRA-MT in AIS, even for large proximal LVOs, could constitute a viable alternative to TFA-MT in selected cases.

2.
BMJ Case Rep ; 15(4)2022 Apr 19.
Article in English | MEDLINE | ID: mdl-35440434

ABSTRACT

Fetal-type posterior communicating artery (FPCom) aneurysms are associated with higher rates of recurrence after endovascular treatment than aneurysms at other locations. We report the case of a patient with a subarachnoid haemorrhage and ruptured right-sided FPCom aneurysm. The patient underwent acute endovascular treatment with application of a novel combined approach-partial coiling to protect the dome and occlusion of the neck with a new flow-disrupter, endosaccular device, Contour (Cerus Endovascular)-as a stable, single-step treatment to prevent rebleeding in the acute stage and long-term potential recurrences.


Subject(s)
Aneurysm, Ruptured , Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Subarachnoid Hemorrhage , Aneurysm, Ruptured/diagnostic imaging , Aneurysm, Ruptured/surgery , Cerebral Angiography , Humans , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/surgery , Retrospective Studies , Subarachnoid Hemorrhage/diagnostic imaging , Subarachnoid Hemorrhage/surgery , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...