Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 94
Filter
1.
Article in English | MEDLINE | ID: mdl-38965895

ABSTRACT

The bicuspid aortic valve (BAV) is the most common congenital heart defect among adults, often leading to severe valve dysfunction and aortic complications. Despite its clinical significance, uncertainties persist regarding the impact of sports participation on the natural course of BAV disease. The SPREAD (Sport PRactice and its Effects on Bicuspid Aortic valve Disease) study is a multicenter and multinational project designed to investigate this relationship. This paper outlines the study's design, and objectives. The study is divided into two phases; phase one involves a cross-sectional analysis comparing aortic dimensions and valve function among competitive athletes with BAV, athletes with tricuspid aortic valves (TAV), and sedentary individuals with BAV. The second phase is a prospective, longitudinal follow-up aiming to evaluate the impact of regular sports training on disease progression. The SPREAD study seeks to provide evidence-based insights into the effects of sports participation on BAV disease progression, guiding clinical decision-making regarding sports eligibility and risk stratification for individuals with BAV.

2.
Radiol Cardiothorac Imaging ; 6(3): e230247, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38900026

ABSTRACT

Purpose To use unsupervised machine learning to identify phenotypic clusters with increased risk of arrhythmic mitral valve prolapse (MVP). Materials and Methods This retrospective study included patients with MVP without hemodynamically significant mitral regurgitation or left ventricular (LV) dysfunction undergoing late gadolinium enhancement (LGE) cardiac MRI between October 2007 and June 2020 in 15 European tertiary centers. The study end point was a composite of sustained ventricular tachycardia, (aborted) sudden cardiac death, or unexplained syncope. Unsupervised data-driven hierarchical k-mean algorithm was utilized to identify phenotypic clusters. The association between clusters and the study end point was assessed by Cox proportional hazards model. Results A total of 474 patients (mean age, 47 years ± 16 [SD]; 244 female, 230 male) with two phenotypic clusters were identified. Patients in cluster 2 (199 of 474, 42%) had more severe mitral valve degeneration (ie, bileaflet MVP and leaflet displacement), left and right heart chamber remodeling, and myocardial fibrosis as assessed with LGE cardiac MRI than those in cluster 1. Demographic and clinical features (ie, symptoms, arrhythmias at Holter monitoring) had negligible contribution in differentiating the two clusters. Compared with cluster 1, the risk of developing the study end point over a median follow-up of 39 months was significantly higher in cluster 2 patients (hazard ratio: 3.79 [95% CI: 1.19, 12.12], P = .02) after adjustment for LGE extent. Conclusion Among patients with MVP without significant mitral regurgitation or LV dysfunction, unsupervised machine learning enabled the identification of two phenotypic clusters with distinct arrhythmic outcomes based primarily on cardiac MRI features. These results encourage the use of in-depth imaging-based phenotyping for implementing arrhythmic risk prediction in MVP. Keywords: MR Imaging, Cardiac, Cardiac MRI, Mitral Valve Prolapse, Cluster Analysis, Ventricular Arrhythmia, Sudden Cardiac Death, Unsupervised Machine Learning Supplemental material is available for this article. © RSNA, 2024.


Subject(s)
Mitral Valve Prolapse , Phenotype , Unsupervised Machine Learning , Humans , Mitral Valve Prolapse/diagnostic imaging , Female , Male , Middle Aged , Retrospective Studies , Registries , Magnetic Resonance Imaging, Cine/methods , Arrhythmias, Cardiac/diagnostic imaging , Arrhythmias, Cardiac/physiopathology , Adult , Magnetic Resonance Imaging
3.
Circulation ; 149(25): 1938-1948, 2024 06 18.
Article in English | MEDLINE | ID: mdl-38804148

ABSTRACT

BACKGROUND: Ascending aorta dilation and aortic valve degeneration are common complications in patients with bicuspid aortic valve. Several retrospective studies have suggested the benefit of statins in reducing these complications. This study aimed to determine whether atorvastatin treatment is effective in reducing the growth of aortic diameters in bicuspid aortic valve and if it slows the progression of valve calcification. METHODS: In a randomized clinical trial, 220 patients with bicuspid aortic valve (43 women; 46±13 years of age) were included and treated with either 20 mg of atorvastatin per day or placebo for 3 years. Inclusion criteria were ≥18 years of age, nonsevere valvular dysfunction, nonsevere valve calcification, and ascending aorta diameter ≤50 mm. Computed tomography and echocardiography studies were performed at baseline and after 3 years of treatment. RESULTS: During follow-up, 28 patients (12.7%) discontinued medical treatment (15 on atorvastatin and 13 taking placebo). Thus, 192 patients completed the 36 months of treatment. Low-density lipoprotein cholesterol levels decreased significantly in the atorvastatin group (median [interquartile range], -30 mg/dL [-51.65 to -1.75 mg/dL] versus 6 mg/dL [-4, 22.5 mg/dL]; P<0.001). The maximum ascending aorta diameter increased with no differences between groups: 0.65 mm (95% CI, 0.45-0.85) in the atorvastatin group and 0.74 mm (95% CI, 0.45-1.04) in the placebo group (P=0.613). Similarly, no significant differences were found for the progression of the aortic valve calcium score (P=0.167) or valvular dysfunction. CONCLUSIONS: Among patients with bicuspid aortic valve without severe valvular dysfunction, atorvastatin treatment was not effective in reducing the progression of ascending aorta dilation and aortic valve calcification during 3 years of treatment despite a significant reduction in low-density lipoprotein cholesterol levels. REGISTRATION: URL: https://www.clinicaltrialsregister.eu; Unique identifier: 2015-001808-57. URL: https://www.clinicaltrials.gov; Unique identifier: NCT02679261.


Subject(s)
Aortic Valve , Atorvastatin , Bicuspid Aortic Valve Disease , Calcinosis , Disease Progression , Heart Valve Diseases , Hydroxymethylglutaryl-CoA Reductase Inhibitors , Humans , Atorvastatin/therapeutic use , Female , Male , Middle Aged , Aortic Valve/diagnostic imaging , Aortic Valve/pathology , Aortic Valve/abnormalities , Aortic Valve/drug effects , Calcinosis/drug therapy , Calcinosis/diagnostic imaging , Calcinosis/pathology , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/drug therapy , Heart Valve Diseases/drug therapy , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/pathology , Adult , Hydroxymethylglutaryl-CoA Reductase Inhibitors/therapeutic use , Dilatation, Pathologic/drug therapy , Follow-Up Studies , Double-Blind Method , Treatment Outcome , Aorta/diagnostic imaging , Aorta/pathology , Aorta/drug effects , Aortic Valve Disease/drug therapy , Aortic Valve Stenosis
5.
Biomedicines ; 12(2)2024 Feb 06.
Article in English | MEDLINE | ID: mdl-38397982

ABSTRACT

INTRODUCTION AND PURPOSE: Bicuspid aortic valve (BAV) disease is associated with faster aortic valve degeneration and a high incidence of aortic stenosis (AS). In this study, we aimed to identify differences in the pathophysiology of AS between BAV and tricuspid aortic valve (TAV) patients in a multiomics study integrating metabolomics and transcriptomics as well as clinical data. METHODS: Eighteen patients underwent aortic valve replacement due to severe aortic stenosis: 8 of them had a TAV, while 10 of them had a BAV. RNA sequencing (RNA-seq) and proton nuclear magnetic resonance spectroscopy (1H-NMR) were performed on these tissue samples to obtain the RNA profile and lipid and low-molecular-weight metabolites. These results combined with clinical data were posteriorly compared, and a multiomic profile specific to AS in BAV disease was obtained. RESULTS: H-NMR results showed that BAV patients with AS had different metabolic profiles than TAV patients. RNA-seq also showed differential RNA expression between the groups. Functional analysis helped connect this RNA pattern to mitochondrial dysfunction. Integration of RNA-seq, 1H-NMR and clinical data helped create a multiomic profile that suggested that mitochondrial dysfunction and oxidative stress are key players in the pathophysiology of AS in BAV disease. CONCLUSIONS: The pathophysiology of AS in BAV disease differs from patients with a TAV and has a specific RNA and metabolic profile. This profile was associated with mitochondrial dysfunction and increased oxidative stress.

6.
J Cardiovasc Magn Reson ; 26(1): 100992, 2024.
Article in English | MEDLINE | ID: mdl-38211655

ABSTRACT

BACKGROUND: The measurement of aortic dimensions and their evolution are key in the management of patients with aortic diseases. Manual assessment, the current guideline-recommended method and clinical standard, is subjective, poorly reproducible, and time-consuming, limiting the capacity to track aortic growth in everyday practice. Aortic geometry mapping (AGM) via image registration of serial computed tomography angiograms outperforms manual assessment, providing accurate and reproducible 3D maps of aortic diameter and growth rate. This observational study aimed to evaluate the accuracy and reproducibility of AGM on non-gated contrast-enhanced (CE-) and cardiac- and respiratory-gated (GN-) magnetic resonance angiographies (MRA). METHODS: Patients with thoracic aortic disease followed with serial CE-MRA (n = 30) or GN-MRA (n = 15) acquired at least 1 year apart were retrospectively and consecutively identified. Two independent observers measured aortic diameters and growth rates (GR) manually at several thoracic aorta reference levels and with AGM. Agreement between manual and AGM measurements and their inter-observer reproducibility were compared. Reproducibility for aortic diameter and GR maps assessed with AGM was obtained. RESULTS: Mean follow-up was 3.8 ± 2.3 years for CE- and 2.7 ± 1.6 years for GN-MRA. AGM was feasible in the 93% of CE-MRA pairs and in the 100% of GN-MRA pairs. Manual and AGM diameters showed excellent agreement and inter-observer reproducibility (ICC>0.9) at all anatomical levels. Agreement between manual and AGM GR was more limited, both in the aortic root by GN-MRA (ICC=0.47) and in the thoracic aorta, where higher accuracy was obtained with GN- than with CE-MRA (ICC=0.55 vs 0.43). The inter-observer reproducibility of GR by AGM was superior compared to manual assessment, both with CE- (thoracic: ICC= 0.91 vs 0.51) and GN-MRA (root: ICC=0.84 vs 0.52; thoracic: ICC=0.93 vs 0.60). AGM-based 3D aortic size and growth maps were highly reproducible (median ICC >0.9 for diameters and >0.80 for GR). CONCLUSION: Mapping aortic diameter and growth on MRA via 3D image registration is feasible, accurate and outperforms the current manual clinical standard. This technique could broaden the possibilities of clinical and research evaluation of patients with aortic thoracic diseases.


Subject(s)
Aorta, Thoracic , Aortic Diseases , Contrast Media , Imaging, Three-Dimensional , Magnetic Resonance Angiography , Observer Variation , Predictive Value of Tests , Humans , Reproducibility of Results , Male , Female , Retrospective Studies , Middle Aged , Aorta, Thoracic/diagnostic imaging , Aged , Contrast Media/administration & dosage , Aortic Diseases/diagnostic imaging , Respiratory-Gated Imaging Techniques , Adult , Time Factors , Image Interpretation, Computer-Assisted , Cardiac-Gated Imaging Techniques
7.
Eur Radiol ; 34(8): 5190-5200, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38183450

ABSTRACT

OBJECTIVES: Partial thrombosis of the false lumen (FL) in patients with chronic aortic dissection (AD) of the descending aorta has been associated with poor outcomes. Meanwhile, the fluid dynamic and biomechanical characteristics associated with partial thrombosis remain to be elucidated. This retrospective, single-center study tested the association between FL fluid dynamics and biomechanics and the presence and extent of FL thrombus. METHODS: Patients with chronic non-thrombosed or partially thrombosed FLs in the descending aorta after an aortic dissection underwent computed tomography angiography, cardiovascular magnetic resonance (CMR) angiography, and a 4D flow CMR study. A comprehensive quantitative analysis was performed to test the association between FL thrombus presence and extent (percentage of FL with thrombus) and FL anatomy (diameter, entry tear location and size), fluid dynamics (inflow, rotational flow, wall shear stress, kinetic energy, and flow acceleration and stasis), and biomechanics (pulse wave velocity). RESULTS: Sixty-eight patients were included. In multivariate logistic regression FL kinetic energy (p = 0.038) discriminated the 33 patients with partial FL thrombosis from the 35 patients with no thrombosis. Similarly, in separated multivariate linear correlations kinetic energy (p = 0.006) and FL inflow (p = 0.002) were independently related to the extent of the thrombus. FL vortexes, flow acceleration and stasis, wall shear stress, and pulse wave velocity showed limited associations with thrombus presence and extent. CONCLUSION: In patients with chronic descending aorta dissection, false lumen kinetic energy is related to the presence and extent of false lumen thrombus. CLINICAL RELEVANCE STATEMENT: In patients with chronic aortic dissection of the descending aorta, false lumen hemodynamic parameters are closely linked with the presence and extent of false lumen thrombosis, and these non-invasive measures might be important in patient management. KEY POINTS: • Partial false lumen thrombosis has been associated with aortic growth in patients with chronic descending aortic dissection; therefore, the identification of prothrombotic flow conditions is desirable. • The presence of partial false lumen thrombosis as well as its extent was related with false lumen kinetic energy. • The assessment of false lumen hemodynamics may be important in the management of patients with chronic aortic dissection of the descending aorta.


Subject(s)
Aorta, Thoracic , Aortic Dissection , Hemodynamics , Thrombosis , Humans , Male , Female , Aortic Dissection/diagnostic imaging , Aortic Dissection/physiopathology , Aortic Dissection/complications , Middle Aged , Retrospective Studies , Thrombosis/diagnostic imaging , Thrombosis/physiopathology , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/physiopathology , Computed Tomography Angiography/methods , Chronic Disease , Aged , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/physiopathology , Aortic Aneurysm, Thoracic/complications , Magnetic Resonance Angiography/methods
8.
Can J Cardiol ; 2023 Nov 25.
Article in English | MEDLINE | ID: mdl-38013065

ABSTRACT

BACKGROUND: Percutaneous mitral paravalvular leak (PVL) closure techniques are an effective and safe alternative to surgical treatment, but data regarding long-term outcomes are scarce. We aim to describe the impact of successful percutaneous mitral PVL closure on long-term outcomes. METHODS: All consecutive patients in whom a first-attempt percutaneous mitral PVL closure was performed in a single tertiary centre between January 2010 and October 2021 were included. Clinical variables, procedural details, and procedural success were collected. Patients were classified based on procedural success, defined as no more than mild residual leak. All-cause mortality was the primary endpoint. Cardiovascular death and heart failure hospitalizations (HFHs) were key secondary endpoints. RESULTS: Ninety patients (median age 72.5 years [66.0-78.4]; median EuroSCORE-II 8.2 [5.3-12.46]) were included. Although reduction of at least 1 degree in PVL severity was achieved in 82 (91.1%), procedural success was achieved in 47 (52.2%). Chronic kidney disease, previous surgery for PVL, and the presence of multiple jets were independently associated with procedural failure. After a median follow-up of 3.2 (1.2-5.2) years, mortality rate was higher in the procedural failure group (27.3 per 100 patients-years) compared with the group with successful closure (8.2 per 100 patient-years). Procedural failure was associated with all-cause death (adjusted hazard ratio [aHR], 2.59; 95% confidence interval [CI], 1.41-4.78), cardiovascular death (aHR, 3.53; 95% CI, 1.67-7.49) and HFH (aHR, 3.27; 95% CI,1.72-6.20). CONCLUSIONS: A successful reduction in PVL to mild or absent is associated with improved rates of all-cause death, cardiovascular death, and HFHs.

9.
Article in English | MEDLINE | ID: mdl-37490995

ABSTRACT

BACKGROUND: Blunt traumatic thoracic aortic injuries (BTAIs) are associated with a high mortality rate. Thoracic endovascular aortic repair (TEVAR) is the most frequently used surgical strategy in patients with BTAI, as it offers good short- and middle-term results. Previous studies have reported an abnormally high prevalence of hypertension (HT) in these patients. This work aimed to describe the long-term prevalence of HT and provide a comprehensive evaluation of the biomechanical, clinical, and functional factors involved in HT development. METHODS: Twenty-six patients treated with TEVAR following BTAI with no history of HT at the time of trauma were enrolled. They were matched with 37 healthy volunteers based on age, sex, and body surface area and underwent a comprehensive follow-up study, including cardiovascular magnetic resonance, 24-hour ambulatory blood pressure monitoring, and assessment of carotid-femoral pulse wave velocity (cfPWV, a measure of aortic stiffness) and flow-mediated vasodilation. RESULTS: The mean patient age was 43.5 ± 12.9 years, and the majority were male (23 of 26; 88.5%). At a mean of 120.2 ± 69.7 months after intervention, 17 patients (65%) presented with HT, 14 (54%) had abnormal nighttime blood pressure dipping, and 6 (23%) high cfPWV. New-onset HT was related to a more proximal TEVAR landing zone and greater distal oversizing. Abnormal nighttime blood pressure was related to high cfPWV, which in turn was associated with TEVAR length and premature arterial aging. CONCLUSIONS: HT frequently occurs otherwise healthy subjects undergoing TEVAR implantation after BTAI. TEVAR stiffness and length, the proximal landing zone, and distal oversizing are potentially modifiable surgical characteristics related to abnormal blood pressure.

10.
J Am Coll Cardiol ; 82(5): 448-464, 2023 08 01.
Article in English | MEDLINE | ID: mdl-37495282

ABSTRACT

Bicuspid aortic valve is the most common congenital heart disease and exposes patients to an increased risk of aortic dilation and dissection. Aortic dilation is a slow, silent process, leading to a greater risk of aortic dissection. The prevention of adverse events together with optimization of the frequency of the required lifelong imaging surveillance are important for both clinicians and patients and motivated extensive research to shed light on the physiopathologic processes involved in bicuspid aortic valve aortopathy. Two main research hypotheses have been consolidated in the last decade: one supports a genetic basis for the increased prevalence of dilation, in particular for the aortic root, and the second supports the damaging impact on the aortic wall of altered flow dynamics associated with these structurally abnormal valves, particularly significant in the ascending aorta. Current opinion tends to rule out mutually excluding causative mechanisms, recognizing both as important and potentially clinically relevant.


Subject(s)
Aortic Diseases , Bicuspid Aortic Valve Disease , Heart Valve Diseases , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/abnormalities , Heart Valve Diseases/complications , Heart Valve Diseases/epidemiology , Dilatation , Aortic Diseases/complications
11.
Eur Heart J Cardiovasc Imaging ; 24(8): 1120-1128, 2023 07 24.
Article in English | MEDLINE | ID: mdl-37131301

ABSTRACT

AIMS: To assess the progression of the disease and evolution of the main echocardiographic variables for quantifying AS in patients with severe low-flow low-gradient (LFLG) AS compared to other severe AS subtypes. METHODS AND RESULTS: Longitudinal, observational, multicenter study including consecutive asymptomatic patients with severe AS (aortic valve area, AVA < 1.0 cm²) and normal left ventricle ejection fraction (LVEF ≥ 50%). Patients were classified according to baseline echocardiography into: HG (high gradient; mean gradient ≥ 40 mmHg), NFLG (normal-flow low-gradient; mean gradient < 40 mmHg, indexed systolic volume (SVi) > 35mL/m2), or LFLG (mean gradient < 40 mmHg, SVi ≤ 35 mL/m²). AS progression was analyzed by comparing patients' baseline measurements and their last follow-up measurements or those taken prior to aortic valve replacement (AVR). Of the 903 included patients, 401 (44.4%) were HG, 405 (44.9%) NFLG, and 97 (10.7%) LFLG. Progression of the mean gradient in a linear mixed regression model was greater in low-gradient groups: LFLG vs. HG (regression coefficient 0.124, P = 0.005) and NFLG vs. HG (regression coefficient 0.068, P = 0.018). No differences were observed between the LFLG and NFLG groups (regression coefficient 0.056, P = 0.195). However, AVA reduction was slower in the LFLG group compared to the NFLG (P < 0.001). During follow-up, in conservatively-managed patients, 19.1% (n = 9) of LFLG patients evolved to having NFLG AS and 44.7% (n = 21) to having HG AS. In patients undergoing AVR, 58.0% (n = 29) of LFLG baseline patients received AVR with a HG AS. CONCLUSION: LFLG AS shows an intermediate AVA and gradient progression compared to NFLG and HG AS. The majority of patients initially classified as having LFLG AS changed over time to having other severe forms of AS, and most of them received AVR with a HG AS.


Subject(s)
Aortic Valve Stenosis , Humans , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Echocardiography , Aortic Valve/diagnostic imaging , Ventricular Function, Left , Stroke Volume , Severity of Illness Index , Treatment Outcome , Retrospective Studies
12.
Heart ; 109(15): 1153-1158, 2023 07 12.
Article in English | MEDLINE | ID: mdl-37147129

ABSTRACT

OBJECTIVES: To describe the aortic-related risks associated with pregnancy in women with bicuspid aortic valve (BAV) and to evaluate changes in aortic diameter in pregnancy. METHODS: Prospective observational study of patients with BAV from a single-site registry of pregnant women with structural heart disease between 2013 and 2020. Cardiac, obstetric and neonatal outcomes were studied. An assessment of aortic dimensions was performed during pregnancy by two-dimensional echocardiography. Aortic diameters were measured at the annulus, root, sinotubular junction and maximum ascending aorta diameter, and the largest diameter was used. Measurements of the aorta were made using the end-diastolic leading edge-to-leading edge convention. RESULTS: Forty-three women (32.9 years, IQR 29.6-35.3) with BAV were included: 9 (20.9%) had repaired aortic coarctation; 23 (53.5%) had moderate or severe aortic valve disease; 5 (11.6%) had a bioprosthetic aortic valve; and 2 (4.7%) had a mechanical prosthetic aortic valve. Twenty (47.0%) were nulliparous. The mean aortic diameter in the first trimester was 38.5 (SD 4.9) mm, and that in the third trimester was 38.4 (SD 4.8) mm. Forty (93.0%) women had an aortic diameter of <45 mm; 3 (7.0%) had 45-50 mm; and none had >50 mm. Three women (6.9%) with BAV presented cardiovascular complications during pregnancy or the postpartum period (two prosthetic thrombosis and one heart failure). No aortic complications were reported. There was a small but significant increase in aortic diameter during pregnancy (third trimester vs first trimester, 0.52 (SD 1.08) mm; p=0.03). Obstetric complications appeared in seven (16.3%) of pregnancies, and there were no maternal deaths. Vaginal non-instrumental delivery was performed in 21 (51.2%) out of 41 cases. There were no neonatal deaths, and the mean newborn weight was 3130 g (95% CI 2652 to 3380). CONCLUSIONS: Pregnancy in BAV women had a low rate of cardiac complications with no aortic complications observed in a small study group. Neither aortic dissection nor need for aortic surgery was reported. A low but significant aortic growth was observed during pregnancy. Although requiring follow-up, the risk of aortic complications in pregnant women with BAV and aortic diameters of <45 mm at baseline is low.


Subject(s)
Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Heart Valve Diseases , Pregnancy , Infant, Newborn , Humans , Female , Male , Heart Valve Diseases/diagnosis , Heart Valve Diseases/diagnostic imaging , Aorta/diagnostic imaging , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Retrospective Studies
13.
Cancer Discov ; 13(5): 1144-1163, 2023 05 04.
Article in English | MEDLINE | ID: mdl-37071673

ABSTRACT

Cancers often overexpress multiple clinically relevant oncogenes, but it is not known if combinations of oncogenes in cellular subpopulations within a cancer influence clinical outcomes. Using quantitative multispectral imaging of the prognostically relevant oncogenes MYC, BCL2, and BCL6 in diffuse large B-cell lymphoma (DLBCL), we show that the percentage of cells with a unique combination MYC+BCL2+BCL6- (M+2+6-) consistently predicts survival across four independent cohorts (n = 449), an effect not observed with other combinations including M+2+6+. We show that the M+2+6- percentage can be mathematically derived from quantitative measurements of the individual oncogenes and correlates with survival in IHC (n = 316) and gene expression (n = 2,521) datasets. Comparative bulk/single-cell transcriptomic analyses of DLBCL samples and MYC/BCL2/BCL6-transformed primary B cells identify molecular features, including cyclin D2 and PI3K/AKT as candidate regulators of M+2+6- unfavorable biology. Similar analyses evaluating oncogenic combinations at single-cell resolution in other cancers may facilitate an understanding of cancer evolution and therapy resistance. SIGNIFICANCE: Using single-cell-resolved multiplexed imaging, we show that selected subpopulations of cells expressing specific combinations of oncogenes influence clinical outcomes in lymphoma. We describe a probabilistic metric for the estimation of cellular oncogenic coexpression from IHC or bulk transcriptomes, with possible implications for prognostication and therapeutic target discovery in cancer. This article is highlighted in the In This Issue feature, p. 1027.


Subject(s)
Lymphoma, Large B-Cell, Diffuse , Phosphatidylinositol 3-Kinases , Humans , Phosphatidylinositol 3-Kinases/genetics , Proto-Oncogene Proteins c-bcl-6/genetics , Prognosis , Proto-Oncogene Proteins c-bcl-2/genetics , Proto-Oncogene Proteins c-bcl-2/metabolism , Proto-Oncogene Proteins c-myc/genetics , Proto-Oncogene Proteins c-myc/metabolism , Oncogenes , Lymphoma, Large B-Cell, Diffuse/pathology
14.
J Am Soc Echocardiogr ; 36(4): 402-410, 2023 04.
Article in English | MEDLINE | ID: mdl-36332801

ABSTRACT

BACKGROUND: Significant (moderate or greater) mitral regurgitation (MR) could augment the hemodynamic effects of aortic valvular disease in patients with bicuspid aortic valve (BAV), imposing a greater hemodynamic burden on the left ventricle and atrium, possibly culminating in a faster onset of left ventricular dilation and/or symptoms. The aim of this study was to determine the prevalence and prognostic implications of significant MR in patients with BAV. METHODS: In this large, multicenter, international registry, a total of 2,932 patients (mean age, 48 ± 18 years; 71% men) with BAV were identified. All patients were evaluated for the presence of significant primary or secondary MR by transthoracic echocardiography and were followed up for the end points of all-cause mortality and event-free survival. RESULTS: Overall, 147 patients (5.0%) had significant primary (1.5%) or secondary (3.5%) MR. Significant MR was associated with all-cause mortality (hazard ratio [HR], 2.80; 95% CI, 1.91-4.11; P < .001) and reduced event-free survival (HR, 1.97; 95% CI, 1.58-2.46; P < .001) on univariable analysis. MR was not associated with all-cause mortality (adjusted HR, 1.33; 95% CI, 0.85-2.07; P = .21) or event-free survival (adjusted HR, 1.10; 95% CI, 0.85-1.42; P = .49) after multivariable adjustment. However, sensitivity analyses demonstrated that significant MR not due to aortic valve disease retained an independent association with mortality (adjusted HR, 1.81; 95% CI, 1.04-3.15; P = .037). Subgroup analyses demonstrated an independent association between significant MR and all-cause mortality for individuals with significant aortic regurgitation (HR, 2.037; 95% CI, 1.025-4.049; P = .042), although this association was not observed for subgroups with significant aortic stenosis or without significant aortic valve dysfunction. CONCLUSIONS: Significant MR is uncommon in patients with BAV. Following adjustment for important confounding variables, significant MR was not associated with adverse prognosis in this large study of patients with BAV, except for the patient subgroup with moderate to severe aortic regurgitation. In addition, significant MR not due to aortic valve disease demonstrated an independent association with all-cause mortality.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Mitral Valve Insufficiency , Male , Humans , Adult , Middle Aged , Aged , Female , Bicuspid Aortic Valve Disease/complications , Prognosis , Prevalence , Retrospective Studies , Aortic Valve , Aortic Valve Stenosis/diagnosis
15.
JACC Adv ; 2(8): 100626, 2023 Oct.
Article in English | MEDLINE | ID: mdl-38938356

ABSTRACT

Background: Clinical outcomes of bicuspid aortic valve (BAV) patients with ascending aortic diameters ≥50 mm who are under surveillance are poorly defined. Objectives: The purpose of this study was to assess clinical outcomes in BAV patients with ascending aorta ≥50 mm. Methods: Multicenter retrospective cohort study of BAV adults with ascending aorta diameters ≥50 mm by transthoracic echocardiography (TTE). Patients were categorized into 50 to 54 mm and ≥55 mm groups. Clinical outcomes were aortic dissection (AoD), aorta surgery, surgical mortality, and all-cause death. Results: Of 875 consecutive BAV patients (age 60 ± 13 years, 86% men, aortic diameter 51 mm [interquartile range (IQR): 50-53 mm]), 328 (37%) underwent early surgery ≤3 months from index TTE. Of the remaining 547 patients under surveillance, 496 had diameters 50 to 54 mm and 51 had diameters ≥55 mm and were collectively followed for 7.51 (IQR: 3.98-12.20) years. Of 496 patients with diameters 50 to 54 mm under surveillance, 266 (54%) underwent surgery 2.0 (IQR: 0.77-4.16) years from index TTE. AoD occurred in 9/496 (1.8%) patients for an incidence of 0.4 cases per 100 person-years, surgical mortality was 5/266 (1.9%); and ≥moderate aortic stenosis (but not aorta size) was associated with all-cause death, hazard ratio: 2.05 (95% CI: 1.32-3.20), P = 0.001. Conversely, in 547 total patients under surveillance (including 50-54 mm and ≥55 mm), both aorta size and ≥moderate aortic stenosis were associated with all-cause death (both P ≤ 0.027). AoD rate in patients ≥55 mm under surveillance was 5.9%. Conclusions: In BAV patients with ascending aorta 50 to 54 mm under surveillance, AoD incidence is low and the overall rates of AoD and surgical mortality are similar, suggesting clinical equivalence between surgical and surveillance strategies. Conversely, patients with aortas ≥55 mm should undergo surgery. Aortic stenosis is associated with all-cause death in these patients.

17.
J Am Coll Cardiol ; 80(11): 1071-1084, 2022 09 13.
Article in English | MEDLINE | ID: mdl-36075677

ABSTRACT

BACKGROUND: The prognostic impact of left ventricular ejection fraction (LVEF) in patients with bicuspid aortic valve (BAV) disease has not been previously studied. OBJECTIVES: The purpose of this study was to determine the prognostic impact of LVEF in BAV patients according to the type of aortic valve dysfunction. METHODS: We retrospectively analyzed the data collected in 2,672 patients included in an international registry of patients with BAV. Patients were classified according to the type of aortic valve dysfunction: isolated aortic stenosis (AS) (n = 749), isolated aortic regurgitation (AR) (n = 554), mixed aortic valve disease (MAVD) (n = 190), or no significant aortic valve dysfunction (n = 1,179; excluded from this analysis). The study population was divided according to LVEF strata to investigate its impact on clinical outcomes. RESULTS: The risk of all-cause mortality and the composite endpoint of aortic valve replacement or repair (AVR) and all-cause mortality increased when LVEF was <60% in the whole cohort as well as in the AS and AR groups, and when LVEF was <55% in MAVD group. In multivariable analysis, LVEF strata were significantly associated with increased rate of mortality (LVEF 50%-59%: HR: 1.83 [95% CI: 1.09-3.07]; P = 0.022; LVEF 30%-49%: HR: 1.97 [95% CI: 1.13-3.41]; P = 0.016; LVEF <30%: HR: 4.20 [95% CI: 2.01-8.75]; P < 0.001; vs LVEF 60%-70%, reference group). CONCLUSIONS: In BAV patients, the risk of adverse clinical outcomes increases significantly when the LVEF is <60%. These findings suggest that LVEF cutoff values proposed in the guidelines to indicate intervention should be raised from 50% to 60% in AS or AR and 55% in MAVD.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Heart Valve Prosthesis Implantation , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Heart Valve Prosthesis Implantation/adverse effects , Humans , Retrospective Studies , Risk Factors , Stroke Volume , Treatment Outcome , Ventricular Function, Left
18.
Front Cardiovasc Med ; 9: 852954, 2022.
Article in English | MEDLINE | ID: mdl-35433871

ABSTRACT

Objectives: To determine the risk of mortality and need for aortic valve replacement (AVR) in patients with low-flow low-gradient (LFLG) aortic stenosis (AS). Methods: A longitudinal multicentre study including consecutive patients with severe AS (aortic valve area [AVA] < 1.0 cm2) and normal left ventricular ejection fraction (LVEF). Patients were classified as: high-gradient (HG, mean gradient ≥ 40 mmHg), normal-flow low-gradient (NFLG, mean gradient < 40 mmHg, indexed systolic volume (SVi) > 35 ml/m2) and LFLG (mean gradient < 40 mmHg, SVi ≤ 35 ml/m2). Results: Of 1,391 patients, 147 (10.5%) had LFLG, 752 (54.1%) HG, and 492 (35.4%) NFLG. Echocardiographic parameters of the LFLG group showed similar AVA to the HG group but with less severity in the dimensionless index, calcification, and hypertrophy. The HG group required AVR earlier than NFLG (p < 0.001) and LFLG (p < 0.001), with no differences between LFLG and NFLG groups (p = 0.358). Overall mortality was 27.7% (CI 95% 25.3-30.1) with no differences among groups (p = 0.319). The impact of AVR in terms of overall mortality reduction was observed the most in patients with HG (hazard ratio [HR]: 0.17; 95% CI: 0.12-0.23; p < 0.001), followed by patients with LFLG (HR: 0.25; 95% CI: 0.13-0.49; p < 0.001), and finally patients with NFLG (HR: 0.29; 95% CI: 0.20-0.44; p < 0.001), with a risk reduction of 84, 75, and 71%, respectively. Conclusions: Paradoxical LFLG AS affects 10.5% of severe AS, and has a lower need for AVR than the HG group and similar to the NFLG group, with no differences in mortality. AVR had a lower impact on LFLG AS compared with HG AS. Therefore, the findings of the present study showed LFLG AS to have an intermediate clinical risk profile between the HG and NFHG groups.

19.
J Cardiovasc Magn Reson ; 24(1): 20, 2022 03 28.
Article in English | MEDLINE | ID: mdl-35346239

ABSTRACT

BACKGROUND: Patency of the false lumen in chronic aortic dissection (AD) is associated with aortic dilation and long-term aortic events. However, predictors of adverse outcomes in this population are limited. The aim of this study was to evaluate the relationship between aortic growth rate and false lumen flow dynamics and biomechanics in patients with chronic, patent AD. METHODS: Patients with a chronic AD with patent false lumen in the descending aorta and no genetic connective tissue disorder underwent an imaging follow-up including a contrast-enhanced 4D flow cardiovascular magnetic resonance (CMR) protocol and two consecutive computed tomography angiograms (CTA) acquired at least 1 year apart. A comprehensive analysis of anatomical features (including thrombus quantification), and false lumen flow dynamics and biomechanics (pulse wave velocity) was performed. RESULTS: Fifty-four consecutive patients with a chronic, patent false lumen in the descending aorta were included (35 surgically-treated type A AD with residual tear and 19 medically-treated type B AD). Median follow-up was 40 months. The in-plane rotational flow, pulse wave velocity and the percentage of thrombus in the false lumen were positively related to aortic growth rate (p = 0.006, 0.017, and 0.037, respectively), whereas wall shear stress showed a trend for a positive association (p = 0.060). These results were found irrespectively of the type of AD. CONCLUSIONS: In patients with chronic AD and patent false lumen of the descending aorta, rotational flow, pulse wave velocity and wall shear stress are positively related to aortic growth rate, and should be implemented in the follow-up algorithm of these patients. Further prospective studies are needed to confirm if the assessment of these parameters helps to identify patients at higher risk of adverse clinical events.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Vascular Stiffness , Aortic Dissection/diagnostic imaging , Humans , Magnetic Resonance Spectroscopy , Predictive Value of Tests , Pulse Wave Analysis
20.
J Clin Med ; 11(2)2022 Jan 17.
Article in English | MEDLINE | ID: mdl-35054153

ABSTRACT

Multimodality imaging is the basis of the diagnosis, follow-up, and surgical management of bicuspid aortic valve (BAV) patients. Transthoracic echocardiography (TTE) is used in our clinical routine practice as a first line imaging for BAV diagnosis, valvular phenotyping and function, measurement of thoracic aorta, exclusion of other aortic malformations, and for the assessment of complications such are infective endocarditis and aortic. Nevertheless, TTE is less useful if we want to assess accurately other aortic segments such as mid-distal ascending aorta, where computed tomography (CT) and magnetic resonance (CMR) could improve the precision of aorta size measurement by multiplanar reconstructions. A major advantage of CT is its superior spatial resolution, which affords a better definition of valve morphology and calcification, accuracy, and reproducibility of ascending aorta size, and allows for coronary artery assessment. Moreover, CMR offers the opportunity of being able to evaluate aortic functional properties and blood flow patterns. In this setting, new developed sequences such as 4D-flow may provide new parameters to predict events during follow up. The integration of all multimodality information facilitates a comprehensive evaluation of morphologic and dynamic features, stratification of the risk, and therapy guidance of this cohort of patients.

SELECTION OF CITATIONS
SEARCH DETAIL
...