ABSTRACT

The objective of this research was to apply Fourier transform infrared spectroscopy (FTIR) and tunable infrared laser differential absorption spectroscopy (TILDAS) for measuring selected gaseous constituents in mainstream (MS) and sidestream (SS) smoke for experimental cigarettes designed to reduce MS CO using iron oxide cigarette papers. These two complimentary analytical techniques are well suited for providing per puff smoke deliveries and intra-puff evolution profiles in cigarette smoke respectively. The quad quantum cascade (QC) laser high resolution infrared spectroscopy system has the necessary temporal and spectral resolution and whole smoke analysis capabilities to provide detailed information for CO and CO(2) as they are being formed in both MS and SS smoke. The QC laser system has an optimal data rate of 20 Hz and a unique puffing system, with a square wave shaped puff, that allows whole smoke to enter an 18 m, 0.3 L multi-pass gas cell in real time (0.1s cell response time) requiring no syringe or Cambridge filter pad. Another similar multi-pass gas cell with a 36 m pathlength simultaneously monitors the sidestream cigarette smoke. The smoke from experimental cigarettes manufactured with two types of iron oxide papers were compared to the smoke from cigarettes manufactured similarly without iron oxide in the paper using both instrument systems. The delivery per puff determined by the QC laser method agreed with FTIR results. MS CO intra-puff evolution profiles for iron oxide prototype cigarettes demonstrated CO reduction when compared to cigarettes without iron oxide paper. Additionally, both CO and CO(2) intra-puff evolution profiles of the cigarettes with iron oxide paper showed a significant reduction at the initial portion of the 2 s puff not observed in the non-iron oxide prototype cigarettes. This effect also was observed for ammonia and ethylene, suggesting that physical parameters such as paper porosity and burn rate are important. The SS CO and CO(2) deliveries for the experimental cigarettes evaluated remained unaffected. The iron oxide paper technology remains under development and continues to be evaluated.


Subject(s)
Carbon Dioxide/analysis , Carbon Monoxide/analysis , Ferric Compounds , Paper , Smoking , Spectrum Analysis/methods , Lasers , Quantum Theory , Spectrum Analysis/instrumentation
2.
Spectrochim Acta A Mol Biomol Spectrosc ; 63(5): 994-1001, 2006 Apr.
Article in English | MEDLINE | ID: mdl-16490384

ABSTRACT

Although nitrogen dioxide (NO(2)) has been previously reported to be present in cigarette smoke, the concentration estimates were derived from kinetic calculations or from measurements of aged smoke, where NO(2) was formed some time after the puff was taken. The objective of this work was to use tunable infrared laser differential absorption spectroscopy (TILDAS) equipped with a quantum cascade (QC) laser to determine if NO(2) could be detected and quantified in a fresh puff of cigarette smoke. A temporal resolution of approximately 0.16s allowed measurements to be taken directly as the NO(2) was formed during the puff. Sidestream cigarette smoke was sampled to determine if NO(2) could be detected using TILDAS. Experiments were conducted using 2R4F Kentucky Reference cigarettes with and without a Cambridge filter pad. NO(2) was detected only in the lighting puff of whole mainstream smoke (without a Cambridge filter pad), with no NO(2) detected in the subsequent puffs. The measurement precision was approximately 1.0 ppbVHz(-1/2), which allows a detection limit of approximately 0.2 ng in a 35 ml puff volume. More NO(2) was generated in the lighting puff using a match or blue flame lighter (29+/-21 ng) than when using an electric lighter (9+/-3 ng). In the presence of a Cambridge filter pad, NO(2) was observed in the gas phase mainstream smoke for every puff (total of 200+/-30 ng/cigarette) and is most likely due to smoke chemistry taking place on the Cambridge filter pad during the smoke collection process. Nitrogen dioxide was observed continuously in the sidestream smoke starting with the lighting puff.


Subject(s)
Chemistry Techniques, Analytical/instrumentation , Lasers , Nicotiana/chemistry , Nitrogen Dioxide/analysis , Smoke/analysis , Spectrophotometry, Infrared , Chemistry Techniques, Analytical/methods , Humans , Quantum Theory , Spectrophotometry, Infrared/instrumentation , Spectrophotometry, Infrared/methods