Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Biomech Model Mechanobiol ; 16(1): 97-115, 2017 02.
Article in English | MEDLINE | ID: mdl-27440126

ABSTRACT

Hemodynamics are believed to play an important role in the initiation of cerebral aneurysms. In particular, studies have focused on wall shear stress (WSS), which is a key regulator of vascular biology and pathology. In line with the observation that aneurysms predominantly occur at regions of high WSS, such as bifurcation apices or outer walls of vascular bends, correlations have been found between the aneurysm initiation site and high WSS. The aim of our study was to analyze the WSS field at an aneurysm initiation site that was neither a bifurcation apex nor the outer wall of a vascular bend. Ten cases with aneurysms on the A1 segment of the anterior cerebral artery were analyzed and compared with ten controls. Aneurysms were virtually removed from the vascular models of the cases to mimic the pre-aneurysm geometry. Computational fluid dynamics (CFD) simulations were created to assess the magnitude, gradient, multidirectionality, and pulsatility of the WSS. To aid the inter-subject comparison of hemodynamic variables, we mapped the branch surfaces onto a two-dimensional parametric space. This approach made it possible to view the whole branch at once for qualitative evaluation. It also allowed us to empirically define a patch for quantitative analysis, which was consistent among subjects and encapsulated the aneurysm initiation sites in our dataset. To test the sensitivity of our results, CFD simulations were repeated with a second independent observer virtually removing the aneurysms and with a 20 % higher flow rate at the inlet. We found that branches harboring aneurysms were characterized by high WSS and high WSS gradients. Among all assessed variables, the aneurysm initiation site most consistently coincided with peaks of temporal variation in the WSS magnitude.


Subject(s)
Intracranial Aneurysm/pathology , Models, Cardiovascular , Stress, Mechanical , Hemodynamics , Humans , Hydrodynamics , Shear Strength
2.
AJNR Am J Neuroradiol ; 37(12): 2293-2298, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27633810

ABSTRACT

BACKGROUND AND PURPOSE: Our aim was to assess the performance of flow-diverter stents. The pre- and end-of-treatment angiographies are commonly compared. However, the arterial flow rate may change between acquisitions; therefore, a better understanding of its influence on the local intra-aneurysmal hemodynamics before and after flow-diverter stent use is required. MATERIALS AND METHODS: Twenty-five image-based aneurysm models extracted from 3D rotational angiograms were conditioned for computational fluid dynamics simulations. Pulsatile simulations were performed at different arterial flow rates, covering a wide possible range of physiologic flows among 1-5 mL/s. The effect of flow-diverter stents on intra-aneurysmal hemodynamics was numerically simulated with a porous medium model. Spatiotemporal-averaged intra-aneurysmal flow velocity and flow rate were calculated for each case to quantify the hemodynamics after treatment. The short-term flow-diverter stent performance was characterized by the relative velocity reduction inside the aneurysm. RESULTS: Spatiotemporal-averaged intra-aneurysmal flow velocity before and after flow-diverter stent use is linearly proportional to the mean arterial flow rate (minimum R2 > 0.983 of the linear regression models for untreated and stented models). Relative velocity reduction asymptotically decreases with increasing mean arterial flow rate. When the most probable range of arterial flow rate was considered (3-5 mL/s), instead of the wide possible flow range, the mean SD of relative velocity reduction was reduced from 3.6% to 0.48%. CONCLUSIONS: Both intra-aneurysmal aneurysm velocity and flow-diverter stent performance depend on the arterial flow rate. The performance could be considered independent of the arterial flow rates within the most probable range of physiologic flows.


Subject(s)
Blood Flow Velocity/physiology , Endovascular Procedures/instrumentation , Intracranial Aneurysm/therapy , Models, Cardiovascular , Humans , Hydrodynamics , Stents
3.
Ann Biomed Eng ; 43(1): 154-67, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25118668

ABSTRACT

Validation studies are prerequisites for computational fluid dynamics (CFD) simulations to be accepted as part of clinical decision-making. This paper reports on the 2011 edition of the Virtual Intracranial Stenting Challenge. The challenge aimed to assess the reproducibility with which research groups can simulate the velocity field in an intracranial aneurysm, both untreated and treated with five different configurations of high-porosity stents. Particle imaging velocimetry (PIV) measurements were obtained to validate the untreated velocity field. Six participants, totaling three CFD solvers, were provided with surface meshes of the vascular geometry and the deployed stent geometries, and flow rate boundary conditions for all inlets and outlets. As output, they were invited to submit an abstract to the 8th International Interdisciplinary Cerebrovascular Symposium 2011 (ICS'11), outlining their methods and giving their interpretation of the performance of each stent configuration. After the challenge, all CFD solutions were collected and analyzed. To quantitatively analyze the data, we calculated the root-mean-square error (RMSE) over uniformly distributed nodes on a plane slicing the main flow jet along its axis and normalized it with the maximum velocity on the slice of the untreated case (NRMSE). Good agreement was found between CFD and PIV with a NRMSE of 7.28%. Excellent agreement was found between CFD solutions, both untreated and treated. The maximum difference between any two groups (along a line perpendicular to the main flow jet) was 4.0 mm/s, i.e. 4.1% of the maximum velocity of the untreated case, and the average NRMSE was 0.47% (range 0.28-1.03%). In conclusion, given geometry and flow rates, research groups can accurately simulate the velocity field inside an intracranial aneurysm-as assessed by comparison with in vitro measurements-and find excellent agreement on the hemodynamic effect of different stent configurations.


Subject(s)
Hydrodynamics , Intracranial Aneurysm/physiopathology , Patient-Specific Modeling , Stents , Cerebrovascular Circulation , Computer Simulation , Hemodynamics , Humans , Reproducibility of Results
4.
J Biomech ; 47(1): 178-85, 2014 Jan 03.
Article in English | MEDLINE | ID: mdl-24262847

ABSTRACT

Computational fluid dynamics (CFD) simulations can be employed to gain a better understanding of hemodynamics in cerebral aneurysms and improve diagnosis and treatment. However, introduction of CFD techniques into clinical practice would require faster simulation times. The aim of this study was to evaluate the use of computationally inexpensive steady flow simulations to approximate the aneurysm's wall shear stress (WSS) field. Two experiments were conducted. Experiment 1 compared for two cases the time-averaged (TA), peak systole (PS) and end diastole (ED) WSS field between steady and pulsatile flow simulations. The flow rate waveform imposed at the inlet was varied to account for variations in heart rate, pulsatility index, and TA flow rate. Consistently across all flow rate waveforms, steady flow simulations accurately approximated the TA, but not the PS and ED, WSS field. Following up on experiment 1, experiment 2 tested the result for the TA WSS field in a larger population of 20 cases covering a wide range of aneurysm volumes and shapes. Steady flow simulations approximated the space-averaged WSS with a mean error of 4.3%. WSS fields were locally compared by calculating the absolute error per node of the surface mesh. The coefficient of variation of the root-mean-square error over these nodes was on average 7.1%. In conclusion, steady flow simulations can accurately approximate the TA WSS field of an aneurysm. The fast computation time of 6 min per simulation (on 64 processors) could help facilitate the introduction of CFD into clinical practice.


Subject(s)
Hemodynamics/physiology , Hydrodynamics , Intracranial Aneurysm/physiopathology , Models, Cardiovascular , Algorithms , Computer Simulation , Humans , Models, Biological , Pulsatile Flow , Reproducibility of Results , Shear Strength , Stress, Mechanical , Systole/physiology
5.
AJNR Am J Neuroradiol ; 34(4): 816-22, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23019173

ABSTRACT

BACKGROUND AND PURPOSE: Effects of blood flow modification by flow diverters are observed to lead often to aneurysm thrombosis and reverse remodeling. For this process, to further understand the potential roles of intra-aneurysmal blood pressure changes and aneurysm morphologies, 23 patients were studied by numeric simulation. MATERIALS AND METHODS: 3D imaging of aneurysms of different sizes and shapes, all located at the supraclinoid segment of the ICA (n=23), was prepared for CFD simulations. Hemodynamic variables were calculated for conditions before and after virtual FD implantation, reconstituting a vessel wall scaffold across the aneurysm neck. WSS, velocity, residence time, turnover time, and intra-aneurysmal pressure were assessed statistically. RESULTS: After placement of FDs, significant reductions inside the aneurysm were observed for most hemodynamic variables (P<.01) except mean intra-aneurysmal pressures. For minimum/maximum intra-aneurysmal pressure values, small but significant changes were found; however, they were considered too small to be of relevance. CONCLUSIONS: Calculations in 23 cases did not reveal significant intra-aneurysmal mean or peak pressure changes, indicating a minor role of pressure changes in the rare event of secondary ruptures after FD use. Other hemodynamic variables (WSS and velocity) exhibited more significant changes, indicating their role in intra-aneurysmal thrombus formation. Size-dependent, significantly higher reduction in WSS (P=.069) and velocity (P=.013) was observed in small aneurysms compared with larger ones. When it came to shape, there were significantly higher reductions in WSS (P=.055) and velocity (P=.065) and a significantly higher increase in turnover time in fusiform aneurysms compared with saccular aneurysms.


Subject(s)
Cerebrovascular Circulation/physiology , Computer Simulation , Intracranial Aneurysm/physiopathology , Models, Cardiovascular , Blood Flow Velocity/physiology , Blood Pressure/physiology , Databases, Factual , Endovascular Procedures , Hemodynamics/physiology , Humans , Intracranial Aneurysm/classification , Intracranial Aneurysm/therapy , Thrombosis/physiopathology , Vascular Resistance/physiology
6.
AJNR Am J Neuroradiol ; 32(3): 581-6, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21183614

ABSTRACT

BACKGROUND AND PURPOSE: Patient-specific simulations of the hemodynamics in intracranial aneurysms can be constructed by using image-based vascular models and CFD techniques. This work evaluates the impact of the choice of imaging technique on these simulations. MATERIALS AND METHODS: Ten aneurysms, imaged with 3DRA and CTA, were analyzed to assess the reproducibility of geometric and hemodynamic variables across the 2 modalities. RESULTS: Compared with 3DRA models, we found that CTA models often had larger aneurysm necks (P = .05) and that most of the smallest vessels (between 0.7 and 1.0 mm in diameter) could not be reconstructed successfully with CTA. With respect to the values measured in the 3DRA models, the flow rate differed by 14.1 ± 2.8% (mean ± SE) just proximal to the aneurysm and 33.9 ± 7.6% at the aneurysm neck. The mean WSS on the aneurysm differed by 44.2 ± 6.0%. Even when normalized to the parent vessel WSS, a difference of 31.4 ± 9.9% remained, with the normalized WSS in most cases being larger in the CTA model (P = .04). Despite these substantial differences, excellent agreement (κ ≥ 0.9) was found for qualitative variables that describe the flow field, such as the structure of the flow pattern and the flow complexity. CONCLUSIONS: Although relatively large differences were found for all evaluated quantitative hemodynamic variables, the main flow characteristics were reproduced across imaging modalities.


Subject(s)
Cerebral Angiography/methods , Cerebrovascular Circulation , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/physiopathology , Models, Cardiovascular , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Blood Flow Velocity , Computer Simulation , Female , Humans , Male , Middle Aged , Reproducibility of Results , Rotation , Sensitivity and Specificity
7.
Article in English | MEDLINE | ID: mdl-21095844

ABSTRACT

AngioLab is a software tool developed within the GIMIAS framework and is part of a more ambitious pipeline for the integrated management of cerebral aneurysms. AngioLab currently includes three plug-ins: angio segmentation, angio morphology and stenting, as well as supports advanced rendering techniques for the visualization of virtual angiographies. In December 2009, 23 clinicians completed an evaluation questionnaire about AngioLab. This activity was part of a teaching course held during the 2(nd) European Society for Minimally Invasive Neurovascular Treatment (ESMINT) Teaching Course held at the Universitat Pompeu Fabra, Barcelona, Spain. The Automated Morphological Analysis (angio morphology plug-in) and the Endovascular Treatment Planning (stenting plug-in) were evaluated. In general, the results provided by these tools were considered as relevant and as an emerging need in their clinical field.


Subject(s)
Intracranial Aneurysm , Software , Computer Simulation , Humans , Patient Care Planning
8.
Article in English | MEDLINE | ID: mdl-21096183

ABSTRACT

Hemodynamics play an important role in the pathogenesis of intracranial aneurysms and patient-specific computational hemodynamic simulations could provide valuable information to clinicians. Transient simulations that capture the pulsatility of blood flow are commonly used for research purposes. However, steady-state simulations might provide enough information at a lower computational cost, which could help facilitate the introduction of hemodynamic simulations into clinical practice. In this study, we compared steady-state simulations to transient simulations for two aneurysms. The effect of a change in flow rate waveform was investigated and virtual treatment techniques were employed to compare post-treatment flow reduction predictions. We found that the difference in the time-averaged wall shear stress on the aneurysm was less than 5% and the distribution of wall shear stress was qualitatively assessed to be very similar.


Subject(s)
Intracranial Aneurysm/physiopathology , Aneurysm , Blood Flow Velocity , Carotid Artery, Internal/pathology , Cerebral Angiography/methods , Cerebrovascular Circulation , Computer Simulation , Exercise , Hemodynamics , Humans , Intracranial Aneurysm/diagnosis , Middle Cerebral Artery/physiopathology , Models, Cardiovascular , Models, Statistical , Stress, Mechanical , Time Factors
9.
Philos Trans A Math Phys Eng Sci ; 368(1921): 2961-82, 2010 Jun 28.
Article in English | MEDLINE | ID: mdl-20478916

ABSTRACT

In the last few years, some of the visionary concepts behind the virtual physiological human began to be demonstrated on various clinical domains, showing great promise for improving healthcare management. In the current work, we provide an overview of image- and biomechanics-based techniques that, when put together, provide a patient-specific pipeline for the management of intracranial aneurysms. The derivation and subsequent integration of morphological, morphodynamic, haemodynamic and structural analyses allow us to extract patient-specific models and information from which diagnostic and prognostic descriptors can be obtained. Linking such new indices with relevant clinical events should bring new insights into the processes behind aneurysm genesis, growth and rupture. The development of techniques for modelling endovascular devices such as stents and coils allows the evaluation of alternative treatment scenarios before the intervention takes place and could also contribute to the understanding and improved design of more effective devices. A key element to facilitate the clinical take-up of all these developments is their comprehensive validation. Although a number of previously published results have shown the accuracy and robustness of individual components, further efforts should be directed to demonstrate the diagnostic and prognostic efficacy of these advanced tools through large-scale clinical trials.


Subject(s)
Disease Management , Intracranial Aneurysm/therapy , Aneurysm, Ruptured/diagnosis , Aneurysm, Ruptured/therapy , Biomechanical Phenomena , Cerebral Angiography , Diagnostic Imaging , Equipment and Supplies , Hemodynamics , Humans , Image Interpretation, Computer-Assisted , Intracranial Aneurysm/diagnosis , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/physiopathology , Models, Anatomic , Models, Biological , Movement , Precision Medicine , Prognosis , Stents , User-Computer Interface
SELECTION OF CITATIONS
SEARCH DETAIL
...