Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
Add more filters










Publication year range
1.
iScience ; 25(10): 105261, 2022 Oct 21.
Article in English | MEDLINE | ID: mdl-36274949

ABSTRACT

Ant-plant defensive mutualism is a widely studied phenomenon, where ants protect their host plants (myrmecophytes) against herbivores in return for the provision of nesting sites and food. However, few studies addressed the influence of ant colonization and herbivory on the plant's metabolism. We chose the Amazonian plant Tococa quadrialata, living in association with Azteca cf. tonduzi ants for an ant-exclusion study to reveal the chemistry behind this symbiosis. We found that colonized plants did not only benefit from protection but also from increased amino acid and nitrogen content, enabling better performance even in an herbivore-free environment. In contrast, ant-deprived T. quadrialata plants accumulated more ellagitannins, a major class of constitutive defense compounds. Moreover, herbivory-induced jasmonate-mediated defense responses, including the upregulation of signaling and defense genes and the emission of volatiles irrespective of colonization status. Altogether, we show how ant-colonization can influence the general and defense-related metabolism and performance of myrmecophytes.

2.
Rapid Commun Mass Spectrom ; 36(13): e9296, 2022 Jul 15.
Article in English | MEDLINE | ID: mdl-35289456

ABSTRACT

RATIONALE: Information on the isotopic composition of nitrous oxide (N2 O) at natural abundance supports the identification of its source and sink processes. In recent years, a number of mass spectrometric and laser spectroscopic techniques have been developed and are increasingly used by the research community. Advances in this active research area, however, critically depend on the availability of suitable N2 O isotope Reference Materials (RMs). METHODS: Within the project Metrology for Stable Isotope Reference Standards (SIRS), seven pure N2 O isotope RMs have been developed and their 15 N/14 N, 18 O/16 O, 17 O/16 O ratios and 15 N site preference (SP) have been analysed by specialised laboratories against isotope reference materials. A particular focus was on the 15 N site-specific isotopic composition, as this measurand is both highly diagnostic for source appointment and challenging to analyse and link to existing scales. RESULTS: The established N2 O isotope RMs offer a wide spread in delta (δ) values: δ15 N: 0 to +104‰, δ18 O: +39 to +155‰, and δ15 NSP : -4 to +20‰. Conversion and uncertainty propagation of δ15 N and δ18 O to the Air-N2 and VSMOW scales, respectively, provides robust estimates for δ15 N(N2 O) and δ18 O(N2 O), with overall uncertainties of about 0.05‰ and 0.15‰, respectively. For δ15 NSP , an offset of >1.5‰ compared with earlier calibration approaches was detected, which should be revisited in the future. CONCLUSIONS: A set of seven N2 O isotope RMs anchored to the international isotope-ratio scales was developed that will promote the implementation of the recommended two-point calibration approach. Particularly, the availability of δ17 O data for N2 O RMs is expected to improve data quality/correction algorithms with respect to δ15 NSP and δ15 N analysis by mass spectrometry. We anticipate that the N2 O isotope RMs will enhance compatibility between laboratories and accelerate research progress in this emerging field.


Subject(s)
Nitrous Oxide , Calibration , Mass Spectrometry/methods , Nitrous Oxide/analysis , Oxygen Isotopes/analysis , Reference Standards
4.
Rapid Commun Mass Spectrom ; 35(4): e9006, 2021 Feb 28.
Article in English | MEDLINE | ID: mdl-33201519

ABSTRACT

RATIONALE: The stable carbon isotopic (δ13 C) reference material (RM) LSVEC Li2 CO3 has been found to be unsuitable for δ13 C standardization work because its δ13 C value increases with exposure to atmospheric CO2 . A new CaCO3 RM, USGS44, has been prepared to alleviate this situation. METHODS: USGS44 was prepared from 8 kg of Merck high-purity CaCO3 . Two sets of δ13 C values of USGS44 were determined. The first set of values was determined by online combustion, continuous-flow (CF) isotope-ratio mass spectrometry (IRMS) of NBS 19 CaCO3 (δ13 CVPDB = +1.95 milliurey (mUr) exactly, where mUr = 0.001 = 1‰), and LSVEC Li2 CO3 (δ13 CVPDB = -46.6 mUr exactly), and normalized to the two-anchor δ13 CVPDB-LSVEC isotope-delta scale. The second set of values was obtained by dual-inlet (DI)-IRMS of CO2 evolved by reaction of H3 PO4 with carbonates, corrected for cross contamination, and normalized to the single-anchor δ13 CVPDB scale. RESULTS: USGS44 is stable and isotopically homogeneous to within 0.02 mUr in 100-µg amounts. It has a δ13 CVPDB-LSVEC value of -42.21 ± 0.05 mUr. Single-anchor δ13 CVPDB values of -42.08 ± 0.01 and -41.99 ± 0.02 mUr were determined by DI-IRMS with corrections for cross contamination. CONCLUSIONS: The new high-purity, well-homogenized calcium carbonate isotopic reference material USGS44 is stable and has a δ13 CVPDB-LSVEC value of -42.21 ± 0.05 mUr for both EA/IRMS and DI-IRMS measurements. As a carbonate relatively depleted in 13 C, it is intended for daily use as a secondary isotopic reference material to normalize stable carbon isotope delta measurements to the δ13 CVPDB-LSVEC scale. It is useful in quantifying drift with time, determining mass-dependent isotopic fractionation (linearity correction), and adjusting isotope-ratio-scale contraction. Due to its fine grain size (smaller than 63 µm), it is not suitable as a δ18 O reference material. A δ13 CVPDB-LSVEC value of -29.99 ± 0.05 mUr was determined for NBS 22 oil.

5.
Rapid Commun Mass Spectrom ; 33(4): 343-350, 2019 Feb 28.
Article in English | MEDLINE | ID: mdl-30452095

ABSTRACT

RATIONALE: Stable hydrogen and carbon isotope ratios of methoxy groups (OCH3 ) of plant organic matter have many potential applications in biogeochemical, atmospheric and food research. So far, most of the analyses of plant methoxy groups by isotope ratio mass spectrometry have employed liquid iodomethane (CH3 I) as the reference material to normalise stable isotope measurements of these moieties to isotope-δ scales. However, comparisons of measurements of stable hydrogen and carbon isotopes of plant methoxy groups are still hindered by the lack of suitable reference materials. METHODS: We have investigated two methyl sulfate salts (HUBG1 and HUBG2), which exclusively contain carbon and hydrogen from one methoxy group, for their suitability as methoxy reference materials. Firstly, the stable hydrogen and carbon isotope values of the bulk compounds were calibrated against international reference substances by high-temperature conversion- and elemental analyser isotope ratio mass spectrometry (HTC- and EA-IRMS). In a second step these values were compared with values obtained by measurements using gas chromatography/isotope ratio mass spectrometry (GC/IRMS) where prior to analysis the methoxy groups were converted into gaseous iodomethane. RESULTS: The 2 H- and 13 C isotopic abundances of HUBG1 measured by HTC- and EA-IRMS and expressed as δ-values on the usual international scales are -144.5 ± 1.2 mUr (n = 30) and -50.31 ± 0.16 mUr (n = 14), respectively. For HUBG2 we obtained -102.0 ± 1.3 mUr (n = 32) and +1.60 ± 0.12 mUr (n = 16). Furthermore, the values obtained by GC/IRMS were in good agreement with the HTC- and EA-IRMS values. CONCLUSIONS: We suggest that both methyl sulfates are suitable reference materials for normalisation of isotope measurements of carbon of plant methoxy groups to isotope-δ scales and for inter-laboratory calibration. For stable hydrogen isotope measurements, we suggest that in addition to HUBG1 and HUBG2 additional reference materials are required to cover the full range of plant methoxy groups reported so far.

6.
Rapid Commun Mass Spectrom ; 31(6): 475-484, 2017 Mar 30.
Article in English | MEDLINE | ID: mdl-27984667

ABSTRACT

RATIONALE: Accurate hydrogen isotopic analysis of halogen- and sulfur-bearing organics has not been possible with traditional high-temperature conversion (HTC) because the formation of hydrogen-bearing reaction products other than molecular hydrogen (H2 ) is responsible for non-quantitative H2 yields and possible hydrogen isotopic fractionation. Our previously introduced, new chromium-based EA-Cr/HTC-IRMS (Elemental Analyzer-Chromium/High-Temperature Conversion Isotope Ratio Mass Spectrometry) technique focused primarily on nitrogen-bearing compounds. Several technical and analytical issues concerning halogen- and sulfur-bearing samples, however, remained unresolved and required further refinement of the reactor systems. METHODS: The EA-Cr/HTC reactor was substantially modified for the conversion of halogen- and sulfur-bearing samples. The performance of the novel conversion setup for solid and liquid samples was monitored and optimized using a simultaneously operating dual-detection system of IRMS and ion trap MS. The method with several variants in the reactor, including the addition of manganese metal chips, was evaluated in three laboratories using EA-Cr/HTC-IRMS (on-line method) and compared with traditional uranium-reduction-based conversion combined with manual dual-inlet IRMS analysis (off-line method) in one laboratory. RESULTS: The modified EA-Cr/HTC reactor setup showed an overall H2 -recovery of more than 96% for all halogen- and sulfur-bearing organic compounds. All results were successfully normalized via two-point calibration with VSMOW-SLAP reference waters. Precise and accurate hydrogen isotopic analysis was achieved for a variety of organics containing F-, Cl-, Br-, I-, and S-bearing heteroelements. The robust nature of the on-line EA-Cr/HTC technique was demonstrated by a series of 196 consecutive measurements with a single reactor filling. CONCLUSIONS: The optimized EA-Cr/HTC reactor design can be implemented in existing analytical equipment using commercially available material and is universally applicable for both heteroelement-bearing and heteroelement-free organic-compound classes. The sensitivity and simplicity of the on-line EA-Cr/HTC-IRMS technique provide a much needed tool for routine hydrogen-isotope source tracing of organic contaminants in the environment. Copyright © 2016 John Wiley & Sons, Ltd.

7.
Rapid Commun Mass Spectrom ; 30(23): 2487-2496, 2016 Dec 15.
Article in English | MEDLINE | ID: mdl-27605461

ABSTRACT

RATIONALE: In the last few years, the study of N2 O site-specific nitrogen isotope composition has been established as a powerful technique to disentangle N2 O emission pathways. This trend has been accelerated by significant analytical progress in the field of isotope ratio mass spectrometry (IRMS) and more recently quantum cascade laser absorption spectroscopy (QCLAS). METHODS: The ammonium nitrate (NH4 NO3 ) decomposition technique provides a strategy to scale the 15 N site-specific (SP ≡ Î´15 Nα - δ15 Nß ) and bulk (δ15 Nbulk  = (δ15 Nα  + Î´15 Nß )/2) isotopic composition of N2 O against the international standard for the 15 N/14 N isotope ratio (AIR-N2 ). Within the current project 15 N fractionation effects during thermal decomposition of NH4 NO3 on the N2 O site preference were studied using static and dynamic decomposition techniques. RESULTS: The validity of the NH4 NO3 decomposition technique to link NH4+ and NO3- moiety-specific δ15 N analysis by IRMS to the site-specific nitrogen isotopic composition of N2 O was confirmed. However, the accuracy of this approach for the calibration of δ15 Nα and δ15 Nß values was found to be limited by non-quantitative NH4 NO3 decomposition in combination with substantially different isotope enrichment factors for the conversion of the NO3- or NH4+ nitrogen atom into the α or ß position of the N2 O molecule. CONCLUSIONS: The study reveals that the completeness and reproducibility of the NH4 NO3 decomposition reaction currently confine the anchoring of N2 O site-specific isotopic composition to the international isotope ratio scale AIR-N2 . The authors suggest establishing a set of N2 O isotope reference materials with appropriate site-specific isotopic composition, as community standards, to improve inter-laboratory compatibility. Copyright © 2016 John Wiley & Sons, Ltd.

8.
Anal Chem ; 88(8): 4294-302, 2016 Apr 19.
Article in English | MEDLINE | ID: mdl-26974360

ABSTRACT

An international project developed, quality-tested, and determined isotope-δ values of 19 new organic reference materials (RMs) for hydrogen, carbon, and nitrogen stable isotope-ratio measurements, in addition to analyzing pre-existing RMs NBS 22 (oil), IAEA-CH-7 (polyethylene foil), and IAEA-600 (caffeine). These new RMs enable users to normalize measurements of samples to isotope-δ scales. The RMs span a range of δ(2)H(VSMOW-SLAP) values from -210.8 to +397.0 mUr or ‰, for δ(13)C(VPDB-LSVEC) from -40.81 to +0.49 mUr and for δ(15)N(Air) from -5.21 to +61.53 mUr. Many of the new RMs are amenable to gas and liquid chromatography. The RMs include triads of isotopically contrasting caffeines, C16 n-alkanes, n-C20-fatty acid methyl esters (FAMEs), glycines, and l-valines, together with polyethylene powder and string, one n-C17-FAME, a vacuum oil (NBS 22a) to replace NBS 22 oil, and a (2)H-enriched vacuum oil. A total of 11 laboratories from 7 countries used multiple analytical approaches and instrumentation for 2-point isotopic normalization against international primary measurement standards. The use of reference waters in silver tubes allowed direct normalization of δ(2)H values of organic materials against isotopic reference waters following the principle of identical treatment. Bayesian statistical analysis yielded the mean values reported here. New RMs are numbered from USGS61 through USGS78, in addition to NBS 22a. Because of exchangeable hydrogen, amino acid RMs currently are recommended only for carbon- and nitrogen-isotope measurements. Some amino acids contain (13)C and carbon-bound organic (2)H-enrichments at different molecular sites to provide RMs for potential site-specific isotopic analysis in future studies.

9.
Rapid Commun Mass Spectrom ; 30(7): 859-66, 2016 Apr 15.
Article in English | MEDLINE | ID: mdl-26969927

ABSTRACT

RATIONALE: The widely used l-glutamic acid isotopic reference material USGS41, enriched in both (13) C and (15) N, is nearly exhausted. A new material, USGS41a, has been prepared as a replacement for USGS41. METHODS: USGS41a was prepared by dissolving analytical grade l-glutamic acid enriched in (13) C and (15) N together with l-glutamic acid of normal isotopic composition. The δ(13) C and δ(15) N values of USGS41a were directly or indirectly normalized with the international reference materials NBS 19 calcium carbonate (δ(13) CVPDB = +1.95 mUr, where milliurey = 0.001 = 1 ‰), LSVEC lithium carbonate (δ(13) CVPDB = -46.6 mUr), and IAEA-N-1 ammonium sulfate (δ(15) NAir = +0.43 mUr) and USGS32 potassium nitrate (δ(15) N = +180 mUr exactly) by on-line combustion, continuous-flow isotope-ratio mass spectrometry, and off-line dual-inlet isotope-ratio mass spectrometry. RESULTS: USGS41a is isotopically homogeneous; the reproducibility of δ(13) C and δ(15) N is better than 0.07 mUr and 0.09 mUr, respectively, in 200-µg amounts. It has a δ(13) C value of +36.55 mUr relative to VPDB and a δ(15) N value of +47.55 mUr relative to N2 in air. USGS41 was found to be hydroscopic, probably due to the presence of pyroglutamic acid. Experimental results indicate that the chemical purity of USGS41a is substantially better than that of USGS41. CONCLUSIONS: The new isotopic reference material USGS41a can be used with USGS40 (having a δ(13) CVPDB value of -26.39 mUr and a δ(15) NAir value of -4.52 mUr) for (i) analyzing local laboratory isotopic reference materials, and (ii) quantifying drift with time, mass-dependent isotopic fractionation, and isotope-ratio-scale contraction for isotopic analysis of biological and organic materials. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA.


Subject(s)
Carbon Isotopes/analysis , Glutamic Acid/analysis , Glutamic Acid/chemistry , Mass Spectrometry/standards , Nitrogen Isotopes/analysis , Carbon Isotopes/chemistry , Nitrogen Isotopes/chemistry , Reference Standards , Reproducibility of Results
10.
Rapid Commun Mass Spectrom ; 29(9): 878-84, 2015 May 15.
Article in English | MEDLINE | ID: mdl-26377016

ABSTRACT

RATIONALE: High-precision hydrogen isotope ratio analysis of nitrogen-bearing organic materials using high-temperature conversion (HTC) techniques has proven troublesome in the past. Formation of reaction products other than molecular hydrogen (H(2)) has been suspected as a possible cause of incomplete H(2) yield and hydrogen isotopic fractionation. METHODS: The classical HTC reactor setup and a modified version including elemental chromium, both operated at temperatures in excess of 1400 °C, have been compared using a selection of nitrogen-bearing organic compounds, including caffeine. A focus of the experiments was to avoid or suppress hydrogen cyanide (HCN) formation and to reach quantitative H(2) yields. The technique also was optimized to provide acceptable sample throughput. RESULTS: The classical HTC reaction of a number of selected compounds exhibited H(2) yields from 60 to 90 %. Yields close to 100 % were measured for the experiments with the chromium-enhanced reactor. The δ(2)H values also were substantially different between the two types of experiments. For the majority of the compounds studied, a highly significant relationship was observed between the amount of missing H(2) and the number of nitrogen atoms in the molecules, suggesting the pyrolytic formation of HCN as a byproduct. A similar linear relationship was found between the amount of missing H(2) and the observed hydrogen isotopic result, reflecting isotopic fractionation. CONCLUSIONS: The classical HTC technique to produce H(2) from organic materials using high temperatures in the presence of glassy carbon is not suitable for nitrogen-bearing compounds. Adding chromium to the reaction zone improves the yield to 100 % in most cases. The initial formation of HCN is accompanied by a strong hydrogen isotope effect, with the observed hydrogen isotope results on H(2) being substantially shifted to more negative δ(2)H values. The reaction can be understood as an initial disproportionation leading to H(2) and HCN with the HCN-hydrogen systematically enriched in (2)H by more than 50 ‰. In the reaction of HCN with chromium, H(2) and chromium-containing solid residues are formed quantitatively.


Subject(s)
Hydrogen/chemistry , Nitrogen Compounds/analysis , Nitrogen Compounds/chemistry , Hot Temperature , Hydrogen/analysis , Hydrogen Cyanide/chemistry , Mass Spectrometry
11.
Rapid Commun Mass Spectrom ; 24(13): 1821-7, 2010 Jul 15.
Article in English | MEDLINE | ID: mdl-20533311

ABSTRACT

A new method to seal water in silver tubes for use in a TC/EA (thermal conversion/elemental analyzer) reduction unit using a semi-automated sealing apparatus can yield reproducibilities (1 standard deviation) of delta(2)H and delta(18)O measurements of 1.0 per thousand and 0.06 per thousand, respectively. These silver tubes containing reference waters may be preferred for the calibration of H- and O-bearing materials analyzed with a TC/EA reduction unit. The new sealing apparatus employs a computer-controlled stepping motor to produce silver tubes identical in length. The reproducibility of the mass of water sealed in tubes (in a range of 200-400 microg) can be as good as 1%. Approximately 99% of the sealed silver tubes are satisfactory (leak free). Although silver tubes sealed with reference waters are robust and can be shaken or heated to 110 degrees C with no loss of integrity, they should not be frozen because the expansion during the phase transition of water to ice will break the cold seals and all the water will be lost. The tubes should be shipped in insulated containers. This new method eliminates air inclusions and isotopic fractionation of water associated with the loading of water into capsules using a syringe. The method is also more than an order of magnitude faster than preparing water samples in ordinary Ag capsules. Nevertheless, some laboratories may prefer loading water into silver capsules because expensive equipment is not needed, but users of this method are cautioned to apply the necessary corrections for evaporation, back exchange with laboratory atmospheric moisture, and blanks.


Subject(s)
Mass Spectrometry/instrumentation , Mass Spectrometry/methods , Silver/chemistry , Water/chemistry , Deuterium/analysis , Hot Temperature , Oxygen Isotopes/analysis , Reproducibility of Results , Time Factors
13.
Rapid Commun Mass Spectrom ; 23(7): 999-1019, 2009 Apr.
Article in English | MEDLINE | ID: mdl-19263478

ABSTRACT

Internationally distributed organic and inorganic oxygen isotopic reference materials have been calibrated by six laboratories carrying out more than 5300 measurements using a variety of high-temperature conversion techniques (HTC)a in an evaluation sponsored by the International Union of Pure and Applied Chemistry (IUPAC). To aid in the calibration of these reference materials, which span more than 125 per thousand, an artificially enriched reference water (delta(18)O of +78.91 per thousand) and two barium sulfates (one depleted and one enriched in (18)O) were prepared and calibrated relative to VSMOW2b and SLAP reference waters. These materials were used to calibrate the other isotopic reference materials in this study, which yielded: Reference material delta(18)O and estimated combined uncertainty IAEA-602 benzoic acid+71.28 +/- 0.36 per thousand USGS 35 sodium nitrate+56.81 +/- 0.31 per thousand IAEA-NO-3 potassium nitrate+25.32 +/- 0.29 per thousand IAEA-601 benzoic acid+23.14 +/- 0.19 per thousand IAEA-SO-5 barium sulfate+12.13 +/- 0.33 per thousand NBS 127 barium sulfate+8.59 +/- 0.26 per thousand VSMOW2 water 0 per thousand IAEA-600 caffeine-3.48 +/- 0.53 per thousand IAEA-SO-6 barium sulfate-11.35 +/- 0.31 per thousand USGS 34 potassium nitrate-27.78 +/- 0.37 per thousand SLAP water-55.5 per thousand The seemingly large estimated combined uncertainties arise from differences in instrumentation and methodology and difficulty in accounting for all measurement bias. They are composed of the 3-fold standard errors directly calculated from the measurements and provision for systematic errors discussed in this paper. A primary conclusion of this study is that nitrate samples analyzed for delta(18)O should be analyzed with internationally distributed isotopic nitrates, and likewise for sulfates and organics. Authors reporting relative differences of oxygen-isotope ratios (delta(18)O) of nitrates, sulfates, or organic material should explicitly state in their reports the delta(18)O values of two or more internationally distributed nitrates (USGS 34, IAEA-NO-3, and USGS 35), sulfates (IAEA-SO-5, IAEA-SO-6, and NBS 127), or organic material (IAEA-601 benzoic acid, IAEA-602 benzoic acid, and IAEA-600 caffeine), as appropriate to the material being analyzed, had these reference materials been analyzed with unknowns. This procedure ensures that readers will be able to normalize the delta(18)O values at a later time should it become necessary.The high-temperature reduction technique for analyzing delta(18)O and delta(2)H is not as widely applicable as the well-established combustion technique for carbon and nitrogen stable isotope determination. To obtain the most reliable stable isotope data, materials should be treated in an identical fashion; within the same sequence of analyses, samples should be compared with working reference materials that are as similar in nature and in isotopic composition as feasible.


Subject(s)
Hot Temperature , Laboratories/standards , Mass Spectrometry/methods , Nitrates/chemistry , Oxygen Isotopes/chemistry , Sulfates/chemistry , Calibration , Reference Standards , Reproducibility of Results
15.
Rapid Commun Mass Spectrom ; 17(22): 2483-7, 2003.
Article in English | MEDLINE | ID: mdl-14608617

ABSTRACT

Analytical grade L-glutamic acid is chemically stable and has a C/N mole ratio of 5, which is close to that of many of natural biological materials, such as blood and animal tissue. Two L-glutamic acid reference materials with substantially different 13C and 15N abundances have been prepared for use as organic reference materials for C and N isotopic measurements. USGS40 is analytical grade L-glutamic acid and has a delta13C value of -26.24 per thousand relative to VPDB and a delta15N value of -4.52 per thousand relative to N2 in air. USGS41 was prepared by dissolving analytical grade L-glutamic acid with L-glutamic acid enriched in 13C and 15N. USGS41 has a delta13C value of +37.76 per thousand and a delta15N value of +47.57 per thousand. The delta13C and delta15N values of both materials were measured against the international reference materials NBS 19 calcium carbonate (delta13C=+1.95 per thousand ), L-SVEC lithium carbonate (delta13C=-46.48 per thousand ), IAEA-N-1 ammonium sulfate (delta15N=0.43 per thousand ), and USGS32 potassium nitrate (delta15N=180 per thousand ) by on-line combustion continuous-flow and off-line dual-inlet isotope-ratio mass spectrometry. Both USGS40 and USGS41 are isotopically homogeneous; reproducibility of delta13C is better than 0.13 per thousand, and that of delta15N is better than 0.13 per thousand in 100-microg amounts. These two isotopic reference materials can be used for (i) calibrating local laboratory reference materials, and (ii) quantifying drift with time, mass-dependent fractionations, and isotope-ratio-scale contraction in the isotopic analysis of various biological materials. Isotopic results presented in this paper yield a delta13C value for NBS 22 oil of -29.91 per thousand, in contrast to the commonly accepted value of -29.78 per thousand for which off-line blank corrections probably have not been quantified satisfactorily.

SELECTION OF CITATIONS