1.
Rev Sci Instrum ; 86(11): 113701, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26628138

ABSTRACT

Imaging systems that include a specific source, imaging concept, geometry, and detector have unique properties such as signal-to-noise ratio, dynamic range, spatial resolution, distortions, and contrast. Some of these properties are inherently connected, particularly dynamic range and spatial resolution. It must be emphasized that spatial resolution is not a single number but must be seen in the context of dynamic range and consequently is better described by a function or distribution. We introduce the "dynamic granularity" G(dyn) as a standardized, objective relation between a detector's spatial resolution (granularity) and dynamic range for complex imaging systems in a given environment rather than the widely found characterization of detectors such as cameras or films by themselves. This relation can partly be explained through consideration of the signal's photon statistics, background noise, and detector sensitivity, but a comprehensive description including some unpredictable data such as dust, damages, or an unknown spectral distribution will ultimately have to be based on measurements. Measured dynamic granularities can be objectively used to assess the limits of an imaging system's performance including all contributing noise sources and to qualify the influence of alternative components within an imaging system. This article explains the construction criteria to formulate a dynamic granularity and compares measured dynamic granularities for different detectors used in the X-ray backlighting scheme employed at Sandia's Z-Backlighter facility.

2.
Appl Opt ; 54(16): 5147-61, 2015 Jun 01.
Article in English | MEDLINE | ID: mdl-26192678

ABSTRACT

We present calculations for the field of view (FOV), image fluence, image monochromaticity, spectral acceptance, and image aberrations for spherical crystal microscopes, which are used as self-emission imaging or backlighter systems at large-scale high energy density physics facilities. Our analytic results are benchmarked with ray-tracing calculations as well as with experimental measurements from the 6.151 keV backlighter system at Sandia National Laboratories. The analytic expressions can be used for x-ray source positions anywhere between the Rowland circle and object plane. This enables quick optimization of the performance of proposed but untested, bent-crystal microscope systems to find the best compromise between FOV, image fluence, and spatial resolution for a particular application.

3.
Rev Sci Instrum ; 82(5): 053101, 2011 May.
Article in English | MEDLINE | ID: mdl-21639486

ABSTRACT

Experiments dedicated to the characterization of plasma mirrors with a high energy, single shot short-pulse laser were performed at the 100 TW target area of the Z-Backlighter Facility at Sandia National Laboratories. A suite of beam diagnostics was used to characterize a high energy laser pulse with a large aperture through focus imaging setup. By varying the fluence on the plasma mirror around the plasma ignition threshold, critical performance parameters were determined and a more detailed understanding of the way in which a plasma mirror works could be deduced. It was found, that very subtle variations in the laser near field profile will have strong effects on the reflected pulse if the maximum fluence on the plasma mirror approaches the plasma ignition threshold.

4.
Opt Express ; 14(23): 10957-69, 2006 Nov 13.
Article in English | MEDLINE | ID: mdl-19529509

ABSTRACT

An optical surface of variable concave parabolic shape and a clear aperture of 30 mm was created using two rings to deform a flat 50.8 mm diameter mirror. The deformable mirror assembly was modeled using finite element analysis software as well as analytical solutions. Measured parabolic surface deformation showed good agreement with those models. Mirror performance was quantitatively studied using an interferometer and focal lengths from hundreds of meters down to the meter scale have been achieved. In this publication, the deformable mirror has been applied to compensate on shot thermal lensing in 16 mm diameter and 25 mm diameter Nd:Phosphate glass rod amplifiers by using only a single actuator. The possibility to rapidly change focal lengths across two to three orders of magnitude has applications for remote sensing, such as laser induced breakdown spectroscopy, LIDAR, and control of laser filament formation.