Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Science ; 376(6596): 1006-1012, 2022 05 27.
Article in English | MEDLINE | ID: mdl-35617386

ABSTRACT

Temporary postoperative cardiac pacing requires devices with percutaneous leads and external wired power and control systems. This hardware introduces risks for infection, limitations on patient mobility, and requirements for surgical extraction procedures. Bioresorbable pacemakers mitigate some of these disadvantages, but they demand pairing with external, wired systems and secondary mechanisms for control. We present a transient closed-loop system that combines a time-synchronized, wireless network of skin-integrated devices with an advanced bioresorbable pacemaker to control cardiac rhythms, track cardiopulmonary status, provide multihaptic feedback, and enable transient operation with minimal patient burden. The result provides a range of autonomous, rate-adaptive cardiac pacing capabilities, as demonstrated in rat, canine, and human heart studies. This work establishes an engineering framework for closed-loop temporary electrotherapy using wirelessly linked, body-integrated bioelectronic devices.


Subject(s)
Absorbable Implants , Cardiac Pacing, Artificial , Pacemaker, Artificial , Postoperative Care , Wireless Technology , Animals , Dogs , Heart Rate , Humans , Postoperative Care/instrumentation , Rats
2.
JACC Basic Transl Sci ; 6(11): 872-881, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34869951

ABSTRACT

Removal of excess fluid in acute decompensated heart failure (ADHF) targets the intravascular space, whereas most fluid resides in the interstitial space. The authors evaluated an approach to interstitial decongestion using a device to enhance lymph flow. The device was deployed in sheep with induced heart failure (HF) and acute volume overload to create a low-pressure zone at the thoracic duct outlet. Treatment decreased extravascular lung water (EVLW) volume (mL/kg) (-32% ± 9%, P = 0.029) compared to controls (+46% ± 9%, P = 0.003). Device-mediated thoracic duct decompression effectively reduced EVLW. Human studies may establish device-based interstitial decongestion as a new ADHF treatment.

3.
Nat Biotechnol ; 39(10): 1228-1238, 2021 10.
Article in English | MEDLINE | ID: mdl-34183859

ABSTRACT

Temporary cardiac pacemakers used in periods of need during surgical recovery involve percutaneous leads and externalized hardware that carry risks of infection, constrain patient mobility and may damage the heart during lead removal. Here we report a leadless, battery-free, fully implantable cardiac pacemaker for postoperative control of cardiac rate and rhythm that undergoes complete dissolution and clearance by natural biological processes after a defined operating timeframe. We show that these devices provide effective pacing of hearts of various sizes in mouse, rat, rabbit, canine and human cardiac models, with tailored geometries and operation timescales, powered by wireless energy transfer. This approach overcomes key disadvantages of traditional temporary pacing devices and may serve as the basis for the next generation of postoperative temporary pacing technology.


Subject(s)
Absorbable Implants , Pacemaker, Artificial , Animals , Atrioventricular Block/therapy , Disease Models, Animal , Dogs , Equipment Design , Humans , Mice , Rabbits , Rats , Wireless Technology
4.
J Vet Emerg Crit Care (San Antonio) ; 28(5): 436-446, 2018 Sep.
Article in English | MEDLINE | ID: mdl-30117659

ABSTRACT

OBJECTIVE: To evaluate and determine the performance of a partially automated as well as a fully automated closed-loop fluid resuscitation system during states of absolute and relative hypovolemia. DESIGN: Prospective experimental trial. SETTING: Research laboratory. ANIMALS: Five adult Beagle dogs. METHODS: Isoflurane anesthetized mechanically ventilated dogs were subjected to absolute hypovolemia (controlled: 2 trials; uncontrolled: 3 trials), relative hypovolemia (2 trials), and the combination of relative and absolute controlled hypovolemia (2 trials). Controlled and uncontrolled hypovolemia were produced by withdrawing blood from the carotid or femoral artery. Relative hypovolemia was produced by increasing the isoflurane concentration (1 trial) or by infusion of intravenous sodium nitroprusside (1 trial). Relative hypovolemia combined with controlled absolute hypovolemia was produced by increasing the isoflurane concentration (1 trial) and infusion of IV sodium nitroprusside (1 trial). Hemodynamic parameters including stroke volume variation (SVV) were continuously monitored and recorded in all dogs. A proprietary closed-loop fluid administration system based on fluid distribution and compartmental dynamical systems administered a continuous infusion of lactated Ringers solution in order to restore and maintain SVV to a predetermined target value. MEASUREMENTS AND MAIN RESULTS: A total of 9 experiments were performed on 5 dogs. Hemodynamic parameters deteriorated and SVV increased during controlled or uncontrolled hypovolemia, relative hypovolemia, and during relative hypovolemia combined with controlled hypovolemia. Stroke volume variation was restored to baseline values during closed-loop fluid infusion. CONCLUSIONS: Closed-loop fluid administration based on IV fluid distribution and compartmental dynamical systems can be used to provide goal directed fluid therapy during absolute or relative hypovolemia in mechanically ventilated isoflurane anesthetized dogs.


Subject(s)
Dog Diseases/therapy , Fluid Therapy/veterinary , Hypovolemia/veterinary , Animals , Dogs , Female , Hemodynamics , Hypovolemia/therapy , Isoflurane , Male , Monitoring, Physiologic/veterinary , Pilot Projects , Prospective Studies , Random Allocation , Respiration, Artificial/veterinary , Treatment Outcome