Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 140
Filter
1.
Article in English | MEDLINE | ID: mdl-38803006

ABSTRACT

INTRODUCTION: According to current guidelines, pulmonary vein isolation as first-line therapy should be considered for patients with atrial fibrillation (AF), however, optimal timing of the procedure is still unknown in patients with heart failure (HF). We aimed to evaluate the effect of early catheter ablation (CA) in patients with HF and left ventricular ejection fraction (LVEF) below 50%. METHODS: We analyzed data from a structured registry comprising 227 patients with paroxysmal or persistent AF and HF with LVEF < 50% who underwent radiofrequency CA between 2015 and 2022. Early CA was defined as a procedure performed within 12 months of AF diagnosis. The median follow-up duration was 1748 (1176.3-2353.5) days, with a minimum follow-up of 365 days. Our endpoints were AF recurrence after a 3-months blanking period and all-cause mortality. RESULTS: Among the 227 patients with a median age of 64.3 years, 97 (42.7%) experienced AF recurrence and 55 (24.2%) died during the follow-up period. The median LVEF was 40% for early CA and 38% for delayed CA (p = .053). Early CA significantly reduced AF recurrence (HR = 0.25 [0.15-0.42], p < .001), however, the timing of procedure did not affect all-cause mortality (p = .16). These findings were consistent regardless of AF subtype or the burden of comorbidities, as assessed by the CHA2DS2-VASc score. CONCLUSION: The timing of CA of AF appears to be an important factor in patients with HF. Early CA reduced AF recurrence, although it does not impact all-cause mortality. We found similar results regardless of AF subtype or burden of comorbidities.

2.
J Clin Med ; 13(7)2024 Mar 28.
Article in English | MEDLINE | ID: mdl-38610727

ABSTRACT

Background: Atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI) is predominantly attributed to pulmonary vein reconnection (PVR). Predictors of AF recurrence have been widely studied; however, data are scarce on procedural parameters that predict chronic PVR. We aimed to study PVR rates and predictors of PVR. Methods: We retrospectively included 100 patients who underwent repeated ablation due to AF recurrence after initial PVI with the CARTO system. PVR was determined during the repeated procedure by electrophysiological evaluation, and initial procedural characteristics predicting PVR were studied, including adherence to the CLOSE protocol, use of high power, first-pass isolation (FPI), and baseline generator impedance (BGI). Results: Thirty-eight patients underwent initial CLOSE-guided PVI, and sixty-two underwent initial non-CLOSE PVI. A repeat procedure was performed 23 ± 16 months after the initial procedure. In total, PVR was found in 192 of 373 PVs (51.5%), and all PVs were isolated in 17/100 (17%) patients. Factors associated with all PVs being isolated were adherence to the CLOSE protocol, a higher power setting, the presence of bilateral FPI, and lower BGI (88% vs. 28%, p < 0.0001; 37.5 W vs. 30 W, p = 0.0276; 88.2% vs. 40.4%, p = 0.0007; and 127.6 Ω vs. 136.6 Ω, p = 0.0027, respectively). In initial procedures with adherence to the CLOSE protocol, the FPI rate was significantly higher (73.7% vs. 25%, p < 0.0001), while there were no significant differences in terms of procedure time and left atrial dwell time (81 vs. 85 min, p = 0.83; and 60 vs. 58 min, p = 0.08, respectively). BGI ≥ 130 Ω (AUC = 0.7403, sensitivity: 77.1%, specificity: 68.8%, p = 0.0032) was associated with a significantly higher probability of PVR (OR = 6.757; p < 0.0001). In multivariable analysis, independent predictors for PVR were non-adherence to the CLOSE protocol and BGI ≥ 130 Ω. Conclusions: Our findings indicate that adherence to the CLOSE protocol and baseline generator impedance < 130 Ω during AF ablation are independent predictors of PVI durability.

3.
Article in English | MEDLINE | ID: mdl-38551601

ABSTRACT

BACKGROUND: Radiofrequency catheter ablation (RFCA) is a well-established treatment for atrial fibrillation (AF). Fluoroscopy, a widely used imaging method for RFCA, has significant implications for human health. Although no fluoroscopy or near-zero fluoroscopy strategies have gained popularity, they have limitations, such as long procedure times, additional equipment, and expertise. A simple and cost-effective radiation reduction method is needed for treating AF and is compatible with the daily workflow. We aimed to compare the efficacy and safety of fluoroscopy-free and lead apron-free (LAF) after transseptal puncture AF ablation with conventional ablation (CON). METHODS: This retrospective study included all patients who underwent RF catheter AF ablation. The lead apron used for protection was removed immediately before 3D reconstruction of the left atrium (LA) after transseptal puncture (TSP), while fluoroscopy was performed on stand-by and locked-in. The pulmonary vein isolation (PVI) was performed using a 3D mapping system, a multielectrode catheter, and a Smart Touch contact force (CF) sensing catheter, via the lead-apron-free (LAF) method, which is similar to the conventional ablation (CON) method. RESULTS: This study enrolled 152 consecutive patients, with 72 and 80 patients in the LAF and CON groups, respectively. The LAF group demonstrated significantly lower values in total fluoroscopy time (6.9 vs. 14 min, P<0.001) and dose area product (DAP) values (15.4±12.1 vs. 31.5±17.4 G/m2, P<0.001) than the CON group. However, there was no significant difference in the total procedure time (83.6±21.1 vs. 77.2±11.4 min, P=0.12) between the two groups. Only four procedures (5.5%) required repositioning of the apron, and no complications were observed with the LAF method. Pulmonary vein isolation was achieved in all patients. CONCLUSIONS: The LAF method reduced fluoroscopy use compared with CON, with no change in procedure time or efficacy.

4.
Am J Cardiol ; 221: 37-43, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38552710

ABSTRACT

We aimed to correlate left atrial appendage (LAA) structure and function with the history of stroke/transient ischemic attack (TIA) in patients with atrial fibrillation (AF). We analyzed the data of 649 patients with AF who were scheduled for catheter ablation. Patients underwent cardiac computed tomography and transesophageal echocardiography before ablation. The LAA morphologies depicted by cardiac computed tomography were categorized into 4 groups: cauliflower, chicken wing, swan, and windsock shapes. The mean age was 61.3 ± 10.5 years, 33.9% were women. The prevalence of stroke/TIA was 7.1%. After adjustment for the main risk factors, the LAA flow velocity ≤35.3 cm/s (odds ratio [OR] 2.18, 95% confidence interval [CI] 1.09 to 4.61, p = 0.033) and the swan LAA shape (OR 2.69, 95% CI 0.96 to 6.86, p = 0.047) independently associated with a higher risk of stroke/TIA, whereas the windsock LAA morphology proved to be protective (OR 0.32, 95% CI 0.12 to 0.77, p = 0.017) compared with the cauliflower LAA shape. Comparing the differences between the LAA morphology groups, we measured a significantly smaller LAA orifice area (389.3 ± 137.7 mm2 in windsock vs 428.3 ± 158.9 ml in cauliflower, p = 0.021) and LAA volume (7.4 ± 3.0 mm2 in windsock vs 8.5 ± 4.8 mm2 in cauliflower, p = 0.012) in patients with windsock LAA morphology, whereas the LAA flow velocity did not differ significantly. Reduced LAA function and swan LAA morphology were independently associated with a higher prevalence of stroke/TIA, whereas the windsock LAA shape proved to be protective. Comparing the differences between the various LAA morphology types, significantly lower LAA volume and LAA orifice area were measured in the windsock LAA shape than in the cauliflower LAA shape.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Echocardiography, Transesophageal , Ischemic Attack, Transient , Stroke , Humans , Atrial Appendage/diagnostic imaging , Atrial Appendage/physiopathology , Female , Male , Ischemic Attack, Transient/epidemiology , Atrial Fibrillation/physiopathology , Atrial Fibrillation/epidemiology , Middle Aged , Stroke/epidemiology , Stroke/etiology , Risk Factors , Aged , Catheter Ablation , Tomography, X-Ray Computed , Retrospective Studies
5.
Life (Basel) ; 14(1)2024 Jan 17.
Article in English | MEDLINE | ID: mdl-38255747

ABSTRACT

BACKGROUND: Safety, efficacy, and patient comfort are the expectations during pulmonary vein isolation (PVI). We aimed to validate the combined advantages of pre- and periprocedural anticoagulation with non-vitamin K anticoagulants (NOACs) and rigorous left atrial appendage thrombus (LAAT) exclusion with computed tomography (CT). METHODS: This study included a population of consecutive patients, between March 2018 and June 2020, who underwent cardiac CT within 24 h before PVI to guide the ablation and rule out LAAT. NOAC was omitted 24 h before the ablation. RESULTS: A total of 187 patients (63% male) underwent CT before PVI. None of the patients experienced stroke during or after the procedure. The complication rate was low, with no thromboembolic events and 2.1% of patients experiencing a major bleeding event. CONCLUSIONS: Omitting NOAC 24 h before the ablation might be safe if combined with left atrial thrombus exclusion with computed tomography.

6.
Circ Arrhythm Electrophysiol ; 17(2): e012402, 2024 02.
Article in English | MEDLINE | ID: mdl-38284286

ABSTRACT

BACKGROUND: High-power short-duration ablation has shown impressive efficacy and safety for pulmonary vein isolation (PVI); however, initial efficacy results with very high power short-duration ablation were discouraging. This study compared the long-term durability of PVI performed with a 90- versus 50-W power setting. METHODS: Patients were randomized 1:1 to undergo PVI with the QDOT catheter using a power setting of 90 or 50 W. Three months after the index procedure, patients underwent a repeat electrophysiology study to identify pulmonary vein reconnections. Patients were followed for 12 months to detect AF recurrences. RESULTS: We included 46 patients (mean age, 64 years; women, 48%). Procedure (76 versus 84 minutes; P =0.02), left atrial dwell (63 versus 71 minutes; P =0.01), and radiofrequency (303 versus 1040 seconds; P <0.0001) times were shorter with 90- versus 50-W procedures, while the number of radiofrequency applications was higher with 90 versus 50 W (77 versus 67; P =0.01). There was no difference in first-pass isolation (83% versus 82%; P =1.0) or acute reconnection (4% versus 14%; P =0.3) rates between 90 and 50 W. Forty patients underwent a repeat electrophysiology study. Durable PVI on a per PV basis was present in 72/78 (92%) versus 68/77 (88%) PVs in the 90- and 50-W energy setting groups, respectively; effect size: 72/78-68/77=0.040, lower 95% CI=-0.051 (noninferiority limit=-0.1, ie, noninferiority is met). No complications occurred. There was no difference in 12-month atrial fibrillation-free survival between the 90- and 50-W groups (P =0.2). CONCLUSIONS: Similarly high rates of durable PVI and arrhythmia-free survival were achieved with 90 and 50 W. Procedure, left atrial dwell, and radiofrequency times were shorter with 90 W compared with 50 W. The sample size is too small to conclude the safety and long-term efficacy of the high and very high-power short-duration PVI; further studies are needed to address this topic. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT05459831.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Female , Humans , Middle Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Heart Atria/surgery , Pulmonary Veins/surgery , Recurrence , Treatment Outcome , Male , Aged
7.
Geroscience ; 46(2): 2671-2679, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38127223

ABSTRACT

Frailty is a complex clinical syndrome associated with aging and comorbidities, which correlates with unfavorable outcomes. However, in heart failure patients, frailty is very common, data is scarce about those, who are eligible for Cardiac Resynchronization Therapy (CRT) implantation. We investigated the incidence of frailty and the association of Frailty Index (FI) with the outcome. Thirty baseline clinical parameters were used by the Rockwood cumulative deficit method to determine patients' FI in our single-center cohort. Based on previous studies, patients with FI ≤ 0.210 were considered as non-frail, those with FI 0.10-0.210 were classified in Frail-1, with FI > 0.10 in Frail-2 groups, respectively. Echocardiographic response after 12 months and all-cause mortality were investigated by frailty groups. Among 1004 included patients, 75 (7%) were considered Non-frail, 271 (27%) grouped in Frail-1, and 658 (66%) in Frail-2 with a median FI of 0.36 (0.28-0.43). Patients in Frail-2 group were older, with more comorbidities compared with non-frail patients or those in Group Frail-1. During the median follow-up time of 4.8 years, 29 (39%) patients died in the Non-frail, 140 (52%) in Frail-1, and 471 (72%) in the Frail-2 groups (log-rank p < 0.001). Group Frail-2 showed an unfavorable outcome compared to the non-frail (HR 2.49, 95%CI 1.92-3.22; p < 0.001) and the Frail-1 group (1.83, 95%CI 1.55-2.16; p < 0.001). In our HFrEF patients eligible for CRT implantation, patients were exceedingly vulnerable with a high prevalence of frailty. The calculated frailty index was associated with outcome and proved to be prevalent in individual risk stratification.


Subject(s)
Cardiac Resynchronization Therapy , Frailty , Heart Failure , Humans , Frailty/epidemiology , Heart Failure/epidemiology , Heart Failure/therapy , Prevalence , Stroke Volume
8.
Bioengineering (Basel) ; 10(12)2023 Dec 01.
Article in English | MEDLINE | ID: mdl-38135977

ABSTRACT

BACKGROUND: Ventricular tachycardia (VT) recurrence after catheter ablation remains a concern, emphasizing the need for precise risk assessment. We aimed to use machine learning (ML) to predict 1-month and 1-year VT recurrence following VT ablation. METHODS: For 337 patients undergoing VT ablation, we collected 31 parameters including medical history, echocardiography, and procedural data. 17 relevant features were included in the ML-based feature selection, which yielded six and five optimal features for 1-month and 1-year recurrence, respectively. We trained several supervised machine learning models using 10-fold cross-validation for each endpoint. RESULTS: We observed 1-month VT recurrence was observed in 60 (18%) cases and accurately predicted using our model with an area under the receiver operating curve (AUC) of 0.73. Input features used were hemodynamic instability, incessant VT, ICD shock, left ventricular ejection fraction, TAPSE, and non-inducibility of the clinical VT at the end of the procedure. A separate model was trained for 1-year VT recurrence (observed in 117 (35%) cases) with a mean AUC of 0.71. Selected features were hemodynamic instability, the number of inducible VT morphologies, left ventricular systolic diameter, mitral regurgitation, and ICD shock. For both endpoints, a random forest model displayed the highest performance. CONCLUSIONS: Our ML models effectively predict VT recurrence post-ablation, aiding in identifying high-risk patients and tailoring follow-up strategies.

9.
Europace ; 25(11)2023 11 02.
Article in English | MEDLINE | ID: mdl-37931067

ABSTRACT

AIMS: Cerebral thrombo-embolism is a dreaded complication of pulmonary vein isolation (PVI) for atrial fibrillation; its surrogate, silent cerebral embolism (SCE) can be detected by diffusion-weighted brain magnetic resonance imaging (bMRI). Initial investigations have raised a concern that very high-power, short-duration (vHPSD; 90 W/4 s) temperature-controlled PVI with the QDOT Micro catheter may be associated with a higher incidence of SCE compared with low-power long-duration ablation. We aimed to assess the incidence of procedural complications of vHPSD PVI with an emphasis on cerebral safety. METHODS AND RESULTS: We enrolled 328 consecutive patients undergoing their PVI procedure using vHPSD. A subgroup of 61 consecutive patients underwent diffusion-weighted bMRI within 24 h of the procedure, and incidence and predictors of SCE were studied. The mean procedure time and left atrial dwell time for the overall cohort were 69.6 ± 24.1 and 46.5 ± 21.5 min, respectively. First-pass isolation was achieved in 82%. No stroke or transient ischaemic attack occurred. Silent cerebral embolism was identified in 5 of 61 patients (8.2%). Silent cerebral embolism following procedures was significantly associated with lower baseline generator impedance (105.8 vs. 112.6 Ω, P < 0.0001) and with intermittent loss of catheter-tissue contact during ablation (14.1% vs. 6.1%, P < 0.0001). CONCLUSION: Very high-power, short-duration PVI is a safe technique with an excellent acute success rate. Silent cerebral embolism incidence in our cohort was below the previously reported range, with no clinically overt cerebral complications. Lower baseline generator impedance and loss of contact during ablation may contribute to a higher risk of SCEs.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Intracranial Embolism , Pulmonary Veins , Stroke , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Intracranial Embolism/diagnostic imaging , Intracranial Embolism/epidemiology , Incidence , Heart Atria , Stroke/diagnosis , Stroke/epidemiology , Stroke/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Pulmonary Veins/surgery , Treatment Outcome
10.
Sci Rep ; 13(1): 20594, 2023 11 23.
Article in English | MEDLINE | ID: mdl-37996448

ABSTRACT

Choosing the optimal device during cardiac resynchronization therapy (CRT) upgrade can be challenging. Therefore, we sought to provide a solution for identifying patients in whom upgrading to a CRT-defibrillator (CRT-D) is associated with better long-term survival than upgrading to a CRT-pacemaker (CRT-P). To this end, we first applied topological data analysis to create a patient similarity network using 16 clinical features of 326 patients without prior ventricular arrhythmias who underwent CRT upgrade. Then, in the generated circular network, we delineated three phenogroups exhibiting significant differences in clinical characteristics and risk of all-cause mortality. Importantly, only in the high-risk phenogroup was upgrading to a CRT-D associated with better survival than upgrading to a CRT-P (hazard ratio: 0.454 (0.228-0.907), p = 0.025). Finally, we assigned each patient to one of the three phenogroups based on their location in the network and used this labeled data to train multi-class classifiers to enable the risk stratification of new patients. During internal validation, an ensemble of 5 multi-layer perceptrons exhibited the best performance with a balanced accuracy of 0.898 (0.854-0.942) and a micro-averaged area under the receiver operating characteristic curve of 0.983 (0.980-0.986). To allow further validation, we made the proposed model publicly available ( https://github.com/tokmarton/crt-upgrade-risk-stratification ).


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Pacemaker, Artificial , Humans , Cardiac Resynchronization Therapy/adverse effects , Arrhythmias, Cardiac/etiology , Risk Assessment , Treatment Outcome
11.
Front Cardiovasc Med ; 10: 1185187, 2023.
Article in English | MEDLINE | ID: mdl-37560116

ABSTRACT

Purpose: Our purpose was to compare the procedural characteristics, success rate, and complication rate of the conventional fluoroscopic (CF) and the zero-fluoroscopic (ZF) approach in patients undergoing catheter ablation of AVNRT or typical atrial flutter (Aflu). Methods: 186 consecutive patients with an indication for AVNRT or Aflu ablation were enrolled. Based on the operator's preference, the patients were assigned to either CF or ZF group. In the ZF group EnSite NavX, Carto3, or Rhythmia EAMS were used for catheter guidance. Results: The median age was 56 (IQR = 42-68) years, 144 patients had AVNRT, and 42 had Aflu ablation. CF approach was chosen in 123 cases, while ZF in 63 cases. ZF approach was used more often in case of AVNRT patients [56 (39%) vs. 7 (17%), p = 0.006] and in the case of female patients [43 (68%) vs. 20 (32%), p = 0.008]. Acute procedural success was obtained in all cases. There was no difference in the complication rate (1 vs. 1, p > 0.99) between the two groups. No difference was found regarding the procedure time between the CF and ZF groups [CF: 55 (46-60) min, ZF 60 (47-65) min; p = 0.487] or in the procedure time for the different EAMS [EnSite NavX: 58 (50-63) min, Carto3: 60 (44.5-66.3) min, Rhythmia: 55 (35-69) min; p = 0.887]. A similar success rate was seen at the 3-month follow-up in the two groups [41 (100%) vs. 96 (97%); p = 0.55]. Discussion: The ZF approach demonstrated non-inferiority in safety and efficacy compared with CF for the AVNRT and Aflu ablations.

12.
J Arrhythm ; 39(4): 539-545, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37560278

ABSTRACT

Background: The efficiency of pulmonary vein isolation (PVI) depends on the durability of RF lesions. Recent studies documented sustained continuity of ablation lines, improvements in durability, and expected clinical outcomes through altered settings in duration and power. However, the ablation strategy has not been adapted to this new approach and different biophysics of lesion formation. Purpose: The aim of this study was to demonstrate that by adjusting the ablation approach to the broader geometry of lesions by increasing the minimal spacing between adjacent RF, a further significant reduction of procedural time while maintaining sufficient long-term outcomes is achievable. Methods: The presented study was a prospective, observational multi-center trial. The periprocedural data were compared with data from a consecutively collected historical cohort. Results: In total, 196 patients were included (mean age 62 ± 11 years, male 64.3%). Procedural duration, RF time, and LA dwelling time were significantly shorter in the HPSD group compared with the standard group (73 ± 26 min vs. 98 ± 36 min, p < .001; 14 ± 7 min vs. 33 ± 12 min, p < .001; and 59 ± 21 min vs. 77 ± 32 min, p < .001, respectively). Mean AF-free survival in the first year of follow-up was 304 ± 14 days in the HPSD group versus 340 ± 10 days in the standard group (log-rank p = .403). There were no statistically significant differences in the complication rates between the groups. Conclusion: Increasing the minimal distance between individual application points simplifies AF ablation and further reduces procedure time without negative effects on efficacy and safety. Larger studies are needed to optimally utilize this approach.

13.
Clin Res Cardiol ; 2023 Aug 25.
Article in English | MEDLINE | ID: mdl-37624394

ABSTRACT

BACKGROUND: Current guidelines recommend considering multiple factors while deciding between cardiac resynchronization therapy with a defibrillator (CRT-D) or a pacemaker (CRT-P). Nevertheless, it is still challenging to pinpoint those candidates who will benefit from choosing a CRT-D device in terms of survival. OBJECTIVE: We aimed to use topological data analysis (TDA) to identify phenogroups of CRT patients in whom CRT-D is associated with better survival than CRT-P. METHODS: We included 2603 patients who underwent CRT-D (54%) or CRT-P (46%) implantation at Semmelweis University between 2000 and 2018. The primary endpoint was all-cause mortality. We applied TDA to create a patient similarity network using 25 clinical features. Then, we identified multiple phenogroups in the generated network and compared the groups' clinical characteristics and survival. RESULTS: Five- and 10-year mortality were 43 (40-46)% and 71 (67-74)% in patients with CRT-D and 48 (45-50)% and 71 (68-74)% in those with CRT-P, respectively. TDA created a circular network in which we could delineate five phenogroups showing distinct patterns of clinical characteristics and outcomes. Three phenogroups (1, 2, and 3) included almost exclusively patients with non-ischemic etiology, whereas the other two phenogroups (4 and 5) predominantly comprised ischemic patients. Interestingly, only in phenogroups 2 and 5 were CRT-D associated with better survival than CRT-P (adjusted hazard ratio 0.61 [0.47-0.80], p < 0.001 and adjusted hazard ratio 0.84 [0.71-0.99], p = 0.033, respectively). CONCLUSIONS: By simultaneously evaluating various clinical features, TDA may identify patients with either ischemic or non-ischemic etiology who will most likely benefit from the implantation of a CRT-D instead of a CRT-P. Topological data analysis to identify phenogroups of CRT patients in whom CRT-D is associated with better survival than CRT-P. AF atrial fibrillation, CRT cardiac resynchronization therapy, CRT-D cardiac resynchronization therapy defibrillator, CRT-P cardiac resynchronization therapy pacemaker, DM diabetes mellitus, HTN hypertension, LBBB left bundle branch block, LVEF left ventricular ejection fraction, MDS multidimensional scaling, MRA mineralocorticoid receptor antagonist, NYHA New York Heart Association.

14.
Eur Heart J ; 44(40): 4259-4269, 2023 Oct 21.
Article in English | MEDLINE | ID: mdl-37632437

ABSTRACT

BACKGROUND AND AIMS: De novo implanted cardiac resynchronization therapy with defibrillator (CRT-D) reduces the risk of morbidity and mortality in patients with left bundle branch block, heart failure and reduced ejection fraction (HFrEF). However, among HFrEF patients with right ventricular pacing (RVP), the efficacy of CRT-D upgrade is uncertain. METHODS: In this multicentre, randomized, controlled trial, 360 symptomatic (New York Heart Association Classes II-IVa) HFrEF patients with a pacemaker or implantable cardioverter defibrillator (ICD), high RVP burden ≥ 20%, and a wide paced QRS complex duration ≥ 150 ms were randomly assigned to receive CRT-D upgrade (n = 215) or ICD (n = 145) in a 3:2 ratio. The primary outcome was the composite of all-cause mortality, heart failure hospitalization, or <15% reduction of left ventricular end-systolic volume assessed at 12 months. Secondary outcomes included all-cause mortality or heart failure hospitalization. RESULTS: Over a median follow-up of 12.4 months, the primary outcome occurred in 58/179 (32.4%) in the CRT-D arm vs. 101/128 (78.9%) in the ICD arm (odds ratio 0.11; 95% confidence interval 0.06-0.19; P < .001). All-cause mortality or heart failure hospitalization occurred in 22/215 (10%) in the CRT-D arm vs. 46/145 (32%) in the ICD arm (hazard ratio 0.27; 95% confidence interval 0.16-0.47; P < .001). The incidence of procedure- or device-related complications was similar between the two arms [CRT-D group 25/211 (12.3%) vs. ICD group 11/142 (7.8%)]. CONCLUSIONS: In pacemaker or ICD patients with significant RVP burden and reduced ejection fraction, upgrade to CRT-D compared with ICD therapy reduced the combined risk of all-cause mortality, heart failure hospitalization, or absence of reverse remodelling.

15.
Front Cardiovasc Med ; 10: 1177347, 2023.
Article in English | MEDLINE | ID: mdl-37396587

ABSTRACT

Introduction: Left atrial appendage (LAA) thrombus is the most common source of embolization in atrial fibrillation (AF). Transesophageal echocardiography (TEE) is the gold standard method for LAA thrombus exclusion. Our pilot study aimed to compare the efficacy of a new non-contrast-enhanced cardiac magnetic resonance (CMR) sequence (BOOST) with TEE for the detection of LAA thrombus and to evaluate the usefulness of BOOST images for planning radiofrequency catheter ablation (RFCA) compared with left atrial (LA) contrast-enhanced computed tomography (CT). We also attempted to assess the patients' subjective experiences with TEE and CMR. Methods: Patients with AF undergoing either electrical cardioversion or RFCA were enrolled. Participants underwent pre-procedural TEE and CMR scans to evaluate LAA thrombus status and pulmonary vein anatomy. Patient experiences with TEE and CMR were assessed using a questionnaire developed by our team. Some patients scheduled for RFCA also had pre-procedural LA contrast-enhanced CT. In such cases, the operating physician was asked to subjectively define the quality of the CT and CMR scan on a scale of 1-10 (1 = worst, 10 = best) and comment on CMR's usefulness in RFCA planning. Results: Seventy-one patients were enrolled. In 94.4%, both TEE and CMR excluded, and in 1 patient, both modalities reported the presence of LAA thrombus. In 1 patient, TEE was inconclusive, but CMR excluded LAA thrombus. In 2 patients, CMR could not exclude the presence of thrombus, but in 1 of those cases, TEE was also indecisive. During TEE, 67%, during CMR, only 1.9% of patients reported pain (p < 0.0001), and 89% would prefer CMR in case of a repeat examination. The quality of the left atrial contrast-enhanced CT scans was better compared with the image quality of the CMR BOOST sequence [8 (7-9) vs. 6 (5-7), p < 0.0001]. Still, the CMR images were useful for procedural planning in 91% of cases. Conclusion: The new CMR BOOST sequence provides appropriate image quality for ablation planning. The sequence might be useful for excluding larger LAA thrombi; however, its accuracy in detecting smaller thrombi is limited. Most patients preferred CMR over TEE in this indication.

17.
J Cardiovasc Dev Dis ; 10(5)2023 May 14.
Article in English | MEDLINE | ID: mdl-37233181

ABSTRACT

Remote monitoring (RM) is the newest function of cardiac implantable electronic devices (CIEDs). In our observational retrospective analysis, we aimed to assess whether telecardiology could be a safe alternative to routine outpatient examinations during the COVID-19 pandemic. The in- and outpatient visits, the number of acute cardiac decompensation episodes, the RM data from CIEDs, and general condition were examined via questionnaires (KCCQ, EQ-5D-5L). Regarding the enrolled 85 patients, the number of personal patient appearances was significantly lower in the year following the pandemic outbreak compared to the previous year (1.4 ± 1.4 and 1.9 ± 1.2, p = 0.0077). The number of acute decompensation events was five before and seven during lockdown (p = 0.6). Based on the RM data, there was no significant difference in heart failure (HF) markers (all related p > 0.05); only patient activity increased after restrictions were lifted compared to that before the lockdown (p = 0.03). During restrictions, patients reported increased anxiety and depression compared to their previous state (p < 0.001). There was no subjective change in the perception of HF symptoms (p = 0.7). Based on the subjective perception and CIED data, the quality of life of patients with CIED did not deteriorate during the pandemic, but their anxiety and depression intensified. Telecardiology may be a safe alternative to routine inpatient examination.

18.
Europace ; 25(5)2023 05 19.
Article in English | MEDLINE | ID: mdl-36916199

ABSTRACT

AIMS: The field of conduction system pacing (CSP) is evolving, and our aim was to obtain a contemporary picture of European CSP practice. METHODS AND RESULTS: A survey was devised by a European CSP Expert Group and sent electronically to cardiologists utilizing CSP. A total of 284 physicians were invited to contribute of which 171 physicians (60.2%; 85% electrophysiologists) responded. Most (77%) had experience with both His-bundle pacing (HBP) and left bundle branch area pacing (LBBAP). Pacing indications ranked highest for CSP were atrioventricular block (irrespective of left ventricular ejection fraction) and when coronary sinus lead implantation failed. For patients with left bundle branch block (LBBB) and heart failure (HF), conventional biventricular pacing remained first-line treatment. For most indications, operators preferred LBBAP over HBP as a first-line approach. When HBP was attempted as an initial approach, reasons reported for transitioning to utilizing LBBAP were: (i) high threshold (reported as >2 V at 1 ms), (ii) failure to reverse bundle branch block, or (iii) > 30 min attempting to implant at His-bundle sites. Backup right ventricular lead use for HBP was low (median 20%) and predominated in pace-and-ablate scenarios. Twelve-lead electrocardiogram assessment was deemed highly important during follow-up. This, coupled with limitations from current capture management algorithms, limits remote monitoring for CSP patients. CONCLUSIONS: This survey provides a snapshot of CSP implementation in Europe. Currently, CSP is predominantly used for bradycardia indications. For HF patients with LBBB, most operators reserve CSP for biventricular implant failures. Left bundle branch area pacing ostensibly has practical advantages over HBP and is therefore preferred by many operators. Practical limitations remain, and large randomized clinical trial data are currently lacking.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Humans , Stroke Volume/physiology , Ventricular Function, Left , Treatment Outcome , Heart Conduction System , Bundle-Branch Block/diagnosis , Bundle-Branch Block/therapy , Arrhythmias, Cardiac/therapy , Heart Failure/diagnosis , Heart Failure/therapy
19.
Geroscience ; 45(4): 2289-2301, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36800059

ABSTRACT

Heart failure (HF) is a leading cause of mortality and hospitalization in the elderly. However, data are scarce about their response to device treatment such as cardiac resynchronization therapy (CRT). We aimed to evaluate the age-related differences in the effectiveness of CRT, procedure-related complications, and long-term outcome. Between 2000 and 2020, 2656 patients undergoing CRT implantation were registered and analyzed retrospectively. Patients were divided into 3 groups according to their age: group I, < 65; group II, 65-75; and group III, > 75 years. The primary endpoint was the echocardiographic response defined as a relative increase > 15% in left ventricular ejection fraction (LVEF) within 6 months, and the secondary endpoint was the composite of all-cause mortality, heart transplantation, or left ventricular assist device implantation. Procedure-related complications were also assessed. After implantation, LVEF showed significant improvement both in the total cohort [28% (IQR 24/33) vs. 35% (IQR 28/40); p < 0.01)] and in each subgroup (27% vs. 34%; p < 0.01, 29% vs. 35%; p < 0.01, 30% vs. 35%; p < 0.01). Response rate was similar in the 3 groups (64% vs. 62% vs. 56%; p = 0.41). During the follow-up, 1574 (59%) patients died. Kaplan-Meier curves revealed a significantly lower survival rate in the older groups (log-rank p < 0.001). The cumulative complication rates were similar among the three age groups (27% vs. 28% vs. 24%; p = 0.15). Our results demonstrate that CRT is as effective and safe therapy in the elderly as for young ones. The present data suggest that patients with appropriate indications benefit from CRT in the long term, regardless of age.


Subject(s)
Cardiac Resynchronization Therapy , Ventricular Function, Left , Humans , Aged , Stroke Volume/physiology , Ventricular Function, Left/physiology , Cardiac Resynchronization Therapy/methods , Treatment Outcome , Retrospective Studies
20.
Coron Artery Dis ; 34(1): 18-23, 2023 01 01.
Article in English | MEDLINE | ID: mdl-36484216

ABSTRACT

BACKGROUND: Cardiac computed tomography (CT) is often performed before catheter ablation of atrial fibrillation to map atrial and pulmonary anatomy. Incident coronary artery disease (CAD) may also be diagnosed during cardiac CT angiography (CTA). Our aim was to assess whether coronary CTA might be able to identify a significant proportion of patients with obstructive CAD prior to their catheter ablation procedure event, even in asymptomatic patients. METHODS: Consecutive patients undergoing pre-ablation coronary CTA for atrial fibrillation between 2013 and 2020 were retrospectively selected. Patients with previously diagnosed CAD were excluded. Obstructive CAD was defined as ≥50% luminal stenosis. We analyzed the relationship between obstructive CAD, any chest pain, and traditional risk factors. RESULTS: Overall, 2321 patients [median age 63.0 (54.4-69.2), 1052/2321 (45.3%) female] underwent coronary CTA and 488/2321 (21.0%) were diagnosed with obstructive CAD. There was no difference regarding the rate of obstructive CAD in patients with any chest pain compared to patients without any chest pain [91/404 (22.5%) vs. 397/1917 (20.7%), P = 0.416, respectively). The following parameters were associated with obstructive CAD: age > 65 years [odds ratio (OR) = 2.51; 95% confidence interval (CI), 2.02-3.13; P < 0.001), male sex (OR = 1.59; 95% CI, 1.28-1.98; P < 0.001), hypertension (OR = 1.40; 95% CI, 1.08-1.81; P = 0.012), diabetes (OR = 1.50; 95% CI, 1.13-1.99; P = 0.006), dyslipidaemia (OR = 1.33; 95% CI, 1.07-1.66; P = 0.011) and history of smoking (OR = 1.34; 95% CI, 1.07-1.68; P = 0.011). CONCLUSIONS: The high prevalence of obstructive CAD even in patients without chest pain highlights the importance of additional coronary artery diagnostics in patients undergoing left atrial CTA awaiting catheter ablation for atrial fibrillation. These patients regardless of chest pain thus may require further risk modification to decrease their potential ischemic and thromboembolic risk.


Subject(s)
Atrial Fibrillation , Coronary Artery Disease , Humans , Female , Male , Middle Aged , Aged , Computed Tomography Angiography , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/epidemiology , Coronary Artery Disease/surgery , Retrospective Studies , Chest Pain
SELECTION OF CITATIONS
SEARCH DETAIL
...