1.
Chirurg ; 82(10): 913-20, 2011 Oct.
Article in German | MEDLINE | ID: mdl-21455808

ABSTRACT

BACKGROUND: Postoperative recurrent laryngeal nerve (RLN) palsy is a well-known and dreaded complication of thyroid surgery. Continuous intraoperative neuromonitoring (CIONM) has been developed in order to provide an effective real-time surveillance of the RLN to its full extent and to detect subtle changes in nerve conductivity. A key requirement for a reliable interpretation of CIONM is signal stability. PATIENTS AND METHODS: In a prospective randomized controlled pilot study 24 patients corresponding to 30 nerves at risk (NaR) were included to compare a newly developed, flexible, saxophone-shaped backstrap electrode for vagal stimulation (16 NaR) to a commercially available CE-marked cylindrical and rigid electrode (14 NaR). Electrode applicability, safety and signal stability were analyzed by assessment of electrode implantation times, stimulation currents, EMG amplitudes and electrode displacement rates. RESULTS: Implantation and extraction was significantly faster and easier with the saxophone-shaped backstrap electrode. Accidental electrode displacement occurred up to eight times per operation when applying the cylindrical electrode, while a total of two displacements resulted using the backstrap electrode in this study. Stimulation currents necessary for supramaximal RLN stimulation were significantly lower using the newly developed electrode. At the same time, significantly greater stable EMG amplitudes resulted using the new saxophone-shaped electrode. No RLN palsy occurred during the study. CONCLUSIONS: According to the data, only the saxophone-shaped backstrap electrode provided the signal stability required for CIONM. The closed electrode geometry with isolated contacts for nerve stimulation and defined current entry provide the prerequisites required for reliable continuous intraoperative neuromonitoring.


Subject(s)
Electrodes, Implanted , Electromyography/instrumentation , Monitoring, Intraoperative/instrumentation , Parathyroidectomy , Postoperative Complications/prevention & control , Postoperative Complications/physiopathology , Signal Processing, Computer-Assisted/instrumentation , Thyroidectomy , Vagus Nerve Stimulation/instrumentation , Vocal Cord Paralysis/prevention & control , Vocal Cord Paralysis/physiopathology , Adult , Aged , Aged, 80 and over , Child , Equipment Design , Female , Humans , Infant , Male , Middle Aged , Pilot Projects , Prospective Studies , Vocal Cord Paralysis/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL
...