1.
Europace ; 25(6)2023 06 02.
Article in English | MEDLINE | ID: mdl-37314196

ABSTRACT

AIMS: The standard implantable cardioverter defibrillator (ICD) generator (can) is placed in the left pectoral area; however, in certain circumstances, right-sided cans may be required which may increase defibrillation threshold (DFT) due to suboptimal shock vectors. We aim to quantitatively assess whether the potential increase in DFT of right-sided can configurations may be mitigated by alternate positioning of the right ventricular (RV) shocking coil or adding coils in the superior vena cava (SVC) and coronary sinus (CS). METHODS AND RESULTS: A cohort of CT-derived torso models was used to assess DFT of ICD configurations with right-sided cans and alternate positioning of RV shock coils. Efficacy changes with additional coils in the SVC and CS were evaluated. A right-sided can with an apical RV shock coil significantly increased DFT compared to a left-sided can [19.5 (16.4, 27.1) J vs. 13.3 (11.7, 19.9) J, P < 0.001]. Septal positioning of the RV coil led to a further DFT increase when using a right-sided can [26.7 (18.1, 36.1) J vs. 19.5 (16.4, 27.1) J, P < 0.001], but not a left-sided can [12.1 (8.1, 17.6) J vs. 13.3 (11.7, 19.9) J, P = 0.099). Defibrillation threshold of a right-sided can with apical or septal coil was reduced the most by adding both SVC and CS coils [19.5 (16.4, 27.1) J vs. 6.6 (3.9, 9.9) J, P < 0.001, and 26.7 (18.1, 36.1) J vs. 12.1 (5.7, 13.5) J, P < 0.001]. CONCLUSION: Right-sided, compared to left-sided, can positioning results in a 50% increase in DFT. For right-sided cans, apical shock coil positioning produces a lower DFT than septal positions. Elevated right-sided can DFTs may be mitigated by utilizing additional coils in SVC and CS.


Subject(s)
Coronary Sinus , Defibrillators, Implantable , Humans , Vena Cava, Superior/diagnostic imaging , Computer Simulation , Heart Ventricles
2.
Heart Rhythm O2 ; 3(2): 186-195, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35496454

ABSTRACT

Background: The effect of chronic ischemic scar on repolarization is unclear, with conflicting results from human and animal studies. An improved understanding of electrical remodeling within scar and border zone tissue may enhance substrate-guided ablation techniques for treatment of ventricular tachycardia. Computational modeling studies have suggested increased dispersion of repolarization during epicardial, but not endocardial, left ventricular pacing, in close proximity to scar. However, the effect of endocardial pacing near scar in vivo is unknown. Objective: The purpose of this study was to investigate the effect of scar and pacing location on local repolarization in a porcine myocardial infarction model. Methods: Six model pigs underwent late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) imaging followed by electroanatomic mapping of the left ventricular endocardium. LGE-CMR images were registered to the anatomic shell and scar defined by LGE. Activation recovery intervals (ARIs), a surrogate for action potential duration, and local ARI gradients were calculated from unipolar electrograms within areas of late gadolinium enhancement (aLGE) and healthy myocardium. Results: There was no significant difference between aLGE and healthy myocardium in mean ARI (304.20 ± 19.44 ms vs 300.59 ± 19.22 ms; P = .43), ARI heterogeneity (23.32 ± 11.43 ms vs 24.85 ± 12.99 ms; P = .54), or ARI gradients (6.18 ± 2.09 vs 5.66 ± 2.32 ms/mm; P = .39). Endocardial pacing distance from scar did not affect ARI gradients. Conclusion: Our findings suggest that changes in ARI are not an intrinsic property of surviving myocytes within scar, and endocardial pacing close to scar does not affect local repolarization.

3.
Comput Biol Med ; 141: 105061, 2022 02.
Article in English | MEDLINE | ID: mdl-34915331

ABSTRACT

BACKGROUND: Computational models of the heart built from cardiac MRI and electrophysiology (EP) data have shown promise for predicting the risk of and ablation targets for myocardial infarction (MI) related ventricular tachycardia (VT), as well as to predict paced activation sequences in heart failure patients. However, most recent studies have relied on low resolution imaging data and little or no EP personalisation, which may affect the accuracy of model-based predictions. OBJECTIVE: To investigate the impact of model anatomy, MI scar morphology, and EP personalisation strategies on paced activation sequences and VT inducibility to determine the level of detail required to make accurate model-based predictions. METHODS: Imaging and EP data were acquired from a cohort of six pigs with experimentally induced MI. Computational models of ventricular anatomy, incorporating MI scar, were constructed including bi-ventricular or left ventricular (LV) only anatomy, and MI scar morphology with varying detail. Tissue conductivities and action potential duration (APD) were fitted to 12-lead ECG data using the QRS duration and the QT interval, respectively, in addition to corresponding literature parameters. Paced activation sequences and VT induction were simulated. Simulated paced activation and VT inducibility were compared between models and against experimental data. RESULTS: Simulations predict that the level of model anatomical detail has little effect on simulated paced activation, with all model predictions comparing closely with invasive EP measurements. However, detailed scar morphology from high-resolution images, bi-ventricular anatomy, and personalized tissue conductivities are required to predict experimental VT outcome. CONCLUSION: This study provides clear guidance for model generation based on clinical data. While a representing high level of anatomical and scar detail will require high-resolution image acquisition, EP personalisation based on 12-lead ECG can be readily incorporated into modelling pipelines, as such data is widely available.


Subject(s)
Myocardial Infarction , Tachycardia, Ventricular , Animals , Electrocardiography , Heart , Heart Ventricles/diagnostic imaging , Humans , Myocardial Infarction/diagnostic imaging , Swine , Tachycardia, Ventricular/diagnostic imaging
4.
Comput Biol Med ; 123: 103895, 2020 08.
Article in English | MEDLINE | ID: mdl-32741753

ABSTRACT

Patients with scar-associated fibrotic tissue remodelling are at greater risk of ventricular arrhythmic events, but current methods to detect the presence of such remodelling require invasive procedures. We present here a potential method to detect the presence, location and dimensions of scar using pacing-dependent changes in the vectorcardiogram (VCG). Using a clinically-derived whole-torso computational model, simulations were conducted at both slow and rapid pacing for a variety of scar patterns within the myocardium, with various VCG-derived metrics being calculated, with changes in these metrics being assessed for their ability to discern the presence and size of scar. Our results indicate that differences in the dipole angle at the end of the QRS complex and differences in the QRS area and duration may be used to predict scar properties. Using machine learning techniques, we were also able to predict the location of the scar to high accuracy, using only these VCG-derived rate-dependent changes as input. Such a non-invasive predictive tool for the presence of scar represents a potentially useful clinical tool for identifying patients at arrhythmic risk.


Subject(s)
Cardiomyopathy, Dilated , Cardiomyopathy, Dilated/diagnostic imaging , Cicatrix , Electrocardiography , Fibrosis , Heart Ventricles , Humans , Myocardium
5.
Comput Biol Med ; 112: 103368, 2019 09.
Article in English | MEDLINE | ID: mdl-31352217

ABSTRACT

Implanted cardiac defibrillators (ICDs) seek to automatically detect and terminate potentially lethal ventricular arrhythmias by applying strong internal electric shocks across the heart. However, the optimisation of the specific electrode design and configurations represents an intensive area of research in the pursuit of reduced shock strengths and fewer device complications and risks. Computational whole-torso simulations play an important role in this endeavour, although knowing which specific metric should be used to assess configuration efficacy and assessing the impact of different patient anatomies and pathologies, and the corresponding effect this may have on different metrics has not been investigated. We constructed a cohort of CT-derived high-resolution whole torso-cardiac computational models, including variants of cardiomyopathies and patients with differing torso dimensions. Simulations of electric shock application between electrode configurations corresponding to transveneous (TV-ICD) and subcutaneous (S-ICD) ICDs were modelled and conventional metrics such as defibrillation threshold (DFT) and impedance computed. In addition, we computed a novel metric termed the shock vector efficiency (η), which quantifies the fraction of electrical energy dissipated in the heart relative to the rest of the torso. Across the cohort, S-ICD configurations showed higher DFTs and impedances than TV-ICDs, as expected, although little consistent difference was seen between healthy and cardiomyopathy variants. η was consistently <2% for S-ICD configurations, becoming as high as 13% for TV-ICD setups. Simulations also suggested that a total torso height of approximately 20 cm is required for convergence in η. Overall, η was seen to be approximately negatively correlated with both DFT and impedance. However, important scenarios were identified in which certain values of DFT (or impedance) were associated with a range of η values, and vice-versa, highlighting the heterogeneity introduced by the different torsos and pathologies modelled. In conclusion, the shock vector efficiency represents a useful additional metric to be considered alongside DFT and impedance in the optimisation of ICD electrode configurations, particularly in the context of differing torso anatomies and cardiac pathologies, which can induce significant heterogeneity in conventional metrics of ICD efficacy.


Subject(s)
Arrhythmias, Cardiac , Computer Simulation , Defibrillators, Implantable , Models, Cardiovascular , Tomography, X-Ray Computed , Adult , Aged, 80 and over , Arrhythmias, Cardiac/diagnostic imaging , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/therapy , Female , Humans , Male , Middle Aged
6.
Prog Biophys Mol Biol ; 129: 20-24, 2017 10.
Article in English | MEDLINE | ID: mdl-28341288

ABSTRACT

As computational biology matures as a field, increasing attention is being paid to the relation of computational models to their target. One aspect of this is addressing how computational models can appropriately reproduce the variation seen in experimental data, with one solution being to use populations of models united by a common set of equations (the framework), with each individual member of the population (each model) possessing its own unique set of equation parameters. These model populations are then calibrated and validated against experimental data, and as a whole reproduce the experimentally observed variation. The primary focus of validation thus becomes the population, with the individual models' validation seemingly deriving from their membership of this population. The role of individual models within the population is not clear, with uncertainty regarding the relationship between individual models and the population they make up. This work examines the role of models within the population, how they relate to the population they make up, and how both can be said to be validated in this context.


Subject(s)
Computational Biology/methods , Models, Biological
7.
Prog Biophys Mol Biol ; 121(2): 169-84, 2016 07.
Article in English | MEDLINE | ID: mdl-27320382

ABSTRACT

Computational modelling, combined with experimental investigations, is a powerful method for investigating complex cardiac electrophysiological behaviour. The use of rabbit-specific models, due to the similarities of cardiac electrophysiology in this species with human, is especially prevalent. In this paper, we first briefly review rabbit-specific computational modelling of ventricular cell electrophysiology, multi-cellular simulations including cellular heterogeneity, and acute ischemia. This mini-review is followed by an original computational investigation of variability in the electrophysiological response of two experimentally-calibrated populations of rabbit-specific ventricular myocyte action potential models to acute ischemia. We performed a systematic exploration of the response of the model populations to varying degrees of ischemia and individual ischemic parameters, to investigate their individual and combined effects on action potential duration and refractoriness. This revealed complex interactions between model population variability and ischemic factors, which combined to enhance variability during ischemia. This represents an important step towards an improved understanding of the role that physiological variability may play in electrophysiological alterations during acute ischemia.


Subject(s)
Electrophysiological Phenomena , Heart Ventricles/pathology , Models, Cardiovascular , Myocardial Ischemia/pathology , Myocardial Ischemia/physiopathology , Action Potentials , Acute Disease , Adenosine Triphosphate/metabolism , Animals , Humans , Potassium/metabolism , Rabbits , Species Specificity
8.
Prog Biophys Mol Biol ; 120(1-3): 115-27, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26701222

ABSTRACT

Physiological variability manifests itself via differences in physiological function between individuals of the same species, and has crucial implications in disease progression and treatment. Despite its importance, physiological variability has traditionally been ignored in experimental and computational investigations due to averaging over samples from multiple individuals. Recently, modelling frameworks have been devised for studying mechanisms underlying physiological variability in cardiac electrophysiology and pro-arrhythmic risk under a variety of conditions and for several animal species as well as human. One such methodology exploits populations of cardiac cell models constrained with experimental data, or experimentally-calibrated populations of models. In this review, we outline the considerations behind constructing an experimentally-calibrated population of models and review the studies that have employed this approach to investigate variability in cardiac electrophysiology in physiological and pathological conditions, as well as under drug action. We also describe the methodology and compare it with alternative approaches for studying variability in cardiac electrophysiology, including cell-specific modelling approaches, sensitivity-analysis based methods, and populations-of-models frameworks that do not consider the experimental calibration step. We conclude with an outlook for the future, predicting the potential of new methodologies for patient-specific modelling extending beyond the single virtual physiological human paradigm.


Subject(s)
Electrophysiological Phenomena , Heart/physiology , Models, Cardiovascular , Calibration , Humans , User-Computer Interface
9.
PLoS One ; 9(2): e90112, 2014.
Article in English | MEDLINE | ID: mdl-24587229

ABSTRACT

Variability is observed at all levels of cardiac electrophysiology. Yet, the underlying causes and importance of this variability are generally unknown, and difficult to investigate with current experimental techniques. The aim of the present study was to generate populations of computational ventricular action potential models that reproduce experimentally observed intercellular variability of repolarisation (represented by action potential duration) and to identify its potential causes. A systematic exploration of the effects of simultaneously varying the magnitude of six transmembrane current conductances (transient outward, rapid and slow delayed rectifier K(+), inward rectifying K(+), L-type Ca(2+), and Na(+)/K(+) pump currents) in two rabbit-specific ventricular action potential models (Shannon et al. and Mahajan et al.) at multiple cycle lengths (400, 600, 1,000 ms) was performed. This was accomplished with distributed computing software specialised for multi-dimensional parameter sweeps and grid execution. An initial population of 15,625 parameter sets was generated for both models at each cycle length. Action potential durations of these populations were compared to experimentally derived ranges for rabbit ventricular myocytes. 1,352 parameter sets for the Shannon model and 779 parameter sets for the Mahajan model yielded action potential duration within the experimental range, demonstrating that a wide array of ionic conductance values can be used to simulate a physiological rabbit ventricular action potential. Furthermore, by using clutter-based dimension reordering, a technique that allows visualisation of multi-dimensional spaces in two dimensions, the interaction of current conductances and their relative importance to the ventricular action potential at different cycle lengths were revealed. Overall, this work represents an important step towards a better understanding of the role that variability in current conductances may play in experimentally observed intercellular variability of rabbit ventricular action potential repolarisation.


Subject(s)
Action Potentials/physiology , Heart Ventricles/metabolism , Models, Statistical , Potassium/metabolism , Software , Animals , Calcium/metabolism , Calcium Channels, L-Type/metabolism , Ion Transport , Multifactor Dimensionality Reduction , Potassium Channels, Calcium-Activated/metabolism , Potassium Channels, Inwardly Rectifying/metabolism , Potassium Channels, Voltage-Gated/metabolism , Rabbits , Sodium/metabolism , Sodium-Potassium-Exchanging ATPase/metabolism
10.
Article in English | MEDLINE | ID: mdl-21096193

ABSTRACT

Computational models for cardiomyocyte action potentials (AP) often make use of a large parameter set. This parameter set can contain some elements that are fitted to experimental data independently of any other element, some elements that are derived concurrently with other elements to match experimental data, and some elements that are derived purely from phenomenological fitting to produce the desired AP output. Furthermore, models can make use of several different data sets, not always derived for the same conditions or even the same species. It is consequently uncertain whether the parameter set for a given model is physiologically accurate. Furthermore, it is only recently that the possibility of degeneracy in parameter values in producing a given simulation output has started to be addressed. In this study, we examine the effects of varying two parameters (the L-type calcium current (I(CaL)) and the delayed rectifier potassium current (I(Ks))) in a computational model of a rabbit ventricular cardiomyocyte AP on both the membrane potential (V(m)) and calcium (Ca(2+)) transient. It will subsequently be determined if there is degeneracy in this model to these parameter values, which will have important implications on the stability of these models to cell-to-cell parameter variation, and also whether the current methodology for generating parameter values is flawed. The accuracy of AP duration (APD) as an indicator of AP shape will also be assessed.


Subject(s)
Calcium/chemistry , Heart Ventricles/pathology , Action Potentials , Animals , Calcium Signaling , Computer Simulation , Heart Ventricles/cytology , Ions , Membrane Potentials , Models, Cardiovascular , Myocytes, Cardiac/cytology , Potassium/chemistry , Rabbits , Reproducibility of Results , Software , Stochastic Processes