Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 334
Filter
1.
Eur Heart J ; 2024 May 15.
Article in English | MEDLINE | ID: mdl-38747561

ABSTRACT

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all (100%; 95% confidence interval [CI] 94-100.0%, p<0.001) patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 (98.3%; 95% CI [91.1-100%]) patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1-99.0%). Within 90 days, freedom from mortality was 95% (95% CI 86.1-99.0%]), without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favorable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.

2.
Article in English | MEDLINE | ID: mdl-38764317

ABSTRACT

BACKGROUND: Data using real-world assessments of aortic regurgitation (AR) severity to identify rates of Heart Valve Team evaluation and aortic valve replacement (AVR), as well as mortality among untreated patients, are lacking. The present study assessed these trends in care and outcomes for real-world patients with documented AR. METHODS: Using a deidentified data set (January 2018-March 2023) representing 1,002,853 patients >18 years of age from 25 US institutions participating in the egnite Database (egnite, Inc.) with appropriate permissions, patients were classified by AR severity in echocardiographic reports. Rates of evaluation by the Heart Valve Team, AVR, and all-cause mortality without AVR were examined using Kaplan-Meier estimates and compared using the log-rank test. RESULTS: Within the data set, 845,113 patients had AR severity documented. For moderate-to-severe or severe AR, respectively, 2-year rates (95% confidence interval) of evaluation by the Heart Valve Team (43.5% [41.7%-45.3%] and 65.4% [63.3%-67.4%]) and AVR (19.4% [17.6%-21.1%] and 46.5% [44.2%-48.8%]) were low. Mortality at 2 years without AVR increased with greater AR severity, up to 20.7% for severe AR (p < 0.001). In exploratory analyses, 2-year mortality for untreated patients with left ventricular end-systolic dimension index > 25 mm/m2 was similar for moderate (34.3% [29.2%-39.1%]) and severe (37.2% [24.9%-47.5%]) AR. CONCLUSIONS: Moderate or greater AR is associated with poor clinical outcomes among untreated patients at 2 years. Rates of Heart Valve Team evaluation and AVR were low for those with moderate or greater AR, suggesting that earlier referral to the Heart Valve Team could be beneficial.

3.
EuroIntervention ; 20(9): 536-550, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726720

ABSTRACT

The identification and management of patients at high bleeding risk (HBR) undergoing transcatheter aortic valve implantation (TAVI) are of major importance, but the lack of standardised definitions is challenging for trial design, data interpretation, and clinical decision-making. The Valve Academic Research Consortium for High Bleeding Risk (VARC-HBR) is a collaboration among leading research organisations, regulatory authorities, and physician-scientists from Europe, the USA, and Asia, with a major focus on TAVI-related bleeding. VARC-HBR is an initiative of the CERC (Cardiovascular European Research Center), aiming to develop a consensus definition of TAVI patients at HBR, based on a systematic review of the available evidence, to provide consistency for future clinical trials, clinical decision-making, and regulatory review. This document represents the first pragmatic approach to a consistent definition of HBR evaluating the safety and effectiveness of procedures, devices and drug regimens for patients undergoing TAVI..


Subject(s)
Consensus , Hemorrhage , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Risk Factors , Hemorrhage/etiology , Risk Assessment , Aortic Valve Stenosis/surgery , Aortic Valve/surgery
4.
Struct Heart ; 8(3): 100294, 2024 May.
Article in English | MEDLINE | ID: mdl-38799804

ABSTRACT

Background: Treatment options for patients with mitral regurgitation (MR) and mitral annular calcification (MAC) are limited. The limitations of current transcatheter mitral valve replacement (TMVR) technologies include high screen failure rates, increased risk of left ventricular outflow tract obstruction, and high residual regurgitation. The aim of this study was to evaluate outcomes of TMVR with the AltaValve system (4C Medical, Maple Grove, MN), a supra-annular TMVR with atrial fixation, in patients with severe MR and moderate or severe MAC. Methods: Six patients with moderate or severe MAC who were treated with AltaValve TMVR had procedural and mid-term outcomes available. Results: Technical success was achieved in all patients. Median follow-up was 232 days. At discharge, 80% of patients had none/trace MR, and 20% had mild MR. There was no intraprocedural mortality, device malposition, embolization, or thrombosis. One patient expired 3 days postprocedure due to complications related to the transapical access. All other patients were discharged from the hospital without issues. Echocardiography assessments at 30 days showed complete resolution of MR in all patients, with 1 patient with mild MR and a mean mitral valve gradient of 3.7 ± 1.4 mmHg. All patients were in New York Heart Association Class I/II at 30-day follow-up, showing marked improvement as compared with baseline. Conclusions: In patients with severe MR and severe MAC, the AltaValve TMVR technology may represent a viable treatment option. The atrial fixation minimizes the risk of left ventricular outflow tract obstruction and potentially expands treatable patients, especially in patients with MAC.

5.
JACC Cardiovasc Interv ; 17(8): 1032-1044, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38456883

ABSTRACT

BACKGROUND: The fifth-generation SAPIEN 3 Ultra Resilia valve (S3UR) incorporates several design changes as compared with its predecessors, the SAPIEN 3 (S3) and SAPIEN 3 Ultra (S3U) valves, including bovine leaflets treated with a novel process intended to reduce structural valve deterioration via calcification, as well as a taller external skirt on the 29-mm valve size to reduce paravalvular leak (PVL). The clinical performance of S3UR compared with S3 and S3U in a large patient population has not been previously reported. OBJECTIVES: The aim of this study was to compare S3UR to S3/S3U for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes after transcatheter aortic valve replacement (TAVR). METHODS: Patients enrolled in the STS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between January 1, 2021, and June 30, 2023, who underwent TAVR with S3UR or S3U/S3 valve platforms were propensity-matched and evaluated for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes. RESULTS: 10,314 S3UR patients were propensity matched with 10,314 patients among 150,539 S3U/S3 patients. At 30 days, there were no statistically significant differences in death, stroke, or bleeding, but a numerically higher hospital readmission rate in the S3UR cohort (8.5% vs 7.7%; P = 0.04). At discharge, S3UR patients exhibited significantly lower mean gradients (9.2 ± 4.6 mm Hg vs 12.0 ± 5.7 mm Hg; P < 0.0001) and larger aortic valve area (2.1 ± 0.7 cm2 vs 1.9 ± 0.6 cm2; P < 0.0001) than patients treated with S3/S3U. The 29-mm valve size exhibited significant reduction in mild PVL (5.3% vs 9.4%; P < 0.0001). CONCLUSIONS: S3UR TAVR is associated with lower mean gradients and lower rates of PVL than earlier generations of balloon expandable transcatheter heart valve platforms.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Balloon Valvuloplasty , Heart Valve Prosthesis , Prosthesis Design , Recovery of Function , Registries , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Balloon Valvuloplasty/adverse effects , Hemodynamics , Postoperative Complications/etiology , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , United States
6.
JACC Basic Transl Sci ; 9(1): 33-42, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38362340

ABSTRACT

von Willebrand Factor (VWF) destruction is common with current heart pumps. This study evaluates VWF activity with ModulHeart, a novel device using 3 micropumps in parallel. In model 1, ModulHeart was compared with Impella devices in vitro. In model 2, 3 healthy swine received ModulHeart. Model 3 includes VWF data from patients who underwent protected percutaneous coronary intervention with ModulHeart. In models 1, 2, and 3, ModulHeart resulted in preservation of VWF, whereas there was a 27% and 19% reduction in VWF activity with the Impella CP and 5.0, respectively. ModulHeart features a unique design and demonstrated preservation of VWF activity.

8.
Am Heart J ; 268: 94-103, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38056546

ABSTRACT

BACKGROUND: For patients with asymptomatic, severe aortic stenosis (AS) and preserved left ventricular ejection fraction, current guidelines recommend clinical surveillance every 6 to 12 months. To date, no randomized trials have examined whether an early intervention with transcatheter aortic valve replacement (TAVR) will improve outcomes among these patients. STUDY DESIGN AND OBJECTIVES: EARLY TAVR is a prospective, randomized, controlled, and multicenter trial, with an event-based design. Asymptomatic severe AS patients (n = 900) are randomized 1:1 to either clinical surveillance or TAVR with the Edwards SAPIEN 3/SAPIEN 3 Ultra transcatheter heart valve. Patients are stratified by whether they are able to perform a treadmill stress test. The primary end point is death, stroke, or unplanned cardiovascular hospitalization. Patients who are asymptomatic but have a positive stress test will be followed in a registry and undergo aortic valve replacement as per current guidelines. CONCLUSIONS: EARLY TAVR is the largest randomized trial to date assessing the role of early intervention among patients with asymptomatic severe AS compared to clinical surveillance and the first to study the role of TAVR. TRIAL REGISTRATION NUMBER: NCT03042104.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/epidemiology , Stroke Volume , Prospective Studies , Risk Factors , Treatment Outcome , Ventricular Function, Left , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Severity of Illness Index
10.
Artif Organs ; 48(1): 61-69, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37787101

ABSTRACT

BACKGROUND: ModulHeart (Puzzle Medical Devices Inc) is a novel percutaneous flow entrainment pump anchored in the descending aorta. The current study evaluates the hemodynamic effect of ModulHeart support and its impact on cerebral, myocardial, and renal blood flow. METHODS: ModulHeart was implanted in the descending aorta of four healthy calves. A ramp protocol (2000 RPM increments) was performed with the pump operating at five different speeds from 14 000 to 22 000 RPM. For each speed, pressures proximal and distal to the pump, and right heart catheterization measurements were recorded. Stable-isotope labeled microspheres were injected in the left ventricle to evaluate organ perfusion. RESULTS: Thermodilution cardiac output increased by 23% at 22 000 RPM. Greater pump speeds resulted in greater pump gradients, up to 10 mm Hg in mean arterial pressure at 22 000 RPM, without significant reduction of proximal perfusion pressures. Arterial pulse pressure remained stable at all speeds. ModulHeart was not associated with a reduction in cerebral or myocardial blood flow at any speed. Renal cortical and medullary blood flow increased by up to 50% and 40%, respectively. CONCLUSION: The ModulHeart device implanted in the descending aorta of healthy calves resulted in significant arterial pressure gradients and preserved pulse pressure. Greater pump speeds translated into greater increases in renal blood flow, with no decrease in cerebral or myocardial perfusion.


Subject(s)
Heart Failure , Heart-Assist Devices , Animals , Cattle , Humans , Heart Failure/therapy , Hemodynamics/physiology , Blood Pressure , Myocardium , Heart Ventricles
12.
N Engl J Med ; 389(21): 1949-1960, 2023 Nov 23.
Article in English | MEDLINE | ID: mdl-37874020

ABSTRACT

BACKGROUND: A previous analysis in this trial showed that among patients with severe, symptomatic aortic stenosis who were at low surgical risk, the rate of the composite end point of death, stroke, or rehospitalization at 1 year was significantly lower with transcatheter aortic-valve replacement (TAVR) than with surgical aortic-valve replacement. Longer-term outcomes are unknown. METHODS: We randomly assigned patients with severe, symptomatic aortic stenosis and low surgical risk to undergo either TAVR or surgery. The first primary end point was a composite of death, stroke, or rehospitalization related to the valve, the procedure, or heart failure. The second primary end point was a hierarchical composite that included death, disabling stroke, nondisabling stroke, and the number of rehospitalization days, analyzed with the use of a win ratio analysis. Clinical, echocardiographic, and health-status outcomes were assessed through 5 years. RESULTS: A total of 1000 patients underwent randomization: 503 patients were assigned to undergo TAVR, and 497 to undergo surgery. A component of the first primary end point occurred in 111 of 496 patients in the TAVR group and in 117 of 454 patients in the surgery group (Kaplan-Meier estimates, 22.8% in the TAVR group and 27.2% in the surgery group; difference, -4.3 percentage points; 95% confidence interval [CI], -9.9 to 1.3; P = 0.07). The win ratio for the second primary end point was 1.17 (95% CI, 0.90 to 1.51; P = 0.25). The Kaplan-Meier estimates for the components of the first primary end point were as follows: death, 10.0% in the TAVR group and 8.2% in the surgery group; stroke, 5.8% and 6.4%, respectively; and rehospitalization, 13.7% and 17.4%. The hemodynamic performance of the valve, assessed according to the mean (±SD) valve gradient, was 12.8±6.5 mm Hg in the TAVR group and 11.7±5.6 mm Hg in the surgery group. Bioprosthetic-valve failure occurred in 3.3% of the patients in the TAVR group and in 3.8% of those in the surgery group. CONCLUSIONS: Among low-risk patients with severe, symptomatic aortic stenosis who underwent TAVR or surgery, there was no significant between-group difference in the two primary composite outcomes. (Funded by Edwards Lifesciences; PARTNER 3 ClinicalTrials.gov number, NCT02675114.).


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Postoperative Complications/etiology , Risk Factors , Stroke/epidemiology , Stroke/etiology , Stroke/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , Follow-Up Studies , Patient Readmission , Heart Failure/etiology
13.
J Am Coll Cardiol ; 82(22): 2101-2109, 2023 11 28.
Article in English | MEDLINE | ID: mdl-37877909

ABSTRACT

BACKGROUND: The American College of Cardiology/American Heart Association guidelines recommend the assessment and grading of severity of aortic stenosis (AS) as mild, moderate, or severe, per echocardiogram, and recommend aortic valve replacement (AVR) when the AS is severe. OBJECTIVES: The authors sought to describe mortality rates across the entire spectrum of untreated AS from a contemporary, large, real-world database. METHODS: We analyzed a deidentified real-world data set including 1,669,536 echocardiographic reports (1,085,850 patients) from 24 U.S. hospitals (egnite Database, egnite). Patients >18 years of age were classified by diagnosed AS severity. Untreated mortality and treatment rates were examined with Kaplan-Meier (KM) estimates, with results compared using the log-rank test. Multivariate hazards analysis was performed to assess associations with all-cause mortality. RESULTS: Among 595,120 patients with available AS severity assessment, the KM-estimated 4-year unadjusted, untreated, all-cause mortality associated with AS diagnosis of none, mild, mild-to-moderate, moderate, moderate-to-severe, or severe was 13.5% (95% CI: 13.3%-13.7%), 25.0% (95% CI: 23.8%-26.1%), 29.7% (95% CI: 26.8%-32.5%), 33.5% (95% CI: 31.0%-35.8%), 45.7% (95% CI: 37.4%-52.8%), and 44.9% (95% CI: 39.9%-49.6%), respectively. Results were similar when adjusted for informative censoring caused by treatment. KM-estimated 4-year observed treatment rates were 0.2% (95% CI: 0.2%-0.2%), 1.0% (95% CI: 0.7%-1.3%), 4.2% (95% CI: 2.0%-6.3%), 11.4% (95% CI: 9.5%-13.3%), 36.7% (95% CI: 31.8%-41.2%), and 60.7% (95% CI: 58.0%-63.3%), respectively. After adjustment, all degrees of AS severity were associated with increased mortality. CONCLUSIONS: Patients with AS have high mortality risk across all levels of untreated AS severity. Aortic valve replacement rates remain low for patients with severe AS, suggesting that more research is needed to understand barriers to diagnosis and appropriate approach and timing for aortic valve replacement.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Humans , Treatment Outcome , Heart Valve Prosthesis Implantation/methods , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Echocardiography , Severity of Illness Index , Risk Factors
14.
Atherosclerosis ; : 117264, 2023 Sep 03.
Article in English | MEDLINE | ID: mdl-37726192

ABSTRACT

BACKGROUND AND AIMS: Diabetes-mellitus (DM) is associated with increased risk of neointimal hyperplasia (NIH) and restenosis after percutaneous coronary intervention (PCI). We examined a possible association of DM severity at the time of PCI with the development of NIH. METHODS: This post-hoc analysis from the BLADE-PCI randomized, multi-center trial included only patients with DM and baseline data of HbA1c within 14 days prior to the index PCI. All patients were treated with zotarolimus-eluting stents. The primary endpoint was percent of NIH volume at 9 months as evaluated by optical coherence tomography. This endpoint was compared between patients with uncontrolled DM (HbA1c ≥ 7.5%) and controlled DM (HbA1c <7.5%) at the index PCI. RESULTS: The mean percentages of NIH volume were 16.5% ± 9.9 and 12.75% ± 7.9 among patients with baseline HbA1c ≥ 7.5% (n = 74) and <7.5% (n = 102), respectively (p < 0.05). In multivariable analysis, HbA1c ≥ 7.5% was not associated with higher risk of NIH development [95% CI; 2.2 (-0.8, 5.3; p = 0.15)]. Higher HbA1c was not associated with increased risk of NIH at the minimum lumen area site [95% CI; 0.9 (-5.0, 6.7); p = 0.77) or percent stent strut coverage [95% CI; -0.3 (-1.3, 0.6); p = 0.45]. Secondary clinical endpoints including major adverse cardiac and cerebrovascular events, target lesion failure and death were similar between patients with worse and better DM control. CONCLUSIONS: Uncontrolled DM at the time of PCI performed with contemporary drug-eluting stents was not associated with an increased risk of NIH development.

15.
Am J Cardiol ; 204: 276-283, 2023 10 01.
Article in English | MEDLINE | ID: mdl-37562193

ABSTRACT

It is unknown whether gender influences the atherosclerotic plaque characteristics (APCs) of lesions of varying angiographic stenosis severity. This study evaluated the imaging data of 303 symptomatic patients from the derivation arm of the CREDENCE (Computed TomogRaphic Evaluation of Atherosclerotic Determinants of Myocardial IsChEmia) trial, all of whom underwent coronary computed tomographic angiography and clinically indicated nonemergent invasive coronary angiography upon study enrollment. Index tests were interpreted by 2 blinded core laboratories, one of which performed quantitative coronary computed tomographic angiography using an artificial intelligence application to characterize and quantify APCs, including percent atheroma volume (PAV), low-density noncalcified plaque (LD-NCP), noncalcified plaque (NCP), calcified plaque (CP), lesion length, positive arterial remodeling, and high-risk plaque (a combination of LD-NCP and positive remodeling ≥1.10); the other classified lesions as obstructive (≥50% diameter stenosis) or nonobstructive (<50% diameter stenosis) based on quantitative invasive coronary angiography. The relation between APCs and angiographic stenosis was further examined by gender. The mean age of the study cohort was 64.4 ± 10.2 years (29.0% female). In patients with obstructive disease, men had more LD-NCP PAV (0.5 ± 0.4 vs 0.3 ± 0.8, p = 0.03) and women had more CP PAV (11.7 ± 1.6 vs 8.0 ± 0.8, p = 0.04). Obstructive lesions had more NCP PAV compared with their nonobstructive lesions in both genders, however, obstructive lesions in women also demonstrated greater LD-NCP PAV (0.4 ± 0.5 vs 1.0 ± 1.8, p = 0.03), and CP PAV (17.4 ± 16.5 vs 25.9 ± 18.7, p = 0.03) than nonobstructive lesions. Comparing the composition of obstructive lesions by gender, women had more CP PAV (26.3 ± 3.4 vs 15.8 ± 1.5, p = 0.005) whereas men had more NCP PAV (33.0 ± 1.6 vs 26.7 ± 2.5, p = 0.04). Men had more LD-NCP PAV in nonobstructive lesions compared with women (1.2 ± 0.2 vs 0.6 ± 0.2, p = 0.02). In conclusion, there are gender-specific differences in plaque composition based on stenosis severity.


Subject(s)
Coronary Artery Disease , Coronary Stenosis , Plaque, Atherosclerotic , Humans , Female , Male , Middle Aged , Aged , Plaque, Atherosclerotic/diagnostic imaging , Constriction, Pathologic , Artificial Intelligence , Coronary Angiography/methods , Computed Tomography Angiography/methods , Predictive Value of Tests , Severity of Illness Index
16.
J Am Coll Cardiol ; 82(4): 295-313, 2023 07 25.
Article in English | MEDLINE | ID: mdl-37468185

ABSTRACT

BACKGROUND: The impact of complete revascularization (CR) on angina-related health status (symptoms, function, quality of life) in chronic coronary disease (CCD) has not been well studied. OBJECTIVES: Among patients with CCD randomized to invasive (INV) vs conservative (CON) management in ISCHEMIA (International Study of Comparative Health Effectiveness with Medical and Invasive Approaches), we compared the following: 1) the impact of anatomic and functional CR on health status compared with incomplete revascularization (ICR); and 2) the predicted impact of achieving CR in all INV patients compared with CON. METHODS: Multivariable regression adjusting for patient characteristics was used to compare 12-month health status after independent core laboratory-defined CR vs ICR in INV patients who underwent revascularization. Propensity-weighted modeling was then performed to estimate the treatment effect had CR or ICR been achieved in all INV patients, compared with CON. RESULTS: Anatomic and functional CR were achieved in 43.3% and 57.8% of 1,641 INV patients, respectively. Among revascularized patients, CR was associated with improved Seattle Angina Questionnaire Angina Frequency compared with ICR after adjustment for baseline differences. After modeling CR and ICR in all INV patients, patients with CR and ICR each had greater improvements in health status than CON, with better health status with CR than ICR. The projected benefits of CR were most pronounced in patients with baseline daily/weekly angina and not seen in those with no angina. CONCLUSIONS: Among patients with CCD in ISCHEMIA, health status improved more with CR compared with ICR or CON, particularly in those with frequent angina. Anatomic and functional CR provided comparable improvements in quality of life. (International Study of Comparative Health Effectiveness With Medical and Invasive Approaches [ISCHEMIA]; NCT01471522).


Subject(s)
Coronary Artery Disease , Quality of Life , Humans , Treatment Outcome , Angina Pectoris/epidemiology , Angina Pectoris/surgery , Health Status , Myocardial Revascularization , Ischemia
17.
J Am Coll Cardiol ; 82(12): 1175-1188, 2023 09 19.
Article in English | MEDLINE | ID: mdl-37462593

ABSTRACT

BACKGROUND: Anatomic complete revascularization (ACR) and functional complete revascularization (FCR) have been associated with reduced death and myocardial infarction (MI) in some prior studies. The impact of complete revascularization (CR) in patients undergoing an invasive (INV) compared with a conservative (CON) management strategy has not been reported. OBJECTIVES: Among patients with chronic coronary disease without prior coronary artery bypass grafting randomized to INV vs CON management in the ISCHEMIA (International Study of Comparative Health Effectiveness with Medical and Invasive Approaches) trial, we examined the following: 1) the outcomes of ACR and FCR compared with incomplete revascularization; and 2) the potential impact of achieving CR in all INV patients compared with CON management. METHODS: ACR and FCR in the INV group were assessed at an independent core laboratory. Multivariable-adjusted outcomes of CR were examined in INV patients. Inverse probability weighted modeling was then performed to estimate the treatment effect had CR been achieved in all INV patients compared with CON management. RESULTS: ACR and FCR were achieved in 43.4% and 58.4% of 1,824 INV patients. ACR was associated with reduced 4-year rates of cardiovascular death or MI compared with incomplete revascularization. By inverse probability weighted modeling, ACR in all 2,296 INV patients compared with 2,498 CON patients was associated with a lower 4-year rate of cardiovascular death or MI (difference -3.5; 95% CI: -7.2% to 0.0%). In comparison, the event rate difference of cardiovascular death or MI for INV minus CON in the overall ISCHEMIA trial was -2.4%. Results were similar but less pronounced with FCR. CONCLUSIONS: The outcomes of an INV strategy may be improved if CR (especially ACR) is achieved. (International Study of Comparative Health Effectiveness With Medical and Invasive Approaches [ISCHEMIA]; NCT01471522).


Subject(s)
Coronary Artery Disease , Myocardial Infarction , Percutaneous Coronary Intervention , Humans , Myocardial Infarction/surgery , Coronary Artery Bypass , Treatment Outcome , Coronary Artery Disease/surgery , Myocardial Revascularization/methods
18.
J. Am. Coll. Cardiol ; 82(12): 1175-1188, jun.2023. ilus
Article in English | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1443661

ABSTRACT

BACKGROUND: Anatomic complete revascularization (ACR) and functional complete revascularization (FCR) have been associated with reduced death and myocardial infarction (MI) in some prior studies. The impact of complete revascularization (CR) in patients undergoing an invasive (INV) compared with a conservative (CON) management strategy has not been reported. OBJECTIVES: Among patients with chronic coronary disease without prior coronary artery bypass grafting randomized to INV vs CON management in the ISCHEMIA (International Study of Comparative Health Effectiveness with Medical and Invasive Approaches) trial, we examined the following: 1) the outcomes of ACR and FCR compared with incomplete revascularization; and 2) the potential impact of achieving CR in all INV patients compared with CON management. METHODS: ACR and FCR in the INV group were assessed at an independent core laboratory. Multivariable-adjusted outcomes of CR were examined in INV patients. Inverse probability weighted modeling was then performed to estimate the treatment effect had CR been achieved in all INV patients compared with CON management. RESULTS: ACR and FCR were achieved in 43.4% and 58.4% of 1,824 INV patients. ACR was associated with reduced 4-year rates of cardiovascular death or MI compared with incomplete revascularization. By inverse probability weighted modeling, ACR in all 2,296 INV patients compared with 2,498 CON patients was associated with a lower 4-year rate of cardiovascular death or MI (difference -3.5; 95% CI: -7.2% to 0.0%). In comparison, the event rate difference of cardiovascular death or MI for INV minus CON in the overall ISCHEMIA trial was -2.4%. Results were similar but less pronounced with FCR. CONCLUSIONS: The outcomes of an INV strategy may be improved if CR (especially ACR) is achieved. (International Study of Comparative Health Effectiveness With Medical and Invasive Approaches [ISCHEMIA]; NCT01471522).


Subject(s)
Coronary Artery Disease
19.
JACC Cardiovasc Imaging ; 16(6): 837-855, 2023 06.
Article in English | MEDLINE | ID: mdl-36881428

ABSTRACT

Current guidelines recommend that clinical surveillance for patients with moderate aortic stenosis (AS) and aortic valve replacement (AVR) may be considered if there is an indication for coronary revascularization. Recent observational studies, however, have shown that moderate AS is associated with an increased risk of cardiovascular events and mortality. Whether the increased risk of adverse events is caused by associated comorbidities, or to the underlying moderate AS itself, is incompletely understood. Similarly, which patients with moderate AS need close follow-up or could potentially benefit from early AVR is also unknown. In this review, the authors provide a comprehensive overview of the current published reports on moderate AS. They first provide an algorithm that helps to diagnose moderate AS correctly, especially when discordant grading is observed. Although the traditional focus of AS assessment has been on the valve, it is increasingly acknowledged that AS is not only a disease of the aortic valve but also of the ventricle. The authors therefore discuss how multimodality imaging can help to evaluate the left ventricular remodeling response and improve risk stratification in patients with moderate AS. Finally, they summarize current evidence on the management of moderate AS and highlight ongoing trials on AVR in moderate AS.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Humans , Predictive Value of Tests , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Ventricular Function, Left
20.
J Am Coll Cardiol ; 81(8): 743-752, 2023 02 28.
Article in English | MEDLINE | ID: mdl-36813373

ABSTRACT

BACKGROUND: The extent of extravalvular cardiac damage is associated with increased risk of adverse events among patients with severe aortic stenosis undergoing aortic valve replacement (AVR). OBJECTIVES: The goal was to describe the association of cardiac damage on health status before and after AVR. METHODS: Patients from the PARTNER (Placement of Aortic Transcatheter Valves) 2 and 3 trials were pooled and classified by echocardiographic cardiac damage stage at baseline and 1 year as previously described (stage 0-4). We examined the association between baseline cardiac damage and 1-year health status (assessed by the Kansas City Cardiomyopathy Questionnaire Overall Score [KCCQ-OS]). RESULTS: Among 1,974 patients (794 surgical AVR, 1,180 transcatheter AVR), the extent of cardiac damage at baseline was associated with lower KCCQ scores both at baseline and at 1 year after AVR (P < 0.0001) and with increased rates of a poor outcome (death, KCCQ-OS <60, or a decrease in KCCQ-OS of ≥10 points) at 1 year (stages 0-4: 10.6% vs 19.6% vs 29.0% vs 44.7% vs 39.8%; P < 0.0001). In a multivariable model, each 1-stage increase in baseline cardiac damage was associated with a 24% increase in the odds of a poor outcome (95% CI: 9%-41%; P = 0.001). Change in stage of cardiac damage at 1 year after AVR was associated with the extent of improvement in KCCQ-OS over the same period (mean change in 1-year KCCQ-OS: improvement of ≥1 stage +26.8 [95% CI: 24.2-29.4] vs no change +21.4 [95% CI: 20.0-22.7] vs deterioration of ≥1 stage +17.5 [95% CI: 15.4-19.5]; P < 0.0001). CONCLUSIONS: The extent of cardiac damage before AVR has an important impact on health status outcomes, both cross-sectionally and after AVR. (PARTNER II Trial: Placement of AoRTic TraNscathetER Valves II - XT Intermediate and High Risk (PII A), NCT01314313; The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves - PII B [PARTNERII B], NCT02184442; PARTNER 3 Trial: Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low Risk Patients With Aortic Stenosis [P3], NCT02675114).


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/surgery , Quality of Life , Treatment Outcome , Health Status , Aortic Valve Stenosis/surgery , Risk Factors , Severity of Illness Index
SELECTION OF CITATIONS
SEARCH DETAIL
...