Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Endosc Ultrasound ; 6(6): 394-401, 2017.
Article in English | MEDLINE | ID: mdl-29251274

ABSTRACT

BACKGROUND AND OBJECTIVES: Interventional endoscopic ultrasound (EUS) is a promising novel approach for intravascular interventions. The aim of this study was to assess the feasibility and safety of a EUS-guided intrahepatic portosystemic shunt (EGIPS) with portal pressure gradient measurement in a live porcine model. METHODS: The left hepatic vein (LHV) or the inferior vena cava (IVC) was punctured with a needle that advanced into the portal vein (PV). A guidewire was then inserted into the PV, and a needle knife was used to create an intrahepatic fistula between LHV and PV. Portal pressure was recorded. The fistula was dilated with a balloon and a biliary metal stent was deployed between LHV and PV under sonographic and fluoroscopic observation. A portocavography validated the patency of the stent. Necropsies were realized after euthanasia. RESULTS: Portosystemic stenting was achieved in 19/21 pigs. Final portocavography confirmed stent patency between PV and LHV or IVC in 17 pigs (efficacy of 81%): Four stents were dysfunctional as two were thrombosed and two were poor positioned. Portal pressure was documented before and after shunting in 20/21 pigs. Necropsies revealed that 19/21 procedures were transesophageal and two were transgastric. Hemoperitoneum and pneumothorax were found in one pig and hemothorax was found in two pigs. Morbidity was 14.2% (3/21 animals). CONCLUSION: EGIPS was feasible in 91% of cases, functional in 81%, with 14.2% per procedure morbidity. EGIPS still needs to be assessed in portal hypertension pig models with longer follow-up before being considered as an alternative when the transjugular intrahepatic portosystemic shunt fails.

2.
Inflamm Bowel Dis ; 23(8): 1425-1433, 2017 08.
Article in English | MEDLINE | ID: mdl-28570431

ABSTRACT

BACKGROUND: Objective control of intestinal inflammation during inflammatory bowel disease (IBD) is becoming the main driver for medical treatment. However, the monitoring tools-related burden remains poorly investigated. We aimed to evaluate their comparative acceptability and utility according to patients with IBD. METHODS: After a preliminary phase, the final questionnaire encompassing self-administered and physician questionnaires was prospectively and consecutively submitted to 916 patients with IBD from 20 public and private centers. Acceptability and utility visual analog scales (VAS) were expressed as median with interquartile range. RESULTS: Regarding the group of patients with Crohn's disease (n = 618), venipuncture (VAS = 9.3 [8.8-9.7]) and ultrasonography (VAS = 9.3 [8.7-9.7]) were the most acceptable tools (P < 0.0001, for each comparison), whereas rectosigmoidoscopy was the least acceptable tool (VAS = 4.4 [1.2-7.3]) (P < 0.0001, for each comparison). Wireless capsule endoscopy (VAS = 8.5 [5.2-9.3]), magnetic resonance enterocolonography (VAS = 8.0 [5.0-9.2]), and stools collection (VAS = 7.7 [4.6-9.3]) were more acceptable than colonoscopy (VAS = 6.7 [4.3-8.9]) (P < 0.0001, for each comparison). The acceptability was assessed in 298 patients with ulcerative colitis for venipuncture (VAS = 9.4 [8.8-9.7]), stools collection (VAS = 8.1 [5.7-9.4]), colonoscopy (VAS = 7.5 [4.7-9.2]), and rectosigmoidoscopy (VAS = 6.7 [2.8-9.1]); (P < 0.001 for each comparison). All monitoring tools were considered as highly useful by patients with IBD. Decreased acceptability was related to embarrassment for the collection/transport of stools (60.7%), bowel cleansing (76.3%) for colonoscopy, abdominal discomfort (51.3%) and rectal enema (36.6%) for rectosigmoidoscopy, bowel distension (48.3%) for magnetic resonance enterocolonography, and potential capsule retention (21.4%) for wireless capsule endoscopy. CONCLUSIONS: Among the IBD monitoring tools, endoscopy demonstrated the lowest acceptability supporting the development of alternative modalities. Patients' information and examination conditions should be improved to ensure proper monitoring adherence.


Subject(s)
Capsule Endoscopy , Colonoscopy , Inflammatory Bowel Diseases/diagnosis , Ultrasonography , Adult , Biomarkers/analysis , Female , Follow-Up Studies , Humans , Inflammatory Bowel Diseases/diagnostic imaging , Male , Perception , Prognosis , Prospective Studies , Surveys and Questionnaires
SELECTION OF CITATIONS
SEARCH DETAIL
...