Article in English | MEDLINE | ID: mdl-39219714

ABSTRACT

Surgical reattachment of tendon to bone is a clinical challenge, with unacceptably high retear rates in the early period after repair. A primary reason for these repeated tears is that the multiscale toughening mechanisms found at the healthy tendon enthesis are not regenerated during tendon-to-bone healing. The need for technologies to improve these outcomes is pressing, and the tissue engineering community has responded with many advances that hold promise for eventually regenerating the multiscale tissue interface that transfers loads between the two dissimilar materials, tendon, and bone. This review provides an assessment of the state of these approaches, with the aim of identifying a critical agenda for future progress.

2.
Adv Healthc Mater ; : e2401550, 2024 Jul 29.
Article in English | MEDLINE | ID: mdl-39075933

ABSTRACT

Alginate hydrogels are widely used as biomaterials for cell culture and tissue engineering due to their biocompatibility and tunable mechanical properties. Reducing alginate molecular weight is an effective strategy for modulating hydrogel viscoelasticity and stress relaxation behavior, which can significantly impact cell spreading and fate. However, current methods like gamma irradiation to produce low molecular weight alginates suffer from high cost and limited accessibility. Here, a facile and cost-effective approach to reduce alginate molecular weight in a highly controlled manner using serial autoclaving is presented. Increasing the number of autoclave cycles results in proportional reductions in intrinsic viscosity, hydrodynamic radius, and molecular weight of the polymer while maintaining its chemical composition. Hydrogels fabricated from mixtures of the autoclaved alginates exhibit tunable mechanical properties, with inclusion of lower molecular weight alginate leading to softer gels with faster stress relaxation behaviors. The method is demonstrated by establishing how viscoelastic relaxation affects the spreading of encapsulated fibroblasts and glioblastoma cells. Results establish repetitive autoclaving as an easily accessible technique to generate alginates with a range of molecular weights and to control the viscoelastic properties of alginate hydrogels, and demonstrate utility across applications in mechanobiology, tissue engineering, and regenerative medicine.

3.
Sci Adv ; 10(26): eadl5270, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38941456

ABSTRACT

Rotator cuff repair surgeries fail frequently, with 20 to 94% of the 600,000 repairs performed annually in the United States resulting in retearing of the rotator cuff. The most common cause of failure is sutures tearing through tendons at grasping points. To address this issue, we drew inspiration from the specialized teeth of snakes of the Pythonoidea superfamily, which grasp soft tissues without tearing. To apply this nondamaging gripping approach to the surgical repair of tendon, we developed and optimized a python tooth-inspired device as an adjunct to current rotator cuff suture repair and found that it nearly doubled repair strength. Integrated simulations, 3D printing, and ex vivo experiments revealed a relationship between tooth shape and grasping mechanics, enabling optimization of the clinically relevant device that substantially enhances rotator cuff repair by distributing stresses over the attachment footprint. This approach suggests an alternative to traditional suturing paradigms and may reduce the risk of tendon retearing after rotator cuff repair.


Subject(s)
Boidae , Rotator Cuff , Animals , Rotator Cuff/surgery , Boidae/physiology , Rotator Cuff Injuries/surgery , Tooth , Suture Techniques/instrumentation , Biomechanical Phenomena , Humans , Printing, Three-Dimensional
4.
J Endovasc Ther ; : 15266028241231513, 2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38357736

ABSTRACT

CLINICAL IMPACT: The study establishes a rapid, technically straightforward, and reproducible porcine large animal model for acute iliocaval deep vein thrombosis (DVT). The procedure can be performed with basic endovascular skillsets. With its procedural efficiency and consistency, the platform is promising for comparative in vivo testing of venous thrombectomy devices in a living host, and for future verification and validation studies to determine efficacy of novel thrombectomy devices relative to predicates.

5.
J Biomed Mater Res A ; 112(4): 534-548, 2024 04.
Article in English | MEDLINE | ID: mdl-37952251

ABSTRACT

Many types of cardiovascular disease are linked to the mechanical forces placed on the heart. However, our understanding of how mechanical forces exactly affect the cellular biology of the heart remains incomplete. In vitro models based on cardiomyocytes derived from human induced pluripotent stem cells (iPSC-CM) enable researchers to develop medium to high-throughput systems to study cardiac mechanobiology at the cellular level. Previous models have been developed to enable the study of mechanical forces, such as cardiac afterload. However, most of these models require exogenous extracellular matrix (ECM) to form cardiac tissues. Recently, a system was developed to simulate changes in afterload by grafting ECM-free micro-heart muscle arrays to elastomeric substrates of discrete stiffnesses. In the present study, we extended this system by combining the elastomer-grafted tissue arrays with a magnetorheological elastomeric substrate. This system allows iPSC-CM based micro-heart muscle arrays to experience dynamic changes in contractile resistance to mimic dynamically altered afterload. Acute changes in substrate stiffness led to acute changes in the calcium dynamics and contractile forces, illustrating the system's ability to dynamically elicit changes in tissue mechanics by dynamically changing contractile resistance.


Subject(s)
Induced Pluripotent Stem Cells , Humans , Myocytes, Cardiac , Mechanical Phenomena , Extracellular Matrix , Myocardial Contraction
6.
Nano Lett ; 24(1): 229-237, 2024 Jan 10.
Article in English | MEDLINE | ID: mdl-38146928

ABSTRACT

Rapid and accurate quantification of low-abundance protein biomarkers in biofluids can transform the diagnosis of a range of pathologies, including infectious diseases. Here, we harness ultrabright plasmonic fluors as "digital nanolabels" and demonstrate the detection and quantification of subfemtomolar concentrations of human IL-6 and SARS-CoV-2 alpha and variant proteins in clinical nasopharyngeal swab and saliva samples from COVID-19 patients. The resulting digital plasmonic fluor-linked immunosorbent assay (digital p-FLISA) enables detection of SARS-CoV-2 nucleocapsid protein, both in solution and in live virions. Digital p-FLISA outperforms the "gold standard" enzyme-linked immunosorbent assay (ELISA), having a nearly 7000-fold lower limit-of-detection, and outperforms a commercial antigen test, having over 5000-fold improvement in analytical sensitivity. Detection and quantification of very low concentrations of target proteins holds potential for early detection of pathological conditions, treatment monitoring, and personalized medicine.


Subject(s)
COVID-19 , Humans , Enzyme-Linked Immunosorbent Assay , COVID-19/diagnosis , Fluoroimmunoassay , SARS-CoV-2 , Biomarkers , Sensitivity and Specificity
7.
Article in English | MEDLINE | ID: mdl-38039085

ABSTRACT

Silk-amyloid-mussel foot protein (SAM) hydrogels made from recombinant fusion proteins containing ß-amyloid peptide, spider silk domain, and mussel foot protein (Mfp) are attractive bioadhesives as they display a unique combination of tunability, biocompatibility, bioabsorbability, strong cohesion, and underwater adhesion to a wide range of biological surfaces. To design tunable SAM hydrogels for tailored surgical repair applications, an understanding of the relationships between protein sequence and hydrogel properties is imperative. Here, we fabricated SAM hydrogels using fusion proteins of varying lengths of silk-amyloid repeats and Mfps to characterize their structure and properties. We found that increasing silk-amyloid repeats enhanced the hydrogel's ß-sheet content (r = 0.74), leading to higher cohesive strength and toughness. Additionally, increasing the Mfp length beyond the half-length of the full Mfp sequence (1/2 Mfp) decreased the ß-sheet content (r = -0.47), but increased hydrogel surface adhesion. Among different variants, the hydrogel made of 16xKLV-2Mfp displayed a high ultimate strength of 3.0 ± 0.3 MPa, an ultimate strain of 664 ± 119%, and an attractive underwater adhesivity of 416 ± 20 kPa to porcine skin. Collectively, the sequence-structure-property relationships learned from this study will be useful to guide the design of future protein adhesives with tunable characteristics for tailored surgical applications.

8.
Adv Sci (Weinh) ; 10(35): e2302421, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37849221

ABSTRACT

Dynamically evolving adhesions between cells and extracellular matrix (ECM) transmit time-varying signals that control cytoskeletal dynamics and cell fate. Dynamic cell adhesion and ECM stiffness regulate cellular mechanosensing cooperatively, but it has not previously been possible to characterize their individual effects because of challenges with controlling these factors independently. Therefore, a DNA-driven molecular system is developed wherein the integrin-binding ligand RGD can be reversibly presented and removed to achieve cyclic cell attachment/detachment on substrates of defined stiffness. Using this culture system, it is discovered that cyclic adhesion accelerates F-actin kinetics and nuclear mechanosensing in human mesenchymal stem cells (hMSCs), with the result that hysteresis can completely change how hMSCs transduce ECM stiffness. Results are dramatically different from well-known results for mechanotransduction on static substrates, but are consistent with a mathematical model of F-actin fragments retaining structure following loss of integrin ligation and participating in subsequent repolymerization. These findings suggest that cyclic integrin-mediated adhesion alters the mechanosensing of ECM stiffness by hMSCs through transient, hysteretic memory that is stored in F-actin.


Subject(s)
Actins , Integrins , Humans , Cell Adhesion/physiology , Integrins/metabolism , Actins/analysis , Actins/metabolism , Mechanotransduction, Cellular , Extracellular Matrix/metabolism
9.
Proc Natl Acad Sci U S A ; 120(38): e2212949120, 2023 09 19.
Article in English | MEDLINE | ID: mdl-37695908

ABSTRACT

Fluorescent reporters of cardiac electrophysiology provide valuable information on heart cell and tissue function. However, motion artifacts caused by cardiac muscle contraction interfere with accurate measurement of fluorescence signals. Although drugs such as blebbistatin can be applied to stop cardiac tissue from contracting by uncoupling calcium-contraction, their usage prevents the study of excitation-contraction coupling and, as we show, impacts cellular structure. We therefore developed a robust method to remove motion computationally from images of contracting cardiac muscle and to map fluorescent reporters of cardiac electrophysiological activity onto images of undeformed tissue. When validated on cardiomyocytes derived from human induced pluripotent stem cells (iPSCs), in both monolayers and engineered tissues, the method enabled efficient and robust reduction of motion artifact. As with pharmacologic approaches using blebbistatin for motion removal, our algorithm improved the accuracy of optical mapping, as demonstrated by spatial maps of calcium transient decay. However, unlike pharmacologic motion removal, our computational approach allowed direct analysis of calcium-contraction coupling. Results revealed calcium-contraction coupling to be more uniform across cells within engineered tissues than across cells in monolayer culture. The algorithm shows promise as a robust and accurate tool for optical mapping studies of excitation-contraction coupling in heart tissue.


Subject(s)
Induced Pluripotent Stem Cells , Myocytes, Cardiac , Humans , Artifacts , Calcium , Software , Calcium, Dietary , Coloring Agents
10.
bioRxiv ; 2023 Jun 05.
Article in English | MEDLINE | ID: mdl-37333419

ABSTRACT

Endovascular procedures provide surgeons and other interventionalists with minimally invasive methods to treat vascular diseases by passing guidewires, catheters, sheaths and treatment devices into the vasculature to and navigate toward a treatment site. The efficiency of this navigation affects patient outcomes, but is frequently compromised by catheter "herniation", in which the catheter-guidewire system bulges out from the intended endovascular pathway so that the interventionalist can no longer advance it. Here, we showed herniation to be a bifurcation phenomenon that can be predicted and controlled using mechanical characterizations of catheter-guidewire systems and patientspecific clinical imaging. We demonstrated our approach in laboratory models and, retrospectively, in patients who underwent procedures involving transradial neurovascular procedures with an endovascular pathway from the wrist, up in the arm, around the aortic arch, and into the neurovasculature. Our analyses identified a mathematical navigation stability criterion that predicted herniation in all of these settings. Results show that herniation can be predicted through bifurcation analysis, and provide a framework for selecting catheter-guidewire systems to avoid herniation in specific patient anatomy.

11.
ACS Biomater Sci Eng ; 9(7): 4101-4107, 2023 07 10.
Article in English | MEDLINE | ID: mdl-37288994

ABSTRACT

Model verification is a critical aspect of scientific accountability, transparency, and learning. Here, we demonstrate an application of a model verification approach for a molecular dynamics (MD) simulation, where the interactions between silica and silk protein were studied experimentally toward understanding biomineralization. Following the ten rules for credible modeling and simulation of biosciences as developed in Erdemir et al., the authors of the original paper collaborated with an external modeling group to verify the key findings of their original simulation model and to document this verification approach. The process resulted in successful replication of the key findings of the original model. Beyond verification, study of the model from a new perspective generated new insight into the basic assumptions. We discuss key learnings for how model validation processes can be improved more generally, specifically through improved documentation methods. We anticipate that this application of our protocol for model verification can be further replicated and improved to verify and validate other simulations.


Subject(s)
Biomineralization , Reproducibility of Results
12.
13.
Biophys Rev (Melville) ; 4(1): 011314, 2023 Mar.
Article in English | MEDLINE | ID: mdl-37008887

ABSTRACT

Mechanical forces impact cardiac cells and tissues over their entire lifespan, from development to growth and eventually to pathophysiology. However, the mechanobiological pathways that drive cell and tissue responses to mechanical forces are only now beginning to be understood, due in part to the challenges in replicating the evolving dynamic microenvironments of cardiac cells and tissues in a laboratory setting. Although many in vitro cardiac models have been established to provide specific stiffness, topography, or viscoelasticity to cardiac cells and tissues via biomaterial scaffolds or external stimuli, technologies for presenting time-evolving mechanical microenvironments have only recently been developed. In this review, we summarize the range of in vitro platforms that have been used for cardiac mechanobiological studies. We provide a comprehensive review on phenotypic and molecular changes of cardiomyocytes in response to these environments, with a focus on how dynamic mechanical cues are transduced and deciphered. We conclude with our vision of how these findings will help to define the baseline of heart pathology and of how these in vitro systems will potentially serve to improve the development of therapies for heart diseases.

14.
Adv Sci (Weinh) ; 10(20): e2301581, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37083263

ABSTRACT

Information processing using material's own properties has gained increasing interest. Mechanical metamaterials, due to their diversity of deformation modes and wide design space, can be used to realize information processing, such as computing and storage. Here a mechanical metamaterial system is demonstrated for material-based encoding and storage of data through programmed reconfigurations of the metamaterial's structured building blocks. Sequential encoding and decoding are achieved in the three-dimensional (3D) printed pixelated mechanical metamaterial via kirigami-based "pixels" with programmable, temperature-dependent bistability. The mechanical metamaterial is demonstrated via a multistep deformation of encoding messages of texts and surfaces with arrays of binary data, and then decoding them by applying a predetermined stretching and heating regimen to sequentially retrieve layers of stored information and display them on its surface. This approach serves as a general framework to enable the encoding and storage of data with mechanical metamaterials.

15.
Adv Drug Deliv Rev ; 196: 114771, 2023 05.
Article in English | MEDLINE | ID: mdl-36889646

ABSTRACT

Mechanical forces are central to how cancer treatments such as chemotherapeutics and immunotherapies interact with cells and tissues. At the simplest level, electrostatic forces underlie the binding events that are critical to therapeutic function. However, a growing body of literature points to mechanical factors that also affect whether a drug or an immune cell can reach a target, and to interactions between a cell and its environment affecting therapeutic efficacy. These factors affect cell processes ranging from cytoskeletal and extracellular matrix remodeling to transduction of signals by the nucleus to metastasis of cells. This review presents and critiques the state of the art of our understanding of how mechanobiology impacts drug and immunotherapy resistance and responsiveness, and of the in vitro systems that have been of value in the discovery of these effects.


Subject(s)
Biocompatible Materials , Neoplasms , Humans , Biocompatible Materials/metabolism , Extracellular Matrix/metabolism , Immunotherapy , Neoplasms/drug therapy , Neoplasms/metabolism
17.
Nat Biomed Eng ; 7(12): 1556-1570, 2023 Dec.
Article in English | MEDLINE | ID: mdl-36732621

ABSTRACT

Lateral-flow assays (LFAs) are rapid and inexpensive, yet they are nearly 1,000-fold less sensitive than laboratory-based tests. Here we show that plasmonically active antibody-conjugated fluorescent gold nanorods can make conventional LFAs ultrasensitive. With sample-to-answer times within 20 min, plasmonically enhanced LFAs read out via a standard benchtop fluorescence scanner attained about 30-fold improvements in dynamic range and in detection limits over 4-h-long gold-standard enzyme-linked immunosorbent assays, and achieved 95% clinical sensitivity and 100% specificity for antibodies in plasma and for antigens in nasopharyngeal swabs from individuals with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Comparable improvements in the assay's performance can also be achieved via an inexpensive portable scanner, as we show for the detection of interleukin-6 in human serum samples and of the nucleocapsid protein of SARS-CoV-2 in nasopharyngeal samples. Plasmonically enhanced LFAs outperform standard laboratory tests in sensitivity, speed, dynamic range, ease of use and cost, and may provide advantages in point-of-care diagnostics.


Subject(s)
Immunoconjugates , Nanoparticles , Humans , SARS-CoV-2 , Enzyme-Linked Immunosorbent Assay , Antibodies , Point-of-Care Testing
18.
Biophys J ; 122(1): 43-53, 2023 01 03.
Article in English | MEDLINE | ID: mdl-36451545

ABSTRACT

Cells translate mechanical cues from the extracellular matrix (ECM) into signaling that can affect the nucleus. One pathway by which such nuclear mechanotransduction occurs is a signaling axis that begins with integrin-ECM bonds and continues through a cascade of chemical reactions and structural changes that lead to nuclear translocation of YAP/TAZ. This signaling axis is self-reinforcing, with stiff ECM promoting integrin binding and thus facilitating polymerization and tension in the cytoskeletal contractile apparatus, which can compress nuclei, open nuclear pore channels, and enhance nuclear accumulation of YAP/TAZ. We previously developed a computational model of this mechanosensing axis for the linear elastic ECM by assuming that there is a linear relationship between the nucleocytoplasmic ratio of YAP/TAZ and nuclear flattening. Here, we extended our previous model to more general ECM behaviors (e.g., viscosity, viscoelasticity, and viscoplasticity) and included detailed YAP/TAZ translocation dynamics based on nuclear deformation. This model was predictive of diverse mechanosensing responses in a broad range of cells. Results support the hypothesis that diverse mechanosensing phenomena across many cell types arise from a simple, unified set of mechanosensing pathways.


Subject(s)
Adaptor Proteins, Signal Transducing , Transcription Factors , Transcription Factors/metabolism , Mechanotransduction, Cellular , YAP-Signaling Proteins , Extracellular Matrix/metabolism , Integrins/metabolism
19.
Adv Healthc Mater ; 12(1): e2201594, 2023 01.
Article in English | MEDLINE | ID: mdl-36398536

ABSTRACT

Brain lesions can arise from traumatic brain injury, infection, and craniotomy. Although injectable hydrogels show promise for promoting healing of lesions and health of surrounding tissue, enabling cellular ingrowth and restoring neural tissue continue to be challenging. It is hypothesized that these challenges arise in part from the mismatch of composition, stiffness, and viscoelasticity between the hydrogel and the brain parenchyma, and this hypothesis is tested by developing and evaluating a self-healing hydrogel that not only mimics the composition, but also the stiffness and viscoelasticity of native brain parenchyma. The hydrogel is crosslinked by dynamic boronate ester bonds between phenylboronic acid grafted hyaluronic acid (HA-PBA) and dopamine grafted gelatin (Gel-Dopa). This HA-PBA/Gel-Dopa hydrogel could be injected into a lesion cavity in a shear-thinning manner with rapid hemostasis, high tissue adhesion, and efficient self-healing. In an in vivo mouse model of brain lesions, the multi-functional injectable hydrogel is found to support neural cell infiltration, decrease astrogliosis and glial scars, and close the lesions. The results suggest a role for extracellular matrix-mimicking viscoelasticity in brain lesion healing, and motivate additional experimentation in larger animals as the technology progresses toward potential application in humans.


Subject(s)
Hydrogels , Wound Healing , Mice , Humans , Animals , Hydrogels/pharmacology , Hydrogels/chemistry , Hyaluronic Acid/pharmacology , Hyaluronic Acid/chemistry , Brain , Extracellular Matrix
20.
Small ; 19(1): e2204498, 2023 01.
Article in English | MEDLINE | ID: mdl-36228093

ABSTRACT

Soft-hard tissue interfaces in nature present a diversity of hierarchical transitions in composition and structure to address the challenge of stress concentrations that would otherwise arise at their interface. The translation of these into engineered materials holds promise for improved function of biomedical interfaces. Here, soft-hard tissue interfaces found in the body in health and disease, and the application of the diverse, functionally graded, and hierarchical structures that they present to bioinspired engineering materials are reviewed. A range of such bioinspired engineering materials and associated manufacturing technologies that are on the horizon in interfacial tissue engineering, hydrogel bioadhesion at the interfaces, and healthcare and medical devices are described.


Subject(s)
Biomimetic Materials , Tissue Engineering
SELECTION OF CITATIONS