Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
3.
J Clin Microbiol ; 47(9): 2931-6, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19605574

ABSTRACT

Assessment of the viral load in hepatitis C virus (HCV) genotype 1-infected patients is critical before, during, and after antiviral therapy. In patients achieving a rapid virological response at week 4 of treatment, the viral load at the baseline is considered a predictive criterion of a sustained virological response 24 weeks after the discontinuation of treatment. A >or=2-log(10) drop in the viral load at week 12 of treatment (early virological response) triggers the continuation of therapy. We organized a multicenter study (MS) for diagnostic laboratories involved in the quantification of HCV RNA. Commercial assays, including two based on real-time reverse transcription-PCR (TaqMan system), and in-house methods, were used by the 61 participants. The overall reproducibility of the commercial quantitative nucleic acid amplification techniques (qNAT) was acceptable. As the intermethod variability among commercial qNAT for HCV RNA was still present, the manufacturers of these test kits should join efforts to harmonize the means of quantification of HCV RNA. This study also shows that caution should be exercised when the baseline viral load is evaluated and when the 2-log(10) reduction after 12 weeks of therapy is interpreted. Finally, this MS confirms the higher sensitivity of the commercial qNAT based on the TaqMan system, making them the elective assays for the monitoring of therapy.


Subject(s)
Hepacivirus/isolation & purification , Hepatitis C/virology , RNA, Viral/blood , Reverse Transcriptase Polymerase Chain Reaction/methods , Viral Load/methods , Genotype , Hepacivirus/genetics , Humans , Molecular Diagnostic Techniques/methods , RNA, Viral/genetics , Reagent Kits, Diagnostic , Reproducibility of Results , Sensitivity and Specificity
4.
Ann Ist Super Sanita ; 43(1): 69-76, 2007.
Article in English | MEDLINE | ID: mdl-17536156

ABSTRACT

We organised a collaborative study to calibrate three new ISS reference preparations (ISS: Istituto Superiore di Sanità), one for HCV RNA, one for HIV RNA and one for HBV DNA, to be used for nucleic acid amplification techniques (NAT) in blood testing. Serial dilution of the ISS reference preparations and the respective international standards were tested in different days by each participating laboratory using two commercial NAT assays. Data were collected by the ISS for statistical analysis. Based on the mean potency of the HCV RNA and HIV RNA preparations, calculated from the results provided by the 12 participating laboratories, a definitive concentrations of 5700 IU/mL and 4000 IU/mL, respectively, were assigned to the reference materials. On the contrary, it was not possible to obtain a consensus titre for the HBV DNA reference material. These new Italian reference preparations (HCV RNA ISS/1005 and HIV RNA ISS/1005) calibrated against the respective international standards are available free of charge to any laboratory upon request.


Subject(s)
DNA, Viral/standards , HIV/genetics , Hepacivirus/genetics , Hepatitis B virus/genetics , Nucleic Acid Amplification Techniques/standards , RNA, Viral/standards , Virology/standards , Calibration , Internationality , Italy , Reference Standards
5.
J Clin Virol ; 30(4): 313-9, 2004 Aug.
Article in English | MEDLINE | ID: mdl-15163420

ABSTRACT

BACKGROUND: The importance of the standardisation of nucleic acid amplification technology (NAT) assays for the detection of hepatitis C virus RNA is well known today, as many studies carried out in different European countries attest. The results of a previous study performed in Italy (J. Clin. Virol. 1 (2003) 83) by the Italian Society of Clinical Microbiology (AMCLI) showed that the use of external reference standards and of multicentre collaborative studies significantly improves laboratory performance for the qualitative evaluation of HCV RNA. OBJECTIVES: the AMCLI organised a new study on the standardisation of both the qualitative and the quantitative evaluation of HCV RNA with NAT in order to improve the implementation of the diagnostic methods for HCV RNA detection. STUDY DESIGN: seventeen diagnostic centres of major Italian Hospitals participated in this quality control study. The study consisted of testing three panels, each made up of 10 coded samples including negative and positive samples. Positive samples contained four levels of HCV RNA (genotype 1). RESULTS AND CONCLUSION: Seven out of 510 qualitative results obtained were incorrect (1.4%), two false negative and five false positive. The results gave a sensitivity of 99.5% and a specificity of 95.8%. Regarding quantitative tests, the geometric mean (GM) and standard deviation (S.D.) could be calculated only for the three highest HCV RNA levels. The percentage of results within the range of GM +/- 0.5 log(10) varied from 91% to 100%. Some laboratories had some difficulty in the exact quantification of the lowest (3.00 log IU/ml) as well as of the highest viral levels (6.35 log IU/ml) values, very near to the limits of the dynamic range of the assays. The comparison of the results of this study with that previously carried out one confirms that a regular participation in external quality assessment (EQA) assures the achievement of a high proficiency level in the diagnosis of HCV infection.


Subject(s)
Hepacivirus/isolation & purification , Hepatitis C/diagnosis , Laboratories , Nucleic Acid Amplification Techniques/methods , RNA, Viral/blood , Hepatitis C/virology , Humans , Italy , Nucleic Acid Amplification Techniques/standards , Polymerase Chain Reaction/methods , Quality Control , Reagent Kits, Diagnostic , Reference Standards , Reproducibility of Results , Sensitivity and Specificity
7.
Ann Ist Super Sanita ; 39(2): 183-7, 2003.
Article in English | MEDLINE | ID: mdl-14587216

ABSTRACT

We organised a collaborative study to calibrate a new Italian reference preparation for HCV RNA, the ISS 0102 reagent, to be used for plasma pools testing. This preparation will replace the previous one, the ISS 0498 reagent, as we are running short of it. The ISS 0102 reagent was obtained by appropriately diluting an HCV RNA-positive donation. Every participant in the collaborative study received four coded panels, each consisting of 5 semi-logarithmic dilutions of the international standard, 5 semi-logarithmic dilutions of the ISS 0102, and 2 samples of a negative plasma pool. Based on the results provided by the 22 participating laboratories, an HCV RNA concentration of 4500 IU/ml was assigned to the reference material. This preparation is available free of charge to any laboratory upon request.


Subject(s)
Hepatitis C/genetics , RNA, Viral/standards , Calibration , Indicators and Reagents , International Cooperation , Italy , Reference Standards
8.
J Clin Microbiol ; 40(12): 4765-7, 2002 Dec.
Article in English | MEDLINE | ID: mdl-12454191

ABSTRACT

An evaluation of the AMPLICOR hepatitis C virus (HCV) monitor test, version 2.0 (Roche Diagnostics), was carried out to investigate whether this test overestimates the HCV RNA content of reference preparations. Satisfactory accuracy was observed when the World Health Organization HCV international standard was included in the assay and a modified formula was used to calculate the viral content.


Subject(s)
Hepacivirus/isolation & purification , Hepatitis C/diagnosis , Polymerase Chain Reaction/methods , RNA, Viral/standards , Reagent Kits, Diagnostic , Viral Load/standards , Hepatitis C/virology , Humans , RNA, Viral/blood , Reference Standards
SELECTION OF CITATIONS
SEARCH DETAIL
...