Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Scr Mater ; 120(2016): 19-22, 2016 Jul 15.
Article in English | MEDLINE | ID: mdl-27325910

ABSTRACT

The pressure induced phase transitions of crystalline Si films were studied in situ under a Berkovich probe using a Raman spectroscopy-enhanced instrumented indentation technique. The observations suggested strain and time as important parameters in the nucleation and growth of high-pressure phases and, in contrast to earlier reports, indicate that pressure release is not a precondition for transformation to high pressure phases.

2.
Ultramicroscopy ; 163: 75-86, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26939030

ABSTRACT

The accuracy of electron backscatter diffraction (EBSD) and confocal Raman microscopy (CRM) for small-scale strain mapping are assessed using the multi-axial strain field surrounding a wedge indentation in Si as a test vehicle. The strain field is modeled using finite element analysis (FEA) that is adapted to the near-indentation surface profile measured by atomic force microscopy (AFM). The assessment consists of (1) direct experimental comparisons of strain and deformation and (2) comparisons in which the modeled strain field is used as an intermediate step. Direct experimental methods (1) consist of comparisons of surface elevation and gradient measured by AFM and EBSD and of Raman shifts measured and predicted by CRM and EBSD, respectively. Comparisons that utilize the combined FEA-AFM model (2) consist of predictions of distortion, strain, and rotation for comparison with EBSD measurements and predictions of Raman shift for comparison with CRM measurements. For both EBSD and CRM, convolution of measurements in depth-varying strain fields is considered. The interconnected comparisons suggest that EBSD was able to provide an accurate assessment of the wedge indentation deformation field to within the precision of the measurements, approximately 2×10(-4) in strain. CRM was similarly precise, but was limited in accuracy to several times this value.

3.
Rev Sci Instrum ; 84(11): 113706, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24289403

ABSTRACT

There are many atomic force microscopy (AFM) applications that rely on quantifying the force between the AFM cantilever tip and the sample. The AFM does not explicitly measure force, however, so in such cases knowledge of the cantilever stiffness is required. In most cases, the forces of interest are very small, thus compliant cantilevers are used. A number of methods have been developed that are well suited to measuring low stiffness values. However, in some cases a cantilever with much greater stiffness is required. Thus, a direct, traceable method for calibrating very stiff (approximately 200 N/m) cantilevers is presented here. The method uses an instrumented and calibrated nanoindenter to determine the stiffness of a reference cantilever. This reference cantilever is then used to measure the stiffness of a number of AFM test cantilevers. This method is shown to have much smaller uncertainty than previously proposed methods. An example application to fracture testing of nanoscale silicon beam specimens is included.

4.
Am J Phys Anthropol ; 148(2): 171-7, 2012 Jun.
Article in English | MEDLINE | ID: mdl-22610893

ABSTRACT

Primate teeth adapt to the physical properties of foods in a variety of ways including changes in occlusal morphology, enamel thickness, and overall size. We conducted a comparative study of extant primates to examine whether their teeth also adapt to foods through variation in the mechanical properties of the enamel. Nanoindentation techniques were used to map profiles of elastic modulus and hardness across tooth sections from the enamel-dentin junction to the outer enamel surface in a broad sample of primates including apes, Old World monkeys, New World monkeys, and lemurs. The measured data profiles feature considerable overlap among species, indicating a high degree of commonality in mechanical properties. These results suggest that differences in the load-bearing capacity of primate molar teeth are more a function of morphology-particularly tooth size and enamel thickness-than of underlying mechanical properties.


Subject(s)
Dental Enamel/chemistry , Dental Enamel/physiology , Diet , Primates/anatomy & histology , Primates/physiology , Adaptation, Physiological , Animals , Elastic Modulus , Hardness , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...