Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Interact Cardiovasc Thorac Surg ; 25(4): 513-519, 2017 10 01.
Article in English | MEDLINE | ID: mdl-28962497

ABSTRACT

OBJECTIVES: Systolic anterior motion (SAM) can be an insidious complication after mitral repair. Predicting SAM represents a challenge, even for very experienced mitral valve surgeons. The goal of this pilot work was to illustrate for the first time, a computational software able to calculate and prevent SAM during mitral repair. METHODS: Using MATLAB graphical user interface, a clinical software to predict SAM, we tested the performances of the software on 136 patients with degenerative mitral valves undergoing repair with standard techniques. A combination of 6 key echocardiographic parameters was used to calculate the SAM risk score. The discriminative performance of the model was assessed by the area under the receiver-operating characteristic curve. The receiver-operating characteristic was used to divide patients into low, medium and high risk for SAM. Simulation of virtual mitral repair (posterior leaflet resection and mitral ring annuloplasty) was also tested to reduce the risk of SAM. RESULTS: The incidence of SAM was 8.1%; 73% were detected as high risk by the software. The area under the receiver-operating characteristic model discriminant performance was 0.87 (95% confidence interval: 0.78-0.95). Simulating a posterior leaflet resection with the leaflet length fixed at 15 mm, the estimated SAM risk was updated, and all patients were then classified at low risk. CONCLUSIONS: This software is the first computational model designed to predict SAM during mitral repair to show excellent discrimination. This software has the potential to predict SAM risk preoperatively and, after a virtual step-by-step mitral repair simulation, depending on the technique adopted, to always achieve a low-risk SAM profile.


Subject(s)
Cardiac Surgical Procedures , Computer Simulation , Heart Ventricles/physiopathology , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Ventricular Function/physiology , Echocardiography, Transesophageal , Female , Heart Ventricles/diagnostic imaging , Humans , Male , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/physiopathology , Pilot Projects , Postoperative Period , ROC Curve , Systole
2.
Article in English | MEDLINE | ID: mdl-29300071

ABSTRACT

Mitral valve prosthetic ring annuloplasty represents a key milestone in the history of mitral valve repair, delivering restoration of annular shape and size. Increased leaflet coaptation, together with significant reduction in stress on sutures, has ensured predictability and immediate stability for valve repair, both of which were lacking with previous techniques. Long-term durability of repair seems to be positively affected by placement of an annuloplasty ring, and by following the well-established, standardized approach described in our tutorial, this procedure can be performed with a very low surgical risk.


Subject(s)
Heart Valve Diseases/surgery , Mitral Valve Annuloplasty/methods , Mitral Valve/surgery , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...