Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 19(6): e0304115, 2024.
Article in English | MEDLINE | ID: mdl-38861500

ABSTRACT

There are currently no established biomarkers for predicting the therapeutic effectiveness of Vagus Nerve Stimulation (VNS). Given that neural desynchronization is a pivotal mechanism underlying VNS action, EEG synchronization measures could potentially serve as predictive biomarkers of VNS response. Notably, an increased brain synchronization in delta band has been observed during sleep-potentially due to an activation of thalamocortical circuitry, and interictal epileptiform discharges are more frequently observed during sleep. Therefore, investigation of EEG synchronization metrics during sleep could provide a valuable insight into the excitatory-inhibitory balance in a pro-epileptogenic state, that could be pathological in patients exhibiting a poor response to VNS. A 19-channel-standard EEG system was used to collect data from 38 individuals with Drug-Resistant Epilepsy (DRE) who were candidates for VNS implantation. An EEG synchronization metric-the Weighted Phase Lag Index (wPLI)-was extracted before VNS implantation and compared between sleep and wakefulness, and between responders (R) and non-responders (NR). In the delta band, a higher wPLI was found during wakefulness compared to sleep in NR only. However, in this band, no synchronization difference in any state was found between R and NR. During sleep and within the alpha band, a negative correlation was found between wPLI and the percentage of seizure reduction after VNS implantation. Overall, our results suggest that patients exhibiting a poor VNS efficacy may present a more pathological thalamocortical circuitry before VNS implantation. EEG synchronization measures could provide interesting insights into the prerequisites for responding to VNS, in order to avoid unnecessary implantations in patients showing a poor therapeutic efficacy.


Subject(s)
Drug Resistant Epilepsy , Electroencephalography , Vagus Nerve Stimulation , Humans , Vagus Nerve Stimulation/methods , Male , Female , Adult , Drug Resistant Epilepsy/therapy , Drug Resistant Epilepsy/physiopathology , Retrospective Studies , Young Adult , Biomarkers , Sleep/physiology , Adolescent , Middle Aged , Electroencephalography Phase Synchronization , Treatment Outcome , Wakefulness/physiology
2.
Biomedicines ; 12(3)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38540170

ABSTRACT

This study investigates the dose-dependent EEG effects of Vagus Nerve Stimulation (VNS) in patients with drug-resistant epilepsy. This research examines how varying VNS intensities impacts EEG power spectrum and synchronization in a cohort of 28 patients. Patients were categorized into responders, partial-responders, and non-responders based on seizure frequency reduction. The methods involved EEG recordings at incremental VNS intensities, followed by spectral and synchronization analysis. The results reveal significant changes in EEG power, particularly in the delta and beta bands across different intensities. Notably, responders exhibited distinct EEG changes compared to non-responders. Our study has found that VNS intensity significantly influences EEG power topographic allocation and brain desynchronization, suggesting the potential use of acute dose-dependent effects to personalized VNS therapy in the treatment of epilepsy. The findings underscore the importance of individualized VNS dosing for optimizing therapeutic outcomes and highlight the use of EEG metrics as an effective tool for monitoring and adjusting VNS parameters. These insights offer a new avenue for developing individualized VNS therapy strategies, enhancing treatment efficacy in epilepsy.

3.
Epilepsy Behav ; 143: 109229, 2023 06.
Article in English | MEDLINE | ID: mdl-37148703

ABSTRACT

OBJECTIVE: During the presurgical evaluation, manual electrical source imaging (ESI) provides clinically useful information in one-third of the patients but it is time-consuming and requires specific expertise. This prospective study aims to assess the clinical added value of a fully automated ESI analysis in a cohort of patients with MRI-negative epilepsy and describe its diagnostic performance, by evaluating sublobar concordance with stereo-electroencephalography (SEEG) results and surgical resection and outcome. METHODS: All consecutive patients referred to the Center for Refractory Epilepsy (CRE) of St-Luc University Hospital (Brussels, Belgium) for presurgical evaluation between 15/01/2019 and 31/12/2020 meeting the inclusion criteria, were recruited to the study. Interictal ESI was realized on low-density long-term EEG monitoring (LD-ESI) and, whenever available, high-density EEG (HD-ESI), using a fully automated analysis (Epilog PreOp, Epilog NV, Ghent, Belgium). The multidisciplinary team (MDT) was asked to formulate hypotheses about the epileptogenic zone (EZ) location at sublobar level and make a decision on further management for each patient at two distinct moments: i) blinded to ESI and ii) after the presentation and clinical interpretation of ESI. Results leading to a change in clinical management were considered contributive. Patients were followed up to assess whether these changes lead to concordant results on stereo-EEG (SEEG) or successful epilepsy surgery. RESULTS: Data from all included 29 patients were analyzed. ESI led to a change in the management plan in 12/29 patients (41%). In 9/12 (75%), modifications were related to a change in the plan of the invasive recording. In 8/9 patients, invasive recording was performed. In 6/8 (75%), the intracranial EEG recording confirmed the localization of the ESI at a sublobar level. So far, 5/12 patients, for whom the management plan was changed after ESI, were operated on and have at least one-year postoperative follow-up. In all cases, the EZ identified by ESI was included in the resection zone. Among these patients, 4/5 (80%) are seizure-free (ILAE 1) and one patient experienced a seizure reduction of more than 50% (ILAE 4). CONCLUSIONS: In this single-center prospective study, we demonstrated the added value of automated ESI in the presurgical evaluation of MRI-negative cases, especially in helping to plan the implantation of depth electrodes for SEEG, provided that ESI results are integrated into the whole multimodal evaluation and clinically interpreted.


Subject(s)
Drug Resistant Epilepsy , Epilepsy , Humans , Prospective Studies , Epilepsy/diagnostic imaging , Epilepsy/surgery , Magnetic Resonance Imaging/methods , Electroencephalography/methods , Electrocorticography , Drug Resistant Epilepsy/diagnostic imaging , Drug Resistant Epilepsy/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...