1.
J Microsc ; 274(1): 13-22, 2019 04.
Article in English | MEDLINE | ID: mdl-30648740

ABSTRACT

Fiducial markers are used in correlated light and electron microscopy (CLEM) to enable accurate overlaying of fluorescence and electron microscopy images. Currently used fiducial markers, e.g. dye-labelled nanoparticles and quantum dots, suffer from irreversible quenching of the luminescence after electron beam exposure. This limits their use in CLEM, since samples have to be studied with light microscopy before the sample can be studied with electron microscopy. Robust fiducial markers, i.e. luminescent labels that can (partially) withstand electron bombardment, are interesting because of the recent development of integrated CLEM microscopes. In addition, nonintegrated CLEM setups may benefit from such fiducial markers. Such markers would allow switching back from EM to LM and are not available yet. Here, we investigate the robustness of various luminescent nanoparticles (NPs) that have good contrast in electron microscopy; 130 nm gold-core rhodamine B-labelled silica particles, 15 nm CdSe/CdS/ZnS core-shell-shell quantum dots (QDs) and 230 nm Y2 O3 :Eu3+ particles. Robustness is studied by measuring the luminescence of (single) NPs after various cycles of electron beam exposure. The gold-core rhodamine B-labelled silica NPs and QDs are quenched after a single exposure to 60 ke-  nm-2 with an energy of 120 keV, while Y2 O3 :Eu3+ NPs are robust and still show luminescence after five doses of 60 ke- nm-2 . In addition, the luminescence intensity of Y2 O3 :Eu3+ NPs is investigated as function of electron dose for various electron fluxes. The luminescence intensity initially drops to a constant value well above the single particle detection limit. The intensity loss does not depend on the electron flux, but on the total electron dose. The results indicate that Y2 O3 :Eu3+ NPs are promising as robust fiducial marker in CLEM. LAY DESCRIPTION: Luminescent particles are used as fiducial markers in correlative light and electron microscopy (CLEM) to enable accurate overlaying of fluorescence and electron microscopy images. The currently used fiducial markers, e.g. dyes and quantum dots, loose their luminescence after exposure to the electron beam of the electron microscope. This limits their use in CLEM, since samples have to be studied with light microscopy before the sample can be studied with electron microscopy. Robust fiducial markers, i.e. luminescent labels that can withstand electron exposure, are interesting because of recent developments in integrated CLEM microscopes. Also nonintegrated CLEM setups may benefit from such fiducial markers. Such markers would allow for switching back to fluorescence imaging after the recording of electron microscopy imaging and are not available yet. Here, we investigate the robustness of various luminescent nanoparticles (NPs) that have good contrast in electron microscopy; dye-labelled silica particles, quantum dots and lanthanide-doped inorganic particles. Robustness is studied by measuring the luminescence of (single) NPs after various cycles of electron beam exposure. The dye-labelled silica NPs and QDs are quenched after a single exposure to 60 ke- nm-2 with an energy of 120 keV, while lanthanide-doped inorganic NPs are robust and still show luminescence after five doses of 60 ke- nm-2 . In addition, the luminescence intensity of lanthanide-doped inorganic NPs is investigated as function of electron dose for various electron fluxes. The luminescence intensity initially drops to a constant value well above the single particle detection limit. The intensity loss does not depend on the electron flux, but on the total electron dose. The results indicate that lanthanide-doped NPs are promising as robust fiducial marker in CLEM.

2.
Opt Express ; 22(8): 9715-33, 2014 Apr 21.
Article in English | MEDLINE | ID: mdl-24787857

ABSTRACT

Deep imaging in turbid media such as biological tissue is challenging due to scattering and optical aberrations. Adaptive optics has the potential to compensate the tissue aberrations. We present a wavefront sensing scheme for multi-photon scanning microscopes using the pulsed, near-infrared light reflected back from the sample utilising coherence gating and a confocal pinhole to isolate the light from a layer of interest. By interfering the back-reflected light with a tilted reference beam, we create a fringe pattern with a known spatial carrier frequency in an image of the back-aperture plane of the microscope objective. The wavefront aberrations distort this fringe pattern and thereby imprint themselves at the carrier frequency, which allows us to separate the aberrations in the Fourier domain from low spatial frequency noise. A Fourier analysis of the modulated fringes combined with a virtual Shack-Hartmann sensor for smoothing yields a modal representation of the wavefront suitable for correction. We show results with this method correcting both DM-induced and sample-induced aberrations in rat tail collagen fibres as well as a Hoechst-stained MCF-7 spheroid of cancer cells.


Subject(s)
Light , Microscopy/instrumentation , Optics and Photonics , Photons , Animals , Fourier Analysis , Rats
3.
Nanotechnology ; 24(31): 315202, 2013 Aug 09.
Article in English | MEDLINE | ID: mdl-23851583

ABSTRACT

Dynamical control of the luminescence of quantum dots is highly important for technology in the field of telecommunication, displays, and photovoltaics. In this work we use an a-Si:H solar cell structure in which CdSe quantum dots are sandwiched. By applying a positive potential over the device, charge carriers generated in the quantum dots are transported to the a-Si:H layer and transformed into electrical energy, changing the luminescence intensity with a switching time lower than 60 ms. This is a promising new step towards using quantum dots in optical switching devices.

4.
J Struct Biol ; 181(3): 283-90, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23261400

ABSTRACT

Correlative light and electron microscopy is an increasingly popular technique to study complex biological systems at various levels of resolution. Fluorescence microscopy can be employed to scan large areas to localize regions of interest which are then analyzed by electron microscopy to obtain morphological and structural information from a selected field of view at nm-scale resolution. Previously, an integrated approach to room temperature correlative microscopy was described. Combined use of light and electron microscopy within one instrument greatly simplifies sample handling, avoids cumbersome experimental overheads, simplifies navigation between the two modalities, and improves the success rate of image correlation. Here, an integrated approach for correlative microscopy under cryogenic conditions is presented. Its advantages over the room temperature approach include safeguarding the native hydrated state of the biological specimen, preservation of the fluorescence signal without risk of quenching due to heavy atom stains, and reduced photo bleaching. The potential of cryo integrated light and electron microscopy is demonstrated for the detection of viable bacteria, the study of in vitro polymerized microtubules, the localization of mitochondria in mouse embryonic fibroblasts, and for a search into virus-induced intracellular membrane modifications within mammalian cells.


Subject(s)
Cryoelectron Microscopy/methods , Freezing , Microscopy, Electron/methods , Specimen Handling/methods , Acinetobacter baumannii , Animals , Chlorocebus aethiops , Fluorescence , Microscopy, Fluorescence , Microtubules , Vero Cells
5.
J Microsc ; 244(3): 248-58, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21933184

ABSTRACT

Fluorescence lifetime imaging is a versatile tool that permits mapping the biochemical environment in the cell. Among various fluorescence lifetime imaging techniques, time-correlated single photon counting and time-gating methods have been demonstrated to be very efficient and robust for the imaging of biological specimens. Recently, the phasor representation of lifetime images became popular because it provides an intuitive graphical view of the fluorescence lifetime content of the images and, when used for global analysis, significantly improves the overall S/N of lifetime analysis. Compared to time-correlated single photon counting, time gating methods can provide higher count rates (∼10 MHz) but at the cost of truncating and under sampling the decay curve due to the limited number of gates commonly used. These limitations also complicate the implementation of the phasor analysis for time-gated data. In this work, we propose and validate a theoretical framework that overcomes these problems. This modified approach is tested on both simulated lifetime images and on cells. We demonstrate that this method is able to retrieve two lifetimes from time gating data that cannot be resolved using standard (non-global) fitting techniques. The new approach increases the information that can be obtained from typical measurements and simplifies the analysis of fluorescence lifetime imaging data.


Subject(s)
Cytological Techniques/methods , Image Processing, Computer-Assisted/methods , Microscopy, Fluorescence/methods , Animals , COS Cells , Chlorocebus aethiops
6.
Opt Express ; 14(10): 4395-402, 2006 May 15.
Article in English | MEDLINE | ID: mdl-19516591

ABSTRACT

We report on two-photon autofluorescence and second harmonic spectral imaging of live mouse tissues. The use of a high sensitivity detector and ultraviolet optics allowed us to record razor-sharp deep-tissue spectral images of weak autofluorescence and short-wavelength second harmonic generation by mouse skin. Real-color image representation combined with depth-resolved spectral analysis enabled us to identify tissue structures. The results show that linking nonlinear deep-tissue imaging microscopy with autofluorescence spectroscopy has the potential to provide important information for the diagnosis of skin tissues.

7.
J Biomed Opt ; 9(6): 1230-7, 2004.
Article in English | MEDLINE | ID: mdl-15568944

ABSTRACT

A fast fluorescence lifetime imaging (FLIM) system is developed that can acquire images at a rate of hundreds of frames per second. The FLIM system is based on a wide-field microscope equipped with a time-gated intensified CCD detector and a pulsed laser. The time-gated detector acquires the signals from two time gates simultaneously and is therefore insensitive to movements of the specimen and photo-bleaching. The system is well suited for quantitative biological FLIM experiments and its performance is evaluated in calcium imaging experiments on beating neonatal rat myocytes. Several calcium sensitive dyes are characterized and tested for their suitability for fast FLIM experiments: Oregon Green Bapta-1 (OGB1), Oregon Green Bapta-2 (OGB2), and Oregon Green Bapta-5N (OGB5N). Overall the sensitivity range of these dyes is shifted to low calcium concentrations when used as lifetime dyes. OGB1 and OGB2 behave very similarly and can be used for FLIM-based calcium imaging in the range 1 to approximately 500 nM and OGB5N can be used up to 3 microM. The fast FLIM experiments on the myocytes could be carried out at a 100-Hz frame rate. During the beating of the myocytes a lifetime change of about 20% is observed. From the lifetime images a rest calcium level of about 65 nM is found.


Subject(s)
Algorithms , Calcium/metabolism , Image Enhancement/methods , Microscopy, Confocal/methods , Microscopy, Fluorescence/methods , Muscle Cells/cytology , Muscle Cells/metabolism , Animals , Animals, Newborn , Cells, Cultured , Feasibility Studies , Image Interpretation, Computer-Assisted/methods , Microscopy, Video/methods , Rats , Reproducibility of Results , Sensitivity and Specificity , Subtraction Technique
8.
J Microsc ; 206(Pt 3): 218-24, 2002 Jun.
Article in English | MEDLINE | ID: mdl-12067366

ABSTRACT

In this paper a detailed discussion is presented of the factors that affect the fluorescence lifetime imaging performance of a scanning microscope equipped with a single photon counting based, two- to eight-channel, time-gated detection system. In particular we discuss the sensitivity, lifetime resolution, acquisition speed, and the shortest lifetimes that can be measured. Detection systems equipped with four to eight time-gates are significantly more sensitive than the two time-gate system. Only minor sensitivity differences were found between systems with four or more time-gates. Experiments confirm that the lifetime resolution is dominated by photon statistics. The time response of the detector determines the shortest lifetimes that can be resolved; about 25 ps for fast MCP-PMTs and 300-400 ps for other detectors. The maximum count rate of fast MCP-PMTs, however, is 10-100 times lower than that of fast PMTs. Therefore, the acquisition speed with MCP-PMT based systems is limited. With a fast PMT operated close to its maximum count rate we were able to record a fluorescence lifetime image of a beating myocyte in less than one second.


Subject(s)
Microscopy, Electron, Scanning/instrumentation , Animals , Fluorescence , Microscopy, Electron, Scanning/methods , Muscle Cells/ultrastructure , Photons , Rats
9.
Biophys J ; 81(1): 538-46, 2001 Jul.
Article in English | MEDLINE | ID: mdl-11423435

ABSTRACT

Two-photon excitation, time-resolved fluorescence microscopy was used to investigate the fluorescence quenching mechanisms in aggregates of light-harvesting chlorophyll a/b pigment protein complexes of photosystem II from green plants (LHCII). Time-gated microscopy images show the presence of large heterogeneity in fluorescence lifetimes not only for different LHCII aggregates, but also within a single aggregate. Thus, the fluorescence decay traces obtained from macroscopic measurements reflect an average over a large distribution of local fluorescence kinetics. This opens the possibility to resolve spatially different structural/functional units in chloroplasts and other heterogeneous photosynthetic systems in vivo, and gives the opportunity to investigate individually the excited states dynamics of each unit. We show that the lifetime distribution is sensitive to the concentration of quenchers contained in the system. Triplets, which are generated at high pulse repetition rates of excitation (>1 MHz), preferentially quench domains with initially shorter fluorescence lifetimes. This proves our previous prediction from singlet-singlet annihilation investigations (Barzda, V., V. Gulbinas, R. Kananavicius, V. Cervinskas, H. van Amerongen, R. van Grondelle, and L. Valkunas. 2001. Biophys. J. 80:2409-2421) that shorter fluorescence lifetimes originate from larger domains in LHCII aggregates. We found that singlet-singlet annihilation has a strong effect in time-resolved fluorescence microscopy of connective systems and has to be taken into consideration. Despite that, clear differences in fluorescence decays can be detected that can also qualitatively be understood.


Subject(s)
Microscopy, Fluorescence/methods , Photosynthetic Reaction Center Complex Proteins/chemistry , Photosynthetic Reaction Center Complex Proteins/metabolism , Fluorescence , Half-Life , Kinetics , Light-Harvesting Protein Complexes , Pisum sativum , Photosystem II Protein Complex , Protein Structure, Quaternary
10.
Microsc Res Tech ; 47(3): 206-9, 1999 Nov 01.
Article in English | MEDLINE | ID: mdl-10544335

ABSTRACT

The in-depth imaging properties of two-photon excitation microscopy were investigated and compared with those of confocal microscopy. Confocal imaging enabled the recording of images from dental biofilm down to a depth of 40 microm, while two-photon excitation images could be recorded at depths greater than 100 microm. Two-photon excitation point spread functions (PSFs) were recorded at depths ranging from 0 to 90 microm depth using 220-nm diameter fluorescent beads immersed in water. PSFs were measured using both a high numerical aperture oil immersion objective and a water immersion objective. The experiments carried out using the oil immersion objective showed a rapid degradation of both the axial and lateral resolution due to spherical aberrations. In addition, the detected fluorescence intensity rapidly decreased as a function of depth. The experiments carried out using the water immersion objective showed no significant degradation of both the axial and lateral resolution and the fluorescence intensity.


Subject(s)
Microscopy, Confocal/methods , Microscopy, Fluorescence/methods , Bacteria , Biofilms , Mouth/microbiology , Photons
12.
Appl Environ Microbiol ; 65(8): 3502-11, 1999 Aug.
Article in English | MEDLINE | ID: mdl-10427041

ABSTRACT

Deep microbial biofilms are a major problem in many industrial, environmental, and medical settings. Novel approaches are needed to understand the structure and metabolism of these biofilms. Two-photon excitation microscopy (TPE) and conventional confocal laser scanning microscopy (CLSM) were compared quantitatively for the ability to visualize bacteria within deep in vitro biofilms. pH gradients within these biofilms were determined by fluorescence lifetime imaging, together with TPE. A constant-depth film fermentor (CDFF) was inoculated for 8 h at 50 ml. h(-1) with a defined mixed culture of 10 species of bacteria grown in continuous culture. Biofilms of fixed depths were developed in the CDFF for 10 or 11 days. The microbial compositions of the biofilms were determined by using viable counts on selective and nonselective agar media; diverse mixed-culture biofilms developed, including aerobic, facultative, and anaerobic species. TPE was able to record images four times deeper than CLSM. Importantly, in contrast to CLSM images, TPE images recorded deep within the biofilm showed no loss of contrast. The pH within the biofilms was measured directly by means of fluorescence lifetime imaging; the fluorescence decay of carboxyfluorescein was correlated with biofilm pH and was used to construct a calibration curve. pH gradients were detectable, in both the lateral and axial directions, in steady-state biofilms. When biofilms were overlaid with 14 mM sucrose for 1 h, distinct pH gradients developed. Microcolonies with pH values of below pH 3.0 were visible, in some cases adjacent to areas with a much higher pH (>5.0). TPE allowed resolution of images at significantly greater depths (as deep as 140 microm) than were possible with CLSM. Fluorescence lifetime imaging allowed the in situ, real-time imaging of pH and the detection of sharp gradients of pH within microbial biofilms.


Subject(s)
Biofilms , Microscopy, Fluorescence/methods , Colony Count, Microbial , Evaluation Studies as Topic , Humans , Hydrogen-Ion Concentration , Microscopy, Confocal , Microscopy, Fluorescence/instrumentation , Photons , Sucrose
13.
Appl Opt ; 38(28): 5995-6003, 1999 Oct 01.
Article in English | MEDLINE | ID: mdl-18324119

ABSTRACT

The detrimental effects of a refractive-index mismatch on the image formation in a two-photon microscope were investigated. Point-spread functions (PSF's) were recorded with an oil-immersion objective numerical aperture (NA) of 1.3 and a water-immersion objective NA of 1.2 in an aqueous sample at different depths. For the oil-immersion objective the enlargement of the PSF volume with increasing depth yields an axial and a lateral loss in resolution of approximately 380% and 160%, respectively, at a 90-microm depth in the sample. For the water-immersion objective no resolution decrease was found. Measurements on a thick aqueous biofilm sample shows the importance of matching the refractive index between immersion fluid and sample. With a good match, no loss in image resolution is observed.

14.
J Microsc ; 182(Pt 3): 217-24, 1996 Jun.
Article in English | MEDLINE | ID: mdl-8801359

ABSTRACT

A confocal scanning light microscope coupled to the Daresbury Synchrotron Radiation Source is described. The broad spectrum of synchrotron radiation and the application of achromatic quartz/CaF2 optics allows for confocal imaging over the wavelength range 200-700 nm. This includes UV light, which is particularly suitable for high-resolution imaging. The results of test measurements using 290-nm light indicate that a lateral resolution better than 100 nm is obtained. An additional advantage of the white synchrotron radiation is that the excitation wavelength can be chosen to match the absorption band of any fluorescent dye. The availability of UV light for confocal microscopy enables studies of naturally occurring fluorophores. The potential applications of the microscope are illustrated by the real-time imaging of hormone traffic using the naturally occurring oestrogen coumestrol. (The IUPAC name for coumestrol is 3,9-dihydroxy-6H-benzofurol[3,2-c][1]benzo-pyran-6-one (Chem. Abstr. Reg. No. 479-13-0). The trivial name will be used throughout this paper.


Subject(s)
Coumestrol/metabolism , Microscopy, Confocal/methods , Microscopy, Fluorescence/methods , Testis/metabolism , Animals , Biological Transport , Male , Microscopy, Confocal/instrumentation , Microscopy, Fluorescence/instrumentation , Synchrotrons , Ultraviolet Rays
15.
Anal Biochem ; 227(2): 302-8, 1995 May 20.
Article in English | MEDLINE | ID: mdl-7573951

ABSTRACT

The pH-sensitive probe carboxy SNAFL-1 can be used for imaging using ratiometric and fluorescence lifetime techniques. The former method suffers from the drawback that quantitative pH imaging in cells requires a time-consuming and cumbersome calibration procedure. In contrast, straightforward calibrations in buffer suffice for fluorescence lifetime imaging. This is illustrated here by a comparative study of the two techniques under different controlled conditions. The effect of probe concentration, protein concentration, and hydrophobicity, the contents of damaged cells and living cells on the emission ratio, and the fluorescence lifetime of carboxy SNAFL-1 were studied. The results clearly demonstrate that the fluorescence lifetime imaging technique is more convenient than the ratiometric method for pH determination.


Subject(s)
Cells/chemistry , Microscopy, Confocal , Microscopy, Fluorescence/methods , Animals , Buffers , CHO Cells , Calibration , Cricetinae , Hydrogen-Ion Concentration , Proteins/chemistry , Sensitivity and Specificity , Solubility , Tumor Cells, Cultured , Water/chemistry
16.
Contracept Fertil Sex ; 22(10): 618-22, 1994 Oct.
Article in French | MEDLINE | ID: mdl-7804380

ABSTRACT

Effects of epidermal growth factor (EGF) on pH transients in aggregates of Sertoli cells and germinal cells have been investigated with confocal microscopy using a fluorescent pH sensitive indicator. In some Sertoli cells EGF caused a rapid rise in the pH whereas other Sertoli cells did not respond to EGF. Some Sertoli cells showed a delayed response which coincidated with a similar pH change in neighbouring germinal cells. Since isolated germinal cells never showed a pH response after exposure to EGF, we have concluded that some Sertoli cells may communicate with germinal cells via gap junctions.


Subject(s)
Epidermal Growth Factor/pharmacology , Microscopy, Confocal/methods , Seminiferous Epithelium/cytology , Seminiferous Epithelium/drug effects , Animals , Cell Communication , Germ Cells/drug effects , Germ Cells/physiology , Hydrogen-Ion Concentration , Male , Microscopy, Fluorescence , Rats , Seminiferous Epithelium/ultrastructure , Sertoli Cells/drug effects , Sertoli Cells/physiology
17.
Eur Biophys J ; 23(5): 369-78, 1994.
Article in English | MEDLINE | ID: mdl-7835321

ABSTRACT

A fluorescence depolarization study of the orientational distribution of crossbridges in dye-labelled muscle fibres is presented. The characterization of this distribution is important since the rotation of crossbridges is a key element in the theory of muscle contraction. In this study we exploited the advantages of angle-resolved experiments to characterize the principal features of the orientational distribution of the crossbridges in the muscle fibre. The directions of the transition dipole moments in the frame of the dye and the orientation and motion of the dye relative to the crossbridge determined previously were explicitly incorporated into the analysis of the experimental data. This afforded the unequivocal determination of all the second and fourth rank order parameters. Moreover, this additional information provided discrimination between different models for the orientational behaviour of the crossbridges. Our results indicate that no change of orientation takes place upon a transition from rigor to relaxation. The experiments, however, do no rule out a conformational change of the myosin S1 during the transition.


Subject(s)
Models, Biological , Models, Theoretical , Muscle Fibers, Skeletal/physiology , Muscle, Skeletal/physiology , Animals , Fluorescent Dyes , Muscle Contraction , Muscle Fibers, Skeletal/ultrastructure , Muscle, Skeletal/ultrastructure , Naphthalenesulfonates , Rabbits , Scattering, Radiation , Spectrometry, Fluorescence
18.
J Fluoresc ; 4(4): 291-4, 1994 Dec.
Article in English | MEDLINE | ID: mdl-24233601

ABSTRACT

Ca(2+) concentrations in biological cells are widely studied with fluorescent probes. The probes have a high selectivity for free calcium and exhibit marked changes in their photophysical properties upon binding. The differences in the fluorescent lifetime of the probes can now be used as a contrast mechanism for imaging purposes. This technique can be further exploited for the quantitative determination of ion concentrations within the cells. We describe the use of a fast fluorescence lifetime imaging method in combination with a standard confocal laser scanning microscope for the determination of Ca(2+) concentrations in single rat cardiac myocytes using the intensity probe Calcium Green.

19.
J Fluoresc ; 4(4): 323-6, 1994 Dec.
Article in English | MEDLINE | ID: mdl-24233607

ABSTRACT

Angle-resolved fluorescence depolarization (AFD) experiments have been used for over a decade in studies of fluorescent molecules in macroscopically aligned systems such as lipid bilayers and stretched polymer films. The importance of this technique lies in the fact that it affords the determination of both the second- and the fourth-rank order parameters of the orientational distribution of the probe molecules in the sample. Here we apply the technique to the study of the orientational distribution of crossbridges in muscle fibers. This orientational distribution is particularly relevant in muscle research, as crossbridge rotation is commonly regarded to be the driving mechanism in force development. An unfortunate consequence of the fact that the crossbridges have an average orientation of approximately 45(o) relative to the fiber axis is that the values of the second-rank order parameter [Symbol: see text]P 2[Symbol: see text] of the crossbridge distribution are close to 0. Therefore, knowledge of [Symbol: see text]P 4[Symbol: see text] is essential for a reliable reconstruction of the form of the distribution function. AFD of dyelabeled muscle was measured under rigor and relaxation conditions. The results indicate that no significant changes in depolarization take place upon a transition from the rigor to the relaxed state in the muscle and seem not to support the rotating crossbridge model, which postulates a clear change of orientation of the crossbridges.

20.
Eur Biophys J ; 21(4): 263-72, 1992.
Article in English | MEDLINE | ID: mdl-1385106

ABSTRACT

Fluorescence and phosphorescence depolarization techniques can provide information on orientational order and rotational motion of crossbridges in muscle fibres. However the depolarization experiment monitors the orientation and motion of the crossbridges indirectly. The changes in depolarization arise from a change in the orientation of the transition dipoles of the dye attached to the crossbridge. In order to extract the physiologically relevant orientations from the data it is therefore necessary to characterize the orientation of the dye molecule relative to the crossbridge and the orientation of the transition moments in the frame of the dyes. The dyes 1,5-I-AEDANS and eosin-5-maleimide are commonly used for labelling the crossbridge in muscle fibres. The orientations of the absorption and fluorescence emission dipoles of these two dyes in the molecular frame were determined. Angle resolved fluorescence depolarization experiments on the dyes, macroscopically aligned in a stretched polymer matrix of poly vinyl alcohol, were carried out. The data were analyzed in terms of an orientational distribution of the dye molecules in the film and the orientations of the absorption and emission dipoles in the frame of the dye molecule. Experimental data, obtained from a given sample at different excitation wavelengths, were analyzed simultaneously in a global target approach. This leads to a reduction in the number of independent parameters optimized by the non-linear least squares procedure.


Subject(s)
Fluorescent Dyes , Muscles/ultrastructure , Animals , Eosine Yellowish-(YS)/analogs & derivatives , Luminescent Measurements , Mathematics , Models, Theoretical , Naphthalenesulfonates , Spectrometry, Fluorescence/methods