ABSTRACT
The operating principle of innovative interval radon exposure meters INERAD (types IE-2 and IE-4) is described. The major technical features of the both models have been standardized as much as possible. The exposure meters use the LR-115 type 2 track threshold detector, which is sensitive to alpha particles.
Subject(s)
Air Pollutants, Radioactive , Air Pollution, Indoor , Radiation Monitoring , Radon , Air Pollutants, Radioactive/analysis , Air Pollution, Indoor/analysis , Alpha Particles , Radiation Monitoring/methods , Radon/analysisABSTRACT
The measurements were performed using a package of dielectric track detectors mounted behind the shield of 60-80 kg.m-2 thick. The charge of nuclei was determined from the complete track length. As a result, 1915 tracks of nuclei with Z greater than or equal to 6 in the energy range 100-450 MeV/nuclon were detected and identified. The differential charge spectrum of nuclei with 6 less than or equal to Z less than or equal to 28 and the energy spectrum of nuclei of the iron group were built. For iron nuclei the following ration of isotope groups was obtained: (Fe52 + Fe53 + Fe54): (Fe55 + Fe56 + Fe57) : (Fe58 + Fe59 + Fe60) = (0.30 +/- 0.08) = (0.49 +/- 0.10) : (0.21 +/- 0.05).