With the discovery of carcinogenic nitrosamine impurities in pharmaceuticals in 2018 and subsequent regulatory requirements for risk assessment for nitrosamine formation during pharmaceutical manufacturing processes, storage or from contaminated supply chains, effective testing of nitrosamines has become essential to ensure the quality of drug substances and products. Mass spectrometry has been widely applied to detect and quantify trace amounts of nitrosamines in pharmaceuticals. As part of an effort by regulatory authorities to assess the measurement variation in the determination of nitrosamines, an inter-laboratory study was performed by the laboratories from six regulatory agencies with each of the participants using their own analytical procedures to determine the amounts of nitrosamines in a set of identical samples. The results demonstrated that accurate and precise quantitation of trace level nitrosamines can be achieved across multiple analytical procedures and provided insight into the performance characteristics of mass spectrometry-based analytical procedures in terms of accuracy, repeatability and reproducibility.


Subject(s)
Nitrosamines , Humans , Nitrosamines/analysis , Reproducibility of Results , Mass Spectrometry , Pharmaceutical Preparations