Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 30
Filter
1.
Cancers (Basel) ; 13(24)2021 Dec 09.
Article in English | MEDLINE | ID: mdl-34944816

ABSTRACT

Facial muscle corticobulbar motor evoked potentials (FMcoMEPs) are used to monitor facial nerve integrity during vestibular schwannoma resections to increase maximal safe tumor resection. Established warning criteria, based on ipsilateral amplitude reduction, have the limitation that the rate of false positive alarms is high, in part because FMcoMEP changes occur on both sides, e.g., due to brain shift or pneumocephalus. We retrospectively compared the predictive value of ipsilateral-only warning criteria and actual intraoperative warnings with a novel candidate warning criterion, based on "ipsilateral versus contralateral difference in relative stimulation threshold increase, from baseline to end of resection" (BilatMT ≥ 20%), combined with an optimistic approach in which a warning would be triggered only if all facial muscles on the affected side deteriorated. We included 60 patients who underwent resection of vestibular schwannoma. The outcome variable was postoperative facial muscle function. Retrospectively applying BilatMT, with the optimistic approach, was found to have a significantly better false positive rate, which was much lower (9% at day 90) than the traditionally used ipsilateral warning criteria (>20%) and was also lower than actual intraoperative warnings. This is the first report combining the threshold method with an optimistic approach in a bilateral multi-facial muscle setup. This method could substantially reduce the rate of false positive alarms in FMcoMEP monitoring.

2.
Clin Neuroradiol ; 31(4): 1149-1157, 2021 Dec.
Article in English | MEDLINE | ID: mdl-33313974

ABSTRACT

PURPOSE: Intracranial lateral dural arteriovenous fistula (LDAVF) represents a specific subtype of cerebrovascular fistulae, harboring a potentially life-threatening risk of brain hemorrhage. Fluoroscopically guided endovascular embolization is the therapeutic gold standard. We provide detailed dosimetry data to suggest novel diagnostic reference levels (DRL). METHODS: Retrospective single-center study of LDAVFs treated between January 2014 and December 2019. Regarding dosimetry, the dose area product (DAP) and fluoroscopy time were analyzed for the following variables: Cognard scale grade, endovascular technique, angiographic outcome, and digital subtraction angiography (DSA) protocol. RESULTS: A total of 70 patients (19 female, median age 65 years) were included. Total median values for DAP and fluoroscopy time were 325 Gy cm2 (25%/75% percentile: 245/414 Gy cm2) and 110 min (68/142min), respectively. Neither median DAP nor fluoroscopy time were significantly different when comparing low-grade with high-grade LDAVF (Cognard I + IIa versus IIb-V; p > 0.05, each). Transvenous coil embolization yielded the lowest dosimetry values, with significantly lower median values when compared to a combined transarterial/transvenous technique (DAP 290 Gy cm2 versus 388 Gy cm2, p = 0.031; fluoroscopy time 85 min versus 170 min, p = 0.016). A significant positive correlation was found between number of arterial feeders treated by liquid embolization and both DAP (rs = 0.367; p = 0.010) and fluoroscopy time (rs = 0.295; p = 0.040). Complete LDAVF occlusion was associated with transvenous coiling (p = 0.001). A low-dose DSA protocol yielded a 20% reduction of DAP (p = 0.021). CONCLUSION: This LDAVF study suggests several local DRLs which varied substantially dependent on the endovascular technique and DSA protocol.


Subject(s)
Central Nervous System Vascular Malformations , Embolization, Therapeutic , Endovascular Procedures , Aged , Central Nervous System Vascular Malformations/diagnostic imaging , Central Nervous System Vascular Malformations/therapy , Female , Fluoroscopy , Humans , Radiation Dosage , Retrospective Studies
3.
Eur Radiol ; 29(6): 2859-2867, 2019 Jun.
Article in English | MEDLINE | ID: mdl-30635759

ABSTRACT

OBJECTIVES: Intraoperative CT (iCT) angiography of the brain with stereotactic frames is an integral part of navigated neurosurgery. Validated data regarding radiation dose and image quality in these special examinations are not available. We therefore investigated two iCT protocols in this IRB-approved study. METHODS: Retrospective analysis of patients, who received a cerebral stereotactic iCT angiography on a 128 slice CT scanner between February 2016 and December 2017. In group A, automated tube current modulation (ATCM; reference value 410 mAs) and automated tube voltage selection (reference value 120 kV) were enabled, and only examinations with a selected voltage of 120 kV were included. In group B, fixed parameters were applied (300 mAs, 120 kV). Radiation dose was measured by assessing the volumetric CT dose index (CTDIvol), dose length product (DLP) and effective dose (ED). Signal-to-noise ratio (SNR) and image noise were assessed for objective image quality, visibility of arteries and grey-white differentiation for subjective image quality. RESULTS: Two hundred patients (n = 100 in each group) were included. In group A, median selected tube current was 643 mAs (group B, 300 mAs; p < 0.001). Median values of CTDIvol, DLP and ED were 91.54 mGy, 1561 mGy cm and 2.97 mSv in group A, and 43.15 mGy, 769 mGy cm and 1.46 mSv in group B (p < 0.001). Image quality did not significantly differ between groups (p > 0.05). CONCLUSIONS: ATCM yielded disproportionally high radiation dose due to substantial tube current increase at the frame level, while image quality did not improve. Thus, ATCM should preferentially be disabled. KEY POINTS: • Automated tube current modulation (ATCM) yields disproportionally high radiation dose in intraoperative CT angiography of the brain with stereotactic head frames. • ATCM does not improve overall image quality in these special examinations. • ATCM is not yet optimised for CT angiography of the brain with major extracorporeal foreign materials within the scan range.


Subject(s)
Brain Neoplasms/diagnosis , Brain/diagnostic imaging , Cerebral Angiography/methods , Computed Tomography Angiography/methods , Imaging, Three-Dimensional , Neurosurgical Procedures/methods , Surgery, Computer-Assisted/methods , Adolescent , Adult , Aged , Aged, 80 and over , Brain/radiation effects , Brain Neoplasms/surgery , Female , Humans , Male , Middle Aged , Radiation Dosage , Retrospective Studies , Young Adult
4.
Sci Rep ; 8(1): 9228, 2018 06 15.
Article in English | MEDLINE | ID: mdl-29907855

ABSTRACT

We aimed to determine the diagnostic yield and accuracy of coronary CT angiography (CCTA) in patients referred for invasive coronary angiography (ICA) based on clinical concern for coronary artery disease (CAD) and an abnormal nuclear stress myocardial perfusion imaging (MPI) study. We enrolled 100 patients (84 male, mean age 59.6 ± 8.9 years) with an abnormal MPI study and subsequent referral for ICA. Each patient underwent CCTA prior to ICA. We analyzed the prevalence of potentially obstructive CAD (≥50% stenosis) on CCTA and calculated the diagnostic accuracy of ≥50% stenosis on CCTA for the detection of clinically significant CAD on ICA (defined as any ≥70% stenosis or ≥50% left main stenosis). On CCTA, 54 patients had at least one ≥50% stenosis. With ICA, 45 patients demonstrated clinically significant CAD. A positive CCTA had 100% sensitivity and 84% specificity with a 100% negative predictive value and 83% positive predictive value for clinically significant CAD on a per patient basis in MPI positive symptomatic patients. In conclusion, almost half (48%) of patients with suspected CAD and an abnormal MPI study demonstrate no obstructive CAD on CCTA.


Subject(s)
Computed Tomography Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Stenosis/diagnostic imaging , Myocardial Perfusion Imaging/methods , Aged , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies
5.
J Comput Assist Tomogr ; 41(2): 254-262, 2017.
Article in English | MEDLINE | ID: mdl-27636247

ABSTRACT

OBJECTIVE: The aim of this study was to define optimal tube potential for soft tissue and vessel visualization in dose-reduced chest CT protocols using model-based iterative algorithm in average and overweight patients. METHODS: Thirty-six patients receiving chest CT according to 3 protocols (120 kVp/noise index [NI], 60; 100 kVp/NI, 65; 80 kVp/NI, 70) were included in this prospective study, approved by the ethics committee. Patients' physical parameters and dose descriptors were recorded. Images were reconstructed with model-based algorithm. Two radiologists evaluated image quality and lesion conspicuity; the protocols were intraindividually compared with preceding control CT reconstructed with statistical algorithm (120 kVp/NI, 20). Mean and standard deviation of attenuation of the muscle and fat tissues and signal-to-noise ratio of the aorta were measured. RESULTS: Diagnostic images (lesion conspicuity, 95%-100%) were acquired in average and overweight patients at 1.34, 1.02, and 1.08 mGy and at 3.41, 3.20, and 2.88 mGy at 120, 100, and 80 kVp, respectively. Data are given as CT dose index volume values. CONCLUSIONS: Model-based algorithm allows for submillisievert chest CT in average patients; the use of 100 kVp is recommended.


Subject(s)
Body Weight , Models, Theoretical , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Thoracic/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Algorithms , Female , Humans , Male , Middle Aged , Overweight , Prospective Studies , Radiography, Thoracic/instrumentation , Tomography, X-Ray Computed/instrumentation
6.
Br J Radiol ; 89(1061): 20160003, 2016.
Article in English | MEDLINE | ID: mdl-26853510

ABSTRACT

OBJECTIVE: Evaluation of potential dose savings by implementing adaptive statistical iterative reconstruction (ASiR) on a gemstone-based scintillator in a clinical 64-row whole-body CT (WBCT) protocol after multiple trauma. METHODS: Dose reports of 152 WBCT scans were analysed for two 64-row multidetector CT scanners (Scanners A and B); the main scanning parameters were kept constant. ASiR and a gemstone-based scintillator were used in Scanner B, and the noise index was adjusted (head: 5.2 vs 6.0; thorax/abdomen: 29.0 vs 46.0). The scan length, CT dose index (CTDI) and dose-length product (DLP) were analysed. The estimated mean effective dose was calculated using normalized conversion factors. Student's t-test was used for statistics. RESULTS: Both the mean CTDI (mGy) (Scanner A: 53.8 ± 2.0, 10.3 ± 2.5, 14.4 ± 3.7; Scanner B: 48.7 ± 2.2, 7.1 ± 2.3, 9.1 ± 3.6; p < 0.001, respectively) and the mean DLP (mGy cm) (Scanner A: 1318.9 ± 167.8, 509.3 ± 134.7, 848.8 ± 254.0; Scanner B: 1190.6 ± 172.6, 354.6 ± 128.3, 561.0 ± 246.7; p < 0.001, respectively) for the head, thorax and abdomen were significantly reduced with Scanner B. There was no relevant difference in scan length. The total mean effective dose (mSv) was significantly decreased with Scanner B (24.4 ± 6.0, 17.2 ± 5.8; p < 0.001). CONCLUSION: The implementation of ASiR and a gemstone-based scintillator allows for significant dose savings in a clinical WBCT protocol. ADVANCES IN KNOWLEDGE: Recent technical developments can significantly reduce radiation dose of WBCT in multiple trauma. Dose reductions of 10-34% can be achieved.


Subject(s)
Image Processing, Computer-Assisted/methods , Multiple Trauma/diagnostic imaging , Radiation Dosage , Tomography Scanners, X-Ray Computed , Tomography, X-Ray Computed/methods , Whole Body Imaging/methods , Adult , Female , Humans , Male , Middle Aged , Radiographic Image Interpretation, Computer-Assisted , Retrospective Studies , Single-Blind Method , Tomography, X-Ray Computed/instrumentation , Whole Body Imaging/instrumentation
7.
Br J Radiol ; 89(1061): 20150827, 2016.
Article in English | MEDLINE | ID: mdl-26607648

ABSTRACT

OBJECTIVE: To investigate whether MRI in emergency radiology can detect (a) additional trauma-related findings after minor head injury (MHI) or (b) structural, non-trauma-related intracranial lesions when trauma biomarker S-100B concentration is raised, or clinical symptoms are unexplained, or both. METHODS: 41 patients with MHI were included. Concentrations of S-100B in serum were measured and categorized using an established cut-off at 0.1 µg l(-1). Intracerebral trauma-related as well as non-trauma-related chronic structural findings (atrophy, microangiopathy and chronic parenchymal defects) were assessed by cranial CT (CCT) and MRI by two independent radiologists (UL and LLG). All CCT and MRI results were compared with biomarker S-100B. RESULTS: Compared with CCT, MRI detected 10 additional lesions. 5 patients had abnormal MRI with a total of 15 trauma-related lesions and showed elevated S-100B concentrations. Although sensitivity of S-100B was 100%, specificity was only 25%. Patients with structural brain lesions showed significantly higher S-100B serum levels (0.50 and 0.14 µg l(-1), p = 0.01). CONCLUSION: Biomarker S-100B has proven its high negative-predictive value to rule out intracranial bleeding in patients after MHI even if MRI is used as imaging modality. Regarding the low specificity of S-100B, structural lesions of the brain parenchyma not related to the acute trauma may be associated with increased serum concentrations of protein S-100B. ADVANCES IN KNOWLEDGE: Biomarker S-100B has a high negative-predictive value to rule out intracranial bleeding after MHI. Biomarker S-100B's low specificity may be associated with non-traumatic brain parenchyma lesions. MRI is superior to CCT in detecting subtle findings in neuroimaging after MHI. Biomarker S-100B can potentially reduce the large number of normal CCT studies after MHI.


Subject(s)
Craniocerebral Trauma/blood , Craniocerebral Trauma/diagnosis , Emergency Medical Services , Magnetic Resonance Imaging , S100 Calcium Binding Protein beta Subunit/blood , Tomography, X-Ray Computed , Biomarkers/blood , Brain/diagnostic imaging , Brain/pathology , Female , Humans , Male , Middle Aged , Observer Variation , Reproducibility of Results , Sensitivity and Specificity
8.
Eur Radiol ; 26(9): 3215-22, 2016 Sep.
Article in English | MEDLINE | ID: mdl-26650935

ABSTRACT

OBJECTIVES: To assess quantitatively the impact of a novel reconstruction algorithm ("kernel") with beam-hardening correction (BHC) on beam-hardening artefacts of the myocardium at dual-energy CT myocardial perfusion imaging (DE-CTMPI). METHODS: Rest-series of DE-CTMPI examinations from 14 patients were retrospectively analyzed. Six image series were reconstructed for each patient: a) 100 kV, b) 140 kV, and c) linearly blended MIX0.5, each with BHC (D33f kernel) and without (D30f kernel). Seven hundred and fifty-six myocardial regions were assessed. Seven equal regions of interest divided the myocardium in the axial section. Three subdivisions were created within these regions in areas prone to BHA. Reports of SPECT studies performed within 30 days of CT examination were used to confirm the presence and location of true perfusion defects. Paired student t-test was used for statistical evaluation. RESULTS: Overall mean myocardial attenuation was lower using BHC (D30f: 87.3 ± 24.1 HU; D33f: 85.5 ± 21.5 HU; p = 0.009). Overall relative difference from average myocardial attenuation (RDMA) was more homogeneous using BHC (D30f: -0.3 ± 11.4 %; D33f: 0.1 ± 10.1 %; p < 0.001). Changes in RDMA were greatest in the posterobasal myocardium (D30f: -16.2 ± 10.0 %; D33f: 3.4 ± 10.7 %; p < 0.001). CONCLUSIONS: A dedicated reconstruction algorithm with BHC can significantly reduce beam-hardening artefacts in DE-CTMPI. KEY POINTS: • Beam-hardening artefacts (BHA) cause interference with attenuation-based CT myocardial perfusion assessment (CTMPI). • BHA occur mostly in the posterobasal left ventricular wall. • Beam-hardening correction homogenized and decreased mean myocardial attenuation. • BHC can help avoid false-positive findings and increase specificity of static CTMPI.


Subject(s)
Heart/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Aged , Algorithms , Artifacts , Female , Humans , Male , Middle Aged , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity , Tomography, Emission-Computed, Single-Photon
9.
Radiology ; 276(2): 339-57, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26203706

ABSTRACT

Owing to recent advances in computing power, iterative reconstruction (IR) algorithms have become a clinically viable option in computed tomographic (CT) imaging. Substantial evidence is accumulating about the advantages of IR algorithms over established analytical methods, such as filtered back projection. IR improves image quality through cyclic image processing. Although all available solutions share the common mechanism of artifact reduction and/or potential for radiation dose savings, chiefly due to image noise suppression, the magnitude of these effects depends on the specific IR algorithm. In the first section of this contribution, the technical bases of IR are briefly reviewed and the currently available algorithms released by the major CT manufacturers are described. In the second part, the current status of their clinical implementation is surveyed. Regardless of the applied IR algorithm, the available evidence attests to the substantial potential of IR algorithms for overcoming traditional limitations in CT imaging.


Subject(s)
Algorithms , Image Processing, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Humans
10.
Acad Radiol ; 22(9): 1138-46, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26094116

ABSTRACT

RATIONALE AND OBJECTIVES: To investigate the diagnostic performance of a comprehensive computed tomography (CT) protocol for both cardiac and aortoiliac evaluation of patients considered for transcatheter aortic valve replacement (TAVR) using a single, low-volume contrast medium (CM) injection. MATERIALS AND METHODS: Forty-four TAVR candidates were retrospectively analyzed. All underwent retrospectively electrocardiogram-gated cardiac CT followed by high-pitch CT angiography of the aortoiliac vasculature using one of two single injection protocols of 320 mgI/mL iodine CM: group A (n = 22), iodine delivery rate-based (1.28 gI/s), 60-mL CM volume, 4.0 mL/s flow rate; group B (n = 22), clinical routine protocol, 100-mL CM volume, 4.0 mL/s flow rate. Mean arterial attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated. Subjective image quality was assessed. RESULTS: Aortic root and iliofemoral dimensions could be analyzed in all cases. Patient characteristics showed no significant differences. Mean attenuation at the levels of the aortic root (285.8 ± 83.0 HU vs 327.5 ± 70.8 HU, P = .080) and the iliofemoral access route (256.8 ± 88.5 HU vs 307.5 ± 93.2 HU, P = .071), as well as SNR and CNR were nonsignificantly lower in group A compared to group B. Subjective image quality was equivalent. CONCLUSIONS: In multimorbid TAVR patients, the performance of a combined CT protocol using a single low-volume CM bolus is feasible with maintained image quality compared to a standard protocol.


Subject(s)
Aortography/methods , Computed Tomography Angiography/methods , Contrast Media/administration & dosage , Heart/diagnostic imaging , Iliac Artery/diagnostic imaging , Tomography, X-Ray Computed/methods , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Cardiac-Gated Imaging Techniques/methods , Feasibility Studies , Female , Humans , Image Processing, Computer-Assisted/methods , Male , Patient Care Planning , Radiation Dosage , Retrospective Studies , Signal-To-Noise Ratio , Triiodobenzoic Acids/administration & dosage
11.
Eur J Endocrinol ; 173(2): 197-204, 2015 Aug.
Article in English | MEDLINE | ID: mdl-25953828

ABSTRACT

OBJECTIVE: The aim of the present study was to validate criteria of corticotropin-releasing hormone (CRH) stimulation and 8 mg dexamethasone suppression (high-dose dexamethasone suppression, HDDS) to distinguish the etiology of ACTH-dependent Cushing's syndrome. SUBJECTS AND METHODS: We retrospectively analyzed cortisol and ACTH after the injection of 100 µg human CRH in confirmed Cushing's disease (CD, n=78) and confirmed ectopic Cushing's syndrome (ECS, n=18). Cortisol and ACTH increase (in percentage above basal (%B)) at each time point, maximal increase (Δmax %B), and area under the curve (AUC %B) were analyzed using receiver operator characteristics (ROC) curve analyses. Cortisol suppression (%B) after 8 mg of dexamethasone was evaluated as a supplementary criterion. RESULTS: An increase in ACTH of ≥ 43%B at 15 min after CRH was the strongest predictor of CD, with a positive likelihood ratio of 14.0, a sensitivity of 83%, a specificity of 94%, a positive predictive value of 98% and a negative predictive value of 58%. All of the other criteria of stimulated ACTH and cortisol levels were not superior in predicting CD in response to CRH injection. The addition of cortisol suppression by dexamethasone did not increase the discriminatory power. However, the combination of a positive ACTH response at 15 min and a positive HDDS test excluded ECS in all cases. CONCLUSION: The present findings support the use of plasma ACTH levels 15 min after the injection of human CRH as a response criterion for distinguishing between CD and ECS. The addition of the HDDS test is helpful for excluding ECS when both tests are positive.


Subject(s)
Adrenocorticotropic Hormone/blood , Corticotropin-Releasing Hormone/blood , Cushing Syndrome/blood , Cushing Syndrome/diagnosis , Pituitary ACTH Hypersecretion/blood , Pituitary ACTH Hypersecretion/diagnosis , Adult , Biomarkers/blood , Diagnosis, Differential , Female , Humans , Male , Middle Aged , Retrospective Studies , Time Factors
12.
Eur J Radiol ; 84(6): 1062-7, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25843418

ABSTRACT

OBJECTIVES: To systematically analyze the influence of technical parameters on quantification of epicardial fat volume (EATV) at cardiac CT. METHODS: 153 routine cardiac CT data sets were analyzed using three-dimensional pericardial border delineation. Three image series were reconstructed per patient: (a) CTAD: coronary CT angiography (CTA), diastolic phase; (b) CTAS: coronary CTA, systolic phase; (c) CaScD: non-contrast CT, diastolic phase. EATV was calculated using three different upper thresholds (-15HU, -30 HU, -45HU). Repeated measures ANOVA, Spearman's rho, and Bland Altman plots were used. RESULTS: Mean EATV differed between all three image series at a -30HU threshold (CTAD 87.2 ± 38.5 ml, CTAS 90.9 ± 37.7 ml, CaScD 130.7 ± 49.5 ml, P<0.001). EATV of diastolic and systolic CTA reconstructions did not differ significantly (P=0.225). Mean EATV for contrast enhanced CTA at a -15HU threshold (CTAD15 102.4 ± 43.6 ml, CTAS15 105.3 ± 42.3 ml) could be approximated most closely by non-contrast CT at -45HU threshold (CaScD45 105.3 ± 40.8 ml). The correlation was excellent: CTAS15-CTAD15, rho=0.943; CTAD15-CaScD45, rho=0.905; CTAS15-CaScD45, rho=0.924; each P<0.001). Bias values from Bland Altman Analysis were: CTAS15-CTAD15, 4.9%; CTAD15-CaScD45, -4.3%; CTAS15-CaScD45, 0.6%. CONCLUSIONS: Measured EATV can differ substantially between contrast enhanced and non-contrast CT studies, which can be reconciled by threshold modification. Heart cycle phase does not significantly influence EATV measurements.


Subject(s)
Adipose Tissue/pathology , Coronary Angiography , Coronary Artery Disease/pathology , Pericardium/pathology , Tomography, X-Ray Computed , Adipose Tissue/diagnostic imaging , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Diastole , Female , Humans , Male , Middle Aged , Pericardium/diagnostic imaging , Systole , Tomography, X-Ray Computed/methods
13.
Radiology ; 276(3): 706-14, 2015 Sep.
Article in English | MEDLINE | ID: mdl-25786157

ABSTRACT

PURPOSE: To use suitable objective methods of analysis to assess the influence of the combination of an integrated-circuit computed tomographic (CT) detector and iterative reconstruction (IR) algorithms on the visualization of small (≤3-mm) coronary artery stents. MATERIALS AND METHODS: By using a moving heart phantom, 18 data sets obtained from three coronary artery stents with small diameters were investigated. A second-generation dual-source CT system equipped with an integrated-circuit detector was used. Images were reconstructed with filtered back-projection (FBP) and IR at a section thickness of 0.75 mm (FBP75 and IR75, respectively) and IR at a section thickness of 0.50 mm (IR50). Multirow intensity profiles in Hounsfield units were modeled by using a sum-of-Gaussians fit to analyze in-plane image characteristics. Out-of-plane image characteristics were analyzed with z upslope of multicolumn intensity profiles in Hounsfield units. Statistical analysis was conducted with one-way analysis of variance and the Student t test. RESULTS: Independent of stent diameter and heart rate, IR75 resulted in significantly increased xy sharpness, signal-to-noise ratio, and contrast-to-noise ratio, as well as decreased blurring and noise compared with FBP75 (eg, 2.25-mm stent, 0 beats per minute; xy sharpness, 278.2 vs 252.3; signal-to-noise ratio, 46.6 vs 33.5; contrast-to-noise ratio, 26.0 vs 16.8; blurring, 1.4 vs 1.5; noise, 15.4 vs 21.2; all P < .001). In the z direction, the upslopes were substantially higher in the IR50 reconstructions (2.25-mm stent: IR50, 94.0; IR75, 53.1; and FBP75, 48.1; P < .001). CONCLUSION: The implementation of an integrated-circuit CT detector provides substantially sharper out-of-plane resolution of coronary artery stents at 0.5-mm section thickness, while the use of iterative image reconstruction mostly improves in-plane stent visualization.


Subject(s)
Coronary Vessels , Image Processing, Computer-Assisted , Stents , Tomography, X-Ray Computed , Algorithms , Phantoms, Imaging , Prosthesis Design
14.
J Clin Endocrinol Metab ; 100(4): 1300-8, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25546155

ABSTRACT

CONTEXT: Successful tumor resection in endogenous Cushing's syndrome (CS) results in tertiary adrenal insufficiency requiring hydrocortisone replacement therapy. OBJECTIVE: The aim was to analyze the postsurgical duration of adrenal insufficiency of patients with Cushing's disease (CD), adrenal CS, and ectopic CS. DESIGN: We performed a retrospective analysis based on the case records of 230 patients with CS in our tertiary referral center treated from 1983-2014. The mean follow-up time was 8 years. PATIENTS: We included 91 patients of the three subtypes of CS undergoing curative intended surgery and documented followup after excluding cases with persistent disease, pituitary radiation, concurrent adrenostatic or somatostatin analog treatment, and malignant adrenal disease. RESULTS: The probability of recovering adrenal function within a 5 years followup differed significantly between subtypes (P = .001). It was 82% in ectopic CS, 58% in CD and 38% in adrenal CS. In the total cohort with restored adrenal function (n = 52) the median time to recovery differed between subtypes: 0.6 years (interquartile range [IQR], 0.03-1.1 y) in ectopic CS, 1.4 years (IQR, 0.9-3.4 y) in CD, and 2.5 years (IQR, 1.6-5.4 y) in adrenal CS (P = .002). In CD the Cox proportional-hazards model showed that the probability of recovery was associated with younger age (hazard ratio, 0.896; 95% confidence interval, 0.822-0.976; P = .012), independently of sex, body mass index, duration of symptoms, and basal ACTH and cortisol levels. There was no correlation with length and extend of hypercortisolism or postoperative glucocorticoid replacement doses. CONCLUSIONS: Time to recovery of adrenal function is dependent on the underlying etiology of CS.


Subject(s)
Adrenal Glands/physiology , Cushing Syndrome/etiology , Cushing Syndrome/rehabilitation , Recovery of Function , ACTH-Secreting Pituitary Adenoma/rehabilitation , ACTH-Secreting Pituitary Adenoma/surgery , Adenoma/complications , Adenoma/rehabilitation , Adenoma/surgery , Adrenal Insufficiency/etiology , Adrenal Insufficiency/rehabilitation , Adrenal Insufficiency/surgery , Adult , Cushing Syndrome/surgery , Female , Follow-Up Studies , Humans , Male , Middle Aged , Recurrence , Retrospective Studies , Time Factors
15.
Eur Radiol ; 24(11): 2677-84, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25052076

ABSTRACT

OBJECTIVES: To evaluate the effect of automated tube voltage selection on radiation dose and image quality at cardiovascular CT angiography (CTA). METHODS: We retrospectively analysed paired studies in 72 patients (41 male, 60.5 ± 16.5 years), who had undergone CTA acquisitions of the heart or aorta both before and after the implementation of an automated x-ray tube voltage selection algorithm (ATVS). All other parameters were kept identical between the two acquisitions. Subjective image quality (IQ) was rated and objective IQ was measured by image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and figure of merit (FOM). Image quality parameters and effective dose were compared between acquisitions. RESULTS: Overall subjective image quality improved with the percentage of cases scored as adequate or higher increasing from 79 % to 92 % after implementation of ATVS (P = 0.03). SNR (14.1 ± 5.9, 15.7 ± 6.1, P = 0.009), CNR (11.6 ± 5.3, 13.2 ± 5.6, P = 0.011), and FOM (19.9 ± 23.3, 43.8 ± 51.1, P < 0.001) were significantly higher after implementation of ATVS. Mean image noise (24.1 ± 8.4 HU, 22.7 ± 7.1 HU, P = 0.048) and mean effective dose (10.6 ± 5.9 mSv, 8.8 ± 5.0 mSv, P = 0.003) were significantly lower after implementation of ATVS. CONCLUSIONS: Automated tube voltage selection can operator-independently optimize cardiovascular CTA image acquisition parameters with improved image quality at reduced dose. KEY POINTS: • Automatic tube voltage selection optimizes tube voltage for each individual patient. • In this population, overall radiation dose decreased while image quality improved. • This tool may become valuable for improving dose/quality ratio.


Subject(s)
Algorithms , Angiography/methods , Image Enhancement/methods , Pulmonary Embolism/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Aged , Contrast Media , Female , Follow-Up Studies , Humans , Male , Middle Aged , Radiation Dosage , Reproducibility of Results , Retrospective Studies
16.
Acad Radiol ; 21(7): 938-44, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24928163

ABSTRACT

RATIONALE AND OBJECTIVES: To evaluate the performance of radiology residents in the interpretation of on-call, emergency "triple-rule-out" (TRO) computed tomographic (CT) studies in patients with acute chest pain. MATERIALS AND METHODS: The study was institutional review board-approved and Health Insurance Portability and Accountability Act compliant. Data from 617 on-call TRO studies were analyzed. Dedicated software enables subspecialty attendings to grade discrepancies in interpretation between preliminary trainee reports and their final interpretation as "unlikely to be significant" (minor discrepancies) or "likely to be significant" for patient management (major discrepancies). The frequency of minor, major and all discrepancies in resident's TRO interpretations was compared to 609 emergent non-electrocardiography (ECG)-synchronized chest CT studies using Pearson χ(2) test. RESULTS: Minor discrepancies occurred more often in the TRO group (9.1% vs. 3.9%, P < .001), but there was no difference in the frequency of major discrepancies (2.1% vs. 2.8%, P = .55). Minor discrepancies in the TRO group most commonly resulted from missed extrathoracic findings with missed liver lesions being the most frequent. Major discrepancies mostly encompassed cardiac and extracardiac vascular findings but did not result in unnecessary interventions, significant immediate changes in management, or adverse patient outcomes. CONCLUSIONS: On-call resident interpretation of TRO CT studies in patients with acute chest pain is congruent with final subspecialty attending interpretation in the overwhelming majority of cases. The rate of discrepancies likely to affect patient management in this domain is not different from emergent non-ECG-synchronized chest CT.


Subject(s)
After-Hours Care/statistics & numerical data , Aortic Diseases/diagnostic imaging , Chest Pain/diagnostic imaging , Clinical Competence/statistics & numerical data , Coronary Stenosis/diagnostic imaging , Internship and Residency/statistics & numerical data , Tomography, X-Ray Computed/statistics & numerical data , Acute Disease , Diagnosis, Differential , Humans , Observer Variation , Pulmonary Embolism , Reproducibility of Results , Sensitivity and Specificity , South Carolina
17.
J Thorac Imaging ; 29(4): 198-208, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24662334

ABSTRACT

Iterative image reconstruction algorithms provide significant improvements over traditional filtered back projection in computed tomography (CT). Clinically available through recent advances in modern CT technology, iterative reconstruction enhances image quality through cyclical image calculation, suppressing image noise and artifacts, particularly blooming artifacts. The advantages of iterative reconstruction are apparent in traditionally challenging cases-for example, in obese patients, those with significant artery calcification, or those with coronary artery stents. In addition, as clinical use of CT has grown, so have concerns over ionizing radiation associated with CT examinations. Through noise reduction, iterative reconstruction has been shown to permit radiation dose reduction while preserving diagnostic image quality. This approach is becoming increasingly attractive as the routine use of CT for pediatric and repeated follow-up evaluation grows ever more common. Cardiovascular CT in particular, with its focus on detailed structural and functional analyses, stands to benefit greatly from the promising iterative solutions that are readily available.


Subject(s)
Algorithms , Coronary Angiography/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Artifacts , Comorbidity , Coronary Vessels/diagnostic imaging , Humans , Obesity/epidemiology , Radiation Dosage
18.
Semin Respir Crit Care Med ; 35(1): 50-63, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24481759

ABSTRACT

The respiratory and the cardiovascular systems are intimately connected. Because of the high degree of morphological and functional interaction, pathophysiological processes in one compartment are likely to induce adaptive changes in the other. Computed tomography (CT) plays a central role in the diagnostic work up of both thoracic and cardiac disorders. Historically, these two systems have been evaluated separately; however, CT technology has evolved remarkably over recent decades. Up-to-date advanced imaging strategies allow for a combined assessment of the cardiopulmonary unit. Besides improved techniques of electrocardiogram (ECG)-synchronization for obtaining both morphological and functional information, latest advances of dual-source CT (DSCT) have shown great promise for even more comprehensive integrated cardiothoracic imaging.


Subject(s)
Cardiovascular Diseases/diagnosis , Thoracic Diseases/diagnosis , Tomography, X-Ray Computed/methods , Cardiovascular Diseases/physiopathology , Electrocardiography/methods , Humans , Radiography, Dual-Energy Scanned Projection/methods , Thoracic Diseases/physiopathology , Tomography, X-Ray Computed/trends
19.
Radiology ; 271(2): 574-84, 2014 May.
Article in English | MEDLINE | ID: mdl-24475853

ABSTRACT

PURPOSE: To determine the lower limit of dose reduction with hybrid and fully iterative reconstruction algorithms in detection of endoleaks and in-stent thrombus of thoracic aorta with computed tomographic (CT) angiography by applying protocols with different tube energies and automated tube current modulation. MATERIALS AND METHODS: The calcification insert of an anthropomorphic cardiac phantom was replaced with an aortic aneurysm model containing a stent, simulated endoleaks, and an intraluminal thrombus. CT was performed at tube energies of 120, 100, and 80 kVp with incrementally increasing noise indexes (NIs) of 16, 25, 34, 43, 52, 61, and 70 and a 2.5-mm section thickness. NI directly controls radiation exposure; a higher NI allows for greater image noise and decreases radiation. Images were reconstructed with filtered back projection (FBP) and hybrid and fully iterative algorithms. Five radiologists independently analyzed lesion conspicuity to assess sensitivity and specificity. Mean attenuation (in Hounsfield units) and standard deviation were measured in the aorta to calculate signal-to-noise ratio (SNR). Attenuation and SNR of different protocols and algorithms were analyzed with analysis of variance or Welch test depending on data distribution. RESULTS: Both sensitivity and specificity were 100% for simulated lesions on images with 2.5-mm section thickness and an NI of 25 (3.45 mGy), 34 (1.83 mGy), or 43 (1.16 mGy) at 120 kVp; an NI of 34 (1.98 mGy), 43 (1.23 mGy), or 61 (0.61 mGy) at 100 kVp; and an NI of 43 (1.46 mGy) or 70 (0.54 mGy) at 80 kVp. SNR values showed similar results. With the fully iterative algorithm, mean attenuation of the aorta decreased significantly in reduced-dose protocols in comparison with control protocols at 100 kVp (311 HU at 16 NI vs 290 HU at 70 NI, P ≤ .0011) and 80 kVp (400 HU at 16 NI vs 369 HU at 70 NI, P ≤ .0007). CONCLUSION: Endoleaks and in-stent thrombus of thoracic aorta were detectable to 1.46 mGy (80 kVp) with FBP, 1.23 mGy (100 kVp) with the hybrid algorithm, and 0.54 mGy (80 kVp) with the fully iterative algorithm.


Subject(s)
Algorithms , Angiography/methods , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Endoleak/diagnostic imaging , Endoleak/etiology , Phantoms, Imaging , Postoperative Complications/diagnostic imaging , Postoperative Complications/etiology , Stents , Thrombosis/diagnostic imaging , Thrombosis/etiology , Tomography, X-Ray Computed/methods , Contrast Media , Humans , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted
20.
Forensic Sci Med Pathol ; 10(2): 170-8, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24443143

ABSTRACT

PURPOSE: To compare low-dose computed tomography (CT) with standard CT and conventional radiography (CR) regarding delineation of body packs and radiation dose. METHODS: Nine samples of illicit drugs including cocaine, heroin, and hashish were positioned in the rectum of a 121.5 kg pig cadaver. Each sample was scanned on a 64-row MDCT with 120 kV: one standard modulated pelvic protocol (STD), and without modulation at 80 mA (LD80), 30 mA (LD30), and 10 mA (LD10). Additionally, conventional abdominal anterior-posterior radiographs (77 kV and 106 ± 13 mA) were taken. Body pack characteristics (wrapping, content, shape) were rated independently by two radiologists and summarized to a delineation score from 0 to 9 with scores ≥6 representing sufficient delineation. Mean delineation scores were calculated for CR and CT protocols. These were additionally differentiated for readings in soft tissue (S), lung (L), user defined, variable window settings (V), and in cumulative window evaluation including all the other window settings (SLV). Effective doses were calculated (mSv). RESULTS: The CR delineation score was insufficient (3.1 ± 2.5; 2.4 ± 0.3 mSv). For CT, the SLV window setting performed best (p < 0.01). Its score significantly (p < 0.01) declined with decreasing effective radiation doses: STD (8.8 ± 0.5; 10.6 mSv), LD80 (8.2 ± 0.7; 2.6 mSv), LD30 (6.8 ± 1.3; 1.0 mSv), and LD10 (4.6 ± 1.9; 0.3 mSv). Thus, LD30 was the protocol using the lowest but sufficient dose. Moreover, for LD30 further differentiation between the particular window settings resulted in scores of 6.4 ± 1.3 (L), 6.3 ± 1.2 (V), and 3.1 ± 1.0 (S). CONCLUSIONS: With appropriate window settings, low-dose CT at 30 mA allowed for sufficient body-pack delineation below the dose of CR, which itself performed insufficient.


Subject(s)
Foreign Bodies/diagnostic imaging , Illicit Drugs , Multidetector Computed Tomography/methods , Radiation Dosage , Animals , Crime , Models, Animal , Pelvis/diagnostic imaging , Radiography, Abdominal , Swine , Travel
SELECTION OF CITATIONS
SEARCH DETAIL
...