1.
Front Psychol ; 13: 846610, 2022.
Article in English | MEDLINE | ID: mdl-35401342

ABSTRACT

Visual inspections have been typically used in condition assessment of infrastructure. However, they are based on human judgment and their interpretation of data can differ from acquired results. In psychology, this difference is called cognitive bias which directly affects Structural Health Monitoring (SHM)-based decision making. Besides, the confusion between condition state and safety of a bridge is another example of cognitive bias in bridge monitoring. Therefore, integrated computer-based approaches as powerful tools can be significantly applied in SHM systems. This paper explores the relationship between the use of advanced computational intelligence and the development of SHM solutions through conducting an infrastructure monitoring methodology. Artificial Intelligence (AI)-based algorithms, i.e., Artificial Neural Network (ANN), hybrid ANN-based Imperial Competitive Algorithm, and hybrid ANN-based Genetic Algorithm, are developed for damage assessment using a lab-scale composite bridge deck structure. Based on the comparison of the results, the employed evolutionary algorithms could improve the prediction error of the pre-developed network by enhancing the learning procedure of the ANN.

2.
PLoS One ; 13(7): e0200482, 2018.
Article in English | MEDLINE | ID: mdl-30059506

ABSTRACT

This paper investigated the seismic retrofitting of an existing cable-stayed bridge through the use of a seismic isolation system. The bridge is situated in a high seismic zone. During the Saguenay earthquake 1988, one of the anchorage plates of the bridge supports failed. Herein, several configurations of seismic isolation system were considered to identify an appropriate solution for the seismic retrofitting of the bridge in both the longitudinal and transverse directions. A three-dimensional model of the bridge was created, and its seismic behavior studied through nonlinear dynamic time-history analysis. The comparative performance study among the five retrofitting configurations showed that the partial seismic isolation of the bridge led to an enhancement of the seismic response of the bridge in one direction only. However, the overall seismic response of the cable-stayed bridge substantially improved in the longitudinal and transverse directions in cases where the isolation systems were utilized between the supports and the deck-tower connection of the bridge.


Subject(s)
Disasters , Earthquakes , Steel , Structure Collapse/prevention & control , Canada , Construction Materials , Equipment Design , Motion , Nonlinear Dynamics
SELECTION OF CITATIONS
SEARCH DETAIL
...