1.
Membranes (Basel) ; 12(10)2022 Oct 14.
Article in English | MEDLINE | ID: mdl-36295759

ABSTRACT

A detailed numerical study of ethyl levulinate (EtLA) production with levulinic acid (LA) and ethanol (Et) in a multi-bed traditional reactor (MB-TR) and a silica-based and polymeric multi-bed pervaporation membrane reactors (MB-PVMR) was conducted and the efficiency of each design was studied under different operation conditions. Due to water production in the EtLA production process, water removal by a pervaporation system may improve process performance. Our results showed that MB-PVMR had higher performance compared with MB-TR. In addition, the silica membrane was more effective in water removal compared with the polymeric membrane. Therefore, higher LA conversion was achievable by a silica-based multi-bed pervaporation membrane reactor (SMB-PVMR). All the results were evaluated for percentage of water removal and LA conversion, based on variations in the Et/LA molar ratio, feed molar flow, reaction zone temperature, and catalyst loading. The results showed that water removal was higher than 95% and LA conversion of about 95% was attained by SMB-PVMR.

2.
Nanomaterials (Basel) ; 12(5)2022 Feb 28.
Article in English | MEDLINE | ID: mdl-35269312

ABSTRACT

In this work, a novel structure of a hydrogen-membrane reactor coupling HI decomposition and CO2 methanation was proposed, and it was based on the adoption of silica membranes instead of metallic, according to their ever more consistent utilization as nanomaterial for hydrogen separation/purification. A 2D model was built up and the effects of feed flow rate, sweep gas flow rate and reaction pressure were examined by CFD simulation. This work well proves the feasibility and advantage of the membrane reactor that integrates HI decomposition and CO2 methanation reactions. Indeed, two membrane reactor systems were compared: on one hand, a simple membrane reactor without proceeding towards any CO2 methanation reaction; on the other hand, a membrane reactor coupling the HI decomposition with the CO2 methanation reaction. The simulations demonstrated that the hydrogen recovery in the first membrane reactor was higher than the methanation membrane reactor. This was due to the consumption of hydrogen during the CO2 methanation reaction, occurring in the permeate side of the second membrane reactor system, which lowered the amount of hydrogen recovered in the outlet streams. After model validation, this theoretical study allows one to evaluate the effect of different operating parameters on the performance of both the membrane reactors, such as the pressure variation between 1 and 5 bar, the feed flow rate between 10 and 50 mm3/s and the sweep gas flow rate between 166.6 and 833.3 mm3/s. The theoretical predictions demonstrated that the best results in terms of HI conversion were 74.5% for the methanation membrane reactor and 67% for the simple membrane reactor.

3.
Membranes (Basel) ; 11(8)2021 Aug 17.
Article in English | MEDLINE | ID: mdl-34436398

ABSTRACT

Pervaporation is a peculiar membrane separation process, which is considered for integration with a variety of reactions in promising new applications. Pervaporation membrane reactors have some specific uses in sustainable chemistry, such as the esterification processes. This theoretical study based on the computational fluid dynamics method aims to evaluate the performance of a multi-bed pervaporation membrane reactor (including poly (vinyl alcohol) membrane) to produce ethyl levulinate as a significant fuel additive, coming from the esterification of levulinic acid. For comparison, an equivalent multi-bed traditional reactor is also studied at the same operating conditions of the aforementioned pervaporation membrane reactor. A computational fluid dynamics model was developed and validated by experimental literature data. The effects of reaction temperature, catalyst loading, feed molar ratio, and feed flow rate on the reactor's performance in terms of levulinic acid conversion and water removal were hence studied. The simulations indicated that the multi-bed pervaporation membrane reactor results to be the best solution over the multi-bed traditional reactor, presenting the best simulation results at 343 K, 2 bar, catalyst loading 8.6 g, feed flow rate 7 mm3/s, and feed molar ratio 3 with levulinic acid conversion equal to 95.3% and 91.1% water removal.

4.
Molecules ; 24(23)2019 Nov 28.
Article in English | MEDLINE | ID: mdl-31795204

ABSTRACT

The purification of H2-rich streams using membranes represents an important separation process, particularly important in the viewpoint of pre-combustion CO2 capture. In this study, the separation of H2 from a mixture containing H2 and CO2 using a zeolitic imidazolate framework (ZIF)-8 membrane is proposed from a theoretical point of view. For this purpose, the adsorption and diffusion coefficients of H2 and CO2 were considered by molecular simulation. The adsorption of these gases followed the Langmuir model, and the diffusion coefficient of H2 was much higher than that of CO2. Then, using the Maxwell-Stefan model, the H2 and CO2 permeances and H2/CO2 permselectivities in the H2-CO2 mixtures were evaluated. Despite the fact that adsorption of CO2 was higher than H2, owing to the simultaneous interference of adsorption and diffusion processes in the membrane, H2 permeation was more pronounced than CO2. The modeling results showed that, for a ZIF-8 membrane, the H2/CO2 permselectivity for the H2-CO2 binary mixture 80/20 ranges between 28 and 32 at ambient temperature.


Subject(s)
Carbon Dioxide/chemistry , Deuterium/chemistry , Membranes, Artificial , Models, Chemical , Models, Molecular , Zeolites/chemistry , Algorithms
5.
Membranes (Basel) ; 9(8)2019 Aug 10.
Article in English | MEDLINE | ID: mdl-31405178

ABSTRACT

Biohydrogen is a clean and viable energy carrier generated through various green and renewable energy sources such as biomass. This review focused on the application of membrane bioreactors (MBRs), emphasizing the combination of these devices with biological processes, for bio-derived hydrogen production. Direct biophotolysis, indirect biophotolysis, photo-fermentation, dark fermentation, and conventional techniques are discussed as the common methods of biohydrogen production. The anaerobic process membrane bioreactors (AnMBRs) technology is presented and discussed as a preferable choice for producing biohydrogen due to its low cost and the ability of overcoming problems posed by carbon emissions. General features of AnMBRs and operational parameters are comprehensively overviewed. Although MBRs are being used as a well-established and mature technology with many full-scale plants around the world, membrane fouling still remains a serious obstacle and a future challenge. Therefore, this review highlights the main benefits and drawbacks of MBRs application, also discussing the comparison between organic and inorganic membranes utilization to determine which may constitute the best solution for providing pure hydrogen. Nevertheless, research is still needed to overcome remaining barriers to practical applications such as low yields and production rates, and to identify biohydrogen as one of the most appealing renewable energies in the future.

6.
Membranes (Basel) ; 9(9)2019 Aug 27.
Article in English | MEDLINE | ID: mdl-31461938

ABSTRACT

The main purposes of this study are to evaluate the performance of graphene membranes in the separation/purification of hydrogen from nitrogen from a theoretical point of view using the molecular dynamic (MD) simulation method, and to present details about molecular mechanisms of selective gas diffusion through nanoscale pores of graphene membranes at the simulated set conditions. On the other hand, permeance and perm-selectivity are two significant parameters of such a membrane that can be controlled by several variables such as pressure gradient, pore density, pore layer angles etc. Hence, in this work, the hydrogen and nitrogen permeating fluxes as well as the H2/N2 ideal perm-selectivity are investigated from a theoretical point of view in a two-layer nanoporous graphene (NPG) membrane through classical MD simulations, wherein the effects of pressure gradient, pore density, and pore angle on the NPG membrane performance are evaluated and discussed. Simulation outcomes suggest that hydrogen and nitrogen permeating fluxes increase as a consequence of an increment of pressure gradient across the membrane and pore density.

7.
Membranes (Basel) ; 8(3)2018 Aug 17.
Article in English | MEDLINE | ID: mdl-30126137

ABSTRACT

Hydrogen has attracted growing attention for various uses, and, particularly, for polymer electrolyte membrane fuel cells (PEMFCs) supply. However, PEMFCs need high grade hydrogen, which is difficult in storing and transportation. To solve these issues, hydrogen generation from alcohols and hydrocarbons steam reforming reaction has gained great consideration. Among the various renewable fuels, methanol is an interesting hydrogen source because at room temperature it is liquid, and then, easy to handle and to store. Furthermore, it shows a relatively high H/C ratio and low reforming temperature, ranging from 200 to 300 °C. In the field of hydrogen generation from methanol steam reforming reaction, a consistent literature is noticeable. Despite various reviews that are more devoted to describe from an experimental point of view the state of the art about methanol steam reforming reaction carried in conventional and membrane reactors, this work describes the progress in the last two decades about the modelling studies on the same reaction in membrane reactors.

8.
Biomed Mater Eng ; 27(2-3): 119-29, 2016 Aug 12.
Article in English | MEDLINE | ID: mdl-27567769

ABSTRACT

Laminar, turbulent, transitional, or combine areas of all three types of viscous flow can occur downstream of a stenosis depending upon the Reynolds number and constriction shape parameter. Neither laminar flow solver nor turbulent models for instance the k-ω (k-omega), k-ε (k-epsilon), RANS or LES are opportune for this type of flow. In the present study attention has been focused vigorously on the effect of the constriction in the flow field with a unique way. It means that the laminar solver was employed from entry up to the beginning of the turbulent shear flow. The turbulent model (k-ω SST Transitional Flows) was utilized from starting of turbulence to relaminarization zone while the laminar model was applied again with onset of the relaminarization district. Stenotic flows, with 50 and 75% cross-sectional area, were simulated at Reynolds numbers range from 500 to 2000 employing FLUENT (v6.3.17). The flow was considered to be steady, axisymmetric, and incompressible. Achieving results were reported as axial velocity, disturbance velocity, wall shear stress and the outcomes were compared with previously experimental and CFD computations. The analogy of axial velocity profiles shows that they are in acceptable compliance with the empirical data. As well as disturbance velocity and wall shear stresses anticipated by this new approach, part by part simulation, are reasonably valid with the acceptable experimental studies.


Subject(s)
Arterial Occlusive Diseases/physiopathology , Arteries/physiopathology , Constriction, Pathologic/physiopathology , Blood Flow Velocity , Computer Simulation , Humans , Models, Cardiovascular , Pulsatile Flow , Stress, Mechanical
SELECTION OF CITATIONS