Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Rev. Inst. Adolfo Lutz (Online) ; 83: 40325, 30 jan. 2024. tab, graf
Article in English | LILACS, CONASS, Coleciona SUS, Sec. Est. Saúde SP, SESSP-ACVSES, SESSP-IALPROD, Sec. Est. Saúde SP, SESSP-IALACERVO | ID: biblio-1555946

ABSTRACT

Endotoxin contamination is a threat to the safety of pharmaceutical products, especially parenteral drugs. Any sterile and/or pyrogen-free pharmaceutical product requires regulatory specifications to ensure safe patient use. This study covers the performance evaluation study of an endotoxin quantitation commercial kit by recombinant Factor C (rFC), Endozyme II® Go, for 0.9% sodium chloride injection. The samples were spiked with endotoxin solutions between 0.0005 and 10 EU/mL and tested by the rFC kit to evaluate precision, accuracy, detection and quantification limits, linearity, and robustness. Each of the six points was assayed at least five times.The relative standard deviation for precision testing ranged from 1.9 to 8.3%. The recovery accuracy values of endotoxin were between 61% and 125% for the range from 0.005 to 10 EU/mL. The results demonstrated that the rFC method allows endotoxin quantification with accuracy, precision, specificity, and linearity for the range of 0.005 and 10 EU/mL for 0.9% sodium chloride injection. (AU)


A contaminação por endotoxinas é uma ameaça à segurança dos produtos farmacêuticos, especialmente dos medicamentos parenterais. Qualquer produto farmacêutico estéril e/ou livre de pirogênios requer especificações regulatórias para garantir a segurança de uso para o paciente. Este estudo abrange o estudo de avaliação de desempenho empregando o kit comercial Endozyme II® Go para quantificação de endotoxina, por Fator C recombinante (FCr), em amostras de cloreto de sódio 0,9% para uso parenteral. As amostras foram fortificadas com cinco concentrações distintas de soluções de endotoxina na faixa entre 0,0005 e 10 UE/mL. Cada um dos cinco níveis foi testado pelo menos cinco vezes para avaliação dos critérios de precisão, exatidão, limites de detecção e quantificação, linearidade e robustez. O desvio padrão relativo para os testes de precisão variou de 1,9 a 8,3%. Os valores de recuperação de endotoxina para o parâmetro exatidão estiveram compreendidos entre 61% e 125%. Os resultados demonstraram que o método por FCr permite a quantificação de endotoxinas com exatidão, precisão, especificidade e linearidade para a faixa de 0,005 e 10 UE/mL em amostras de cloreto de sódio 0,9% para uso parenteral. (AU)


Subject(s)
In Vitro Techniques , Endotoxins , Saline Solution , Sodium Chloride
2.
Article in English | LILACS, CONASS, Coleciona SUS, Sec. Est. Saúde SP, SESSP-IALPROD, Sec. Est. Saúde SP | ID: biblio-1425867

ABSTRACT

The sterility test described in pharmacopoeial compendia requires a 14-day incubation period to obtain a valid analytical result. Therefore, the use of alternative methods to evaluate the sterility of pharmaceuticals, such as the BacT/Alert® 3D system, is particularly interesting, because it allows a reduced incubation period and lower associated costs. Considering that the BacT/Alert® 3D system offers several culture media formulations developed for this microbial detection system, the present study was aimed to evaluate and compare the performance of BacT/Alert® 3D with the pharmacopoeial sterility test. There was no significant difference between the ability of the culture media to allow detection of microbial contamination. However, the rapid sterility testing method allowed a more rapid detection of the challenge microorganisms, which indicates that the system is a viable alternative for assessing the sterility of injectable products.


Subject(s)
Adenosine Triphosphate , Infertility , Methods
3.
J Pharm Innov ; 13(1): 27-35, 2018.
Article in English | MEDLINE | ID: mdl-29497461

ABSTRACT

The sterility test described in pharmacopoeial compendia requires a 14-day incubation period to obtain a valid analytical result. Therefore, the use of alternative methods to evaluate the sterility of pharmaceuticals, such as the BacT/Alert® 3D system, is particularly interesting, because it allows a reduced incubation period and lower associated costs. Considering that the BacT/Alert® 3D system offers several culture media formulations developed for this microbial detection system, the present study was aimed to evaluate and compare the performance of BacT/Alert® 3D with the pharmacopoeial sterility test. There was no significant difference between the ability of the culture media to allow detection of microbial contamination. However, the rapid sterility testing method allowed a more rapid detection of the challenge microorganisms, which indicates that the system is a viable alternative for assessing the sterility of injectable products.

4.
J Pharm Innov ; 13(1)2018.
Article in English | LILACS, CONASS, Coleciona SUS, Sec. Est. Saúde SP, SESSP-IALPROD, Sec. Est. Saúde SP | ID: biblio-1426032

ABSTRACT

The sterility test described in pharmacopoeial compendia requires a 14-day incubation period to obtain a valid analytical result. Therefore, the use of alternative methods to evaluate the sterility of pharmaceuticals, such as the BacT/Alert® 3D system, is particularly interesting, because it allows a reduced incubation period and lower associated costs. Considering that the BacT/Alert® 3D system offers several culture media formulations developed for this microbial detection system, the present study was aimed to evaluate and compare the performance of BacT/Alert® 3D with the pharmacopoeial sterility test. There was no significant difference between the ability of the culture media to allow detection of microbial contamination. However, the rapid sterility testing method allowed a more rapid detection of the challenge microorganisms, which indicates that the system is a viable alternative for assessing the sterility of injectable products.


Subject(s)
Aptitude , Culture Media , Environmental Pollution , Infertility
5.
Curr Drug Deliv ; 14(7): 917-925, 2017.
Article in English | MEDLINE | ID: mdl-27919214

ABSTRACT

BACKGROUND: Many researches involving the development of new techniques and biomaterials to formulate a suitable drug delivery system and tissue engineering have been conducted. The majority of published literature from these researches emphasizes the production and materials characterization. The safety aspect of hydrogels and biomaterials is a major constraint in their biological applications. OBJECTIVE: The present review article aimed to summarize various literatures that encompass the difficulties encountered with decontamination and sterilization methods in the preparations of biomaterials and especially hydrogels for biological applications. METHOD: We searched for original and review articles from various indexed journals reporting applications of hydrogels and biomaterials in drug delivery systems and the importance of decontamination process for hydrogel containing preparations based on various patents evidences. RESULTS: Despite the vast literature available, limited information regarding the decontamination and sterilization processes related to hydrogels and biomaterials is reported. Sterilization processes to hydrogels are not yet fully explored. Researchers working on hydrogel based systems can consider decontamination of such biomaterial as an important tool to allow for commercialization within the chemical, herbal or pharmaceutical industries. CONCLUSION: Unfortunately, till date, limited papers are available which reported the challenges associated with decontamination methods to prepare hydrogels and biomaterials for biological applications. In conclusion, each case of biomaterial requires individual consideration to decontamination and/or sterilization. This must be submitted to a specific method, but more than one technique can be involved. Physicochemical and biological alterations must be avoided and evaluated by the appropriate assays method. Furthermore, it is also important to consider that each method must be validated depending upon the process variables.


Subject(s)
Anti-Infective Agents/administration & dosage , Decontamination/methods , Drug Delivery Systems , Hydrogels/administration & dosage , Animals , Biocompatible Materials
6.
Drug Deliv Transl Res ; 7(1): 66-76, 2017 02.
Article in English | MEDLINE | ID: mdl-27677866

ABSTRACT

The present study aimed to develop matrix-type transdermal drug delivery system (TDDS) of metoprolol tartrate using polyvinyl pyrrolidone (PVP) and polyvinyl alcohol (PVA). The transdermal films were evaluated for physical parameters, Fourier transform infrared spectroscopy analysis (FTIR), differential scanning calorimetry (DSC), in vitro drug release, in vitro skin permeability, skin irritation test and stability studies. The films were found to be tough, non-sticky, easily moldable and possess good tensile strength. As the concentration of PVA was increased, the tensile strength of the films was also increased. Results of FTIR spectroscopy and DSC revealed the absence of any drug-polymer interactions. In vitro release of metoprolol followed zero-order kinetics and the mechanism of release was found to be diffusion rate controlled. In vitro release studies of metoprolol using Keshary-Chein (vertical diffusion cell) indicated 65.5 % drug was released in 24 h. In vitro skin permeation of metoprolol transdermal films showed 58.13 % of the drug was released after 24 h. In vitro skin permeation of metoprolol followed zero-order kinetics in selected formulations. The mechanism of release was found to be diffusion rate controlled. In a 22-day skin irritation test, tested formulation of transdermal films did not exhibit any allergic reactions, inflammation, or contact dermatitis. The transdermal films showed good stability in the 180-day stability study. It can be concluded that the TDDS of MPT can help in bypassing the first-pass effect and will provide patient improved compliance, without sacrificing the therapeutic advantages of the drugs.


Subject(s)
Antihypertensive Agents/administration & dosage , Drug Delivery Systems , Metoprolol/administration & dosage , Skin/metabolism , Administration, Cutaneous , Animals , Antihypertensive Agents/chemistry , Calorimetry, Differential Scanning , Drug Liberation , Drug Stability , In Vitro Techniques , Metoprolol/chemistry , Polyvinyl Alcohol/chemistry , Povidone/chemistry , Rats , Skin Absorption , Skin Irritancy Tests , Spectroscopy, Fourier Transform Infrared
7.
Curr Pharm Des ; 22(27): 4264-87, 2016.
Article in English | MEDLINE | ID: mdl-27339428

ABSTRACT

BACKGROUND: The present review article provides an overview of the published literature concerning microbial quality of medicinal plants and products and their decontamination methods. It is important to analyze different aspects regarding the cultivation, growing, harvesting, storage, manufacturing, and decontamination of medicinal plant products. Herbal medicinal plants bear a massive microbial load leading to contamination and mycotoxin, which needs to be considered, and properly controlled using suitable sterilization and decontamination methods. METHODS: The main focus of this review is on the definition, advantages, disadvantages and applications of decontamination methods, particularly to show that one must consider the characteristics of the initial sample to be decontaminated. RESULTS: The effects of various methods (ozone, plasma, irradiation) on medicinal herbs and products treated for microbiological decontamination are dependent on factors related to microbial load (i.e., nature and amount of initial contamination), herb/product matrix (i.e., complexity of chemical composition, physical state - solid or liquid) and treatment conditions (i.e., time, irradiation dose, absence or presence of oxygen). In addition, it is important to accept some loss of the chemical compounds, while decreasing microbial load to acceptable limits according to official herbal pharmacopoeias and literature, thus ensuring a final product with quality, safety and therapeutic efficacy. CONCLUSION: The conclusion, which comes from this contribution, is that herbal medicine has more contaminants than a chemically welldefined drug, thus, good manufacturing practices should be followed.


Subject(s)
Drug Contamination , Herbal Medicine , Plant Extracts/chemistry , Plants, Medicinal/chemistry , Decontamination , Humans , Quality Control
8.
J AOAC Int ; 97(3): 908-12, 2014.
Article in English | MEDLINE | ID: mdl-25051642

ABSTRACT

Caspofungin is an echinocandin antifungal used in the treatment of invasive fungal infections. Several methods have been reported for the quantitative analysis of echinocandins; however, there is no microbiological assay for determination of caspofungin potency in the presence of its degradation products. This study aimed to develop and validate a microbiological method for quantitative analysis of caspofungin in lyophilized powder, evaluate the stability, and determinate the degradation kinetics of the drug when the finished product is submitted to heat stress. A procedure was established to estimate measurement uncertainty for routine analysis. The validation was performed as recommended in the current official guidelines. The agar diffusion method is based on the inhibitory effect of caspofungin on Candida albicans. Results showed selectivity, linearity, precision, and accuracy of the method. Statistical analysis demonstrated that method is linear (in the range 2.5 to 16 microg/mL, y= 15.73 + 6.4x, r2 = 0.9965), precise (intermediate precision: 2.54%), and accurate (recovery range: 95.01-102.46%). The proposed method allowed evaluation of the thermal stability of the drug at 80 degreesC for 120 min and determination of first order degradation kinetics. The variability of inhibition zone sizes was the most important source of uncertainty at about 87% of the overall uncertainty (103.0+/-1.7%). These results show that the proposed method is applicable to routine laboratory testing, and is sensitive to thermal degradation of caspofungin.


Subject(s)
Antifungal Agents/analysis , Echinocandins/analysis , Microbial Sensitivity Tests/methods , Caspofungin , Drug Stability , Echinocandins/chemistry , Lipopeptides , Uncertainty
9.
Braz. j. pharm. sci ; 49(2): 367-371, Apr.-June 2013. ilus, graf, tab
Article in English | LILACS | ID: lil-680648

ABSTRACT

The aim of this work is to present the two one-sided test (TOST) as an alternative approach to compare dissolution profiles of extended-release dosage forms. The dissolution profiles of oxycodone extended-release tablets containing 10 mg, 20 mg and 40 mg (reference and generic) were evaluated according to the requirements described in United States Pharmacopeia. These dissolution profiles were compared using the conventional similarity factor (f2) and the proposed TOST as an equivalence test. TOST is a simple and alternative approach to compare dissolution profiles of extended-release dosage forms. It allows us to identify the time-point (or time-points) that did not show similarity. We concluded that the two one-sided test performed at a significance level of 5% and defined as D = 10 showed results comparable to those obtained by the conventional similarity factor (f2).


O objetivo deste trabalho é apresentar o teste uni-caudal duplo (TOST) como uma abordagem alternativa na comparação do perfil de dissolução de formas farmacêuticas de liberação prolongada. Os perfis de dissolução de comprimidos de liberação prolongada de oxicodona contendo 10 mg, 20 mg e 40 mg (genérico e referência) foram avaliados de acordo com os requisitos descritos na Farmacopeia Americana. Estes perfis de dissolução foram comparados empregando-se o fator de semelhança convencional (f2) e o método TOST como teste de equivalência. TOST é uma abordagem simples e alternativa para a comparação de perfis de dissolução de formas farmacêuticas de liberação prolongada. Este permite identificar o ponto (ou pontos) que não apresentou semelhança. Considerando-se D = 10, concluímos que o teste uni-caudal duplo num nível de significância de 5% apresenta resultados comparáveis àqueles obtidos com o fator de semelhança convencional (f2).


Subject(s)
Dosage Forms/standards , Dissolution , Test Taking Skills/methods , Tablets/classification , Therapeutic Equivalency
10.
J AOAC Int ; 90(5): 1266-71, 2007.
Article in English | MEDLINE | ID: mdl-17955971

ABSTRACT

High-performance liquid chromatographic (LC) and ultraviolet derivative spectrophotometric (UVD) methods were developed and validated for the quantitative determination of epinastine hydrochloride in coated tablets. LC was performed on a reversed-phase RP-18 column with a mobile phase composed of 0.3% triethylamine (pH adjusted to 4.0 with 10% orthophosphoric acid)-methanol (60 + 40, v/v). The first-order derivative method was performed at 243.8 nm using HCI and methanol as the solvent. The methods were validated according to U.S. Pharmacopoeia and International Conference on Harmonization guidelines. The statistical analysis by Student's t-test showed no significant difference between the results obtained by the 2 methods. The proposed methods were found to be simple, rapid, precise, accurate, robust, and sensitive, allowing perfect interchange. The LC and UVD methods can be used in the routine quantitative determination of the epinastine hydrochloride in coated tablets.


Subject(s)
Chemistry, Pharmaceutical/methods , Chromatography, Liquid/instrumentation , Chromatography, Liquid/methods , Dibenzazepines/analysis , Histamine H1 Antagonists/analysis , Imidazoles/analysis , Spectrophotometry, Ultraviolet/methods , Chromatography, High Pressure Liquid/methods , Dosage Forms , Drug Stability , Hydrogen-Ion Concentration , Models, Chemical , Pharmaceutical Preparations/chemistry , Reference Standards , Reproducibility of Results , Tablets, Enteric-Coated , Technology, Pharmaceutical/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...