Cancers (Basel) ; 15(23)2023 Dec 01.
Article in English | MEDLINE | ID: mdl-38067386

ABSTRACT

PURPOSE: This systematic review aims to identify, evaluate, and summarize the findings of the literature on existing computational models for radiofrequency and microwave thermal liver ablation planning and compare their accuracy. METHODS: A systematic literature search was performed in the MEDLINE and Web of Science databases. Characteristics of the computational model and validation method of the included articles were retrieved. RESULTS: The literature search identified 780 articles, of which 35 were included. A total of 19 articles focused on simulating radiofrequency ablation (RFA) zones, and 16 focused on microwave ablation (MWA) zones. Out of the 16 articles simulating MWA, only 2 used in vivo experiments to validate their simulations. Out of the 19 articles simulating RFA, 10 articles used in vivo validation. Dice similarity coefficients describing the overlap between in vivo experiments and simulated RFA zones varied between 0.418 and 0.728, with mean surface deviations varying between 1.1 mm and 8.67 mm. CONCLUSION: Computational models to simulate ablation zones of MWA and RFA show considerable heterogeneity in model type and validation methods. It is currently unknown which model is most accurate and best suitable for use in clinical practice.

2.
Iran J Med Sci ; 47(5): 440-449, 2022 09.
Article in English | MEDLINE | ID: mdl-36117575

ABSTRACT

Background: Automated image segmentation is an essential step in quantitative image analysis. This study assesses the performance of a deep learning-based model for lung segmentation from computed tomography (CT) images of normal and COVID-19 patients. Methods: A descriptive-analytical study was conducted from December 2020 to April 2021 on the CT images of patients from various educational hospitals affiliated with Mashhad University of Medical Sciences (Mashhad, Iran). Of the selected images and corresponding lung masks of 1,200 confirmed COVID-19 patients, 1,080 were used to train a residual neural network. The performance of the residual network (ResNet) model was evaluated on two distinct external test datasets, namely the remaining 120 COVID-19 and 120 normal patients. Different evaluation metrics such as Dice similarity coefficient (DSC), mean absolute error (MAE), relative mean Hounsfield unit (HU) difference, and relative volume difference were calculated to assess the accuracy of the predicted lung masks. The Mann-Whitney U test was used to assess the difference between the corresponding values in the normal and COVID-19 patients. P<0.05 was considered statistically significant. Results: The ResNet model achieved a DSC of 0.980 and 0.971 and a relative mean HU difference of -2.679% and -4.403% for the normal and COVID-19 patients, respectively. Comparable performance in lung segmentation of normal and COVID-19 patients indicated the model's accuracy for identifying lung tissue in the presence of COVID-19-associated infections. Although a slightly better performance was observed in normal patients. Conclusion: The ResNet model provides an accurate and reliable automated lung segmentation of COVID-19 infected lung tissue.A preprint version of this article was published on arXiv before formal peer review (https://arxiv.org/abs/2104.02042).


Subject(s)
COVID-19 , COVID-19/diagnostic imaging , Humans , Lung/diagnostic imaging , Neural Networks, Computer , Thorax , Tomography, X-Ray Computed/methods
3.
Clin Nucl Med ; 46(8): 609-615, 2021 Aug 01.
Article in English | MEDLINE | ID: mdl-33661195

ABSTRACT

OBJECTIVE: This study evaluates the feasibility of direct scatter and attenuation correction of whole-body 68Ga-PSMA PET images in the image domain using deep learning. METHODS: Whole-body 68Ga-PSMA PET images of 399 subjects were used to train a residual deep learning model, taking PET non-attenuation-corrected images (PET-nonAC) as input and CT-based attenuation-corrected PET images (PET-CTAC) as target (reference). Forty-six whole-body 68Ga-PSMA PET images were used as an independent validation dataset. For validation, synthetic deep learning-based attenuation-corrected PET images were assessed considering the corresponding PET-CTAC images as reference. The evaluation metrics included the mean absolute error (MAE) of the SUV, peak signal-to-noise ratio, and structural similarity index (SSIM) in the whole body, as well as in different regions of the body, namely, head and neck, chest, and abdomen and pelvis. RESULTS: The deep learning-guided direct attenuation and scatter correction produced images of comparable visual quality to PET-CTAC images. It achieved an MAE, relative error (RE%), SSIM, and peak signal-to-noise ratio of 0.91 ± 0.29 (SUV), -2.46% ± 10.10%, 0.973 ± 0.034, and 48.171 ± 2.964, respectively, within whole-body images of the independent external validation dataset. The largest RE% was observed in the head and neck region (-5.62% ± 11.73%), although this region exhibited the highest value of SSIM metric (0.982 ± 0.024). The MAE (SUV) and RE% within the different regions of the body were less than 2.0% and 6%, respectively, indicating acceptable performance of the deep learning model. CONCLUSIONS: This work demonstrated the feasibility of direct attenuation and scatter correction of whole-body 68Ga-PSMA PET images in the image domain using deep learning with clinically tolerable errors. The technique has the potential of performing attenuation correction on stand-alone PET or PET/MRI systems.


Subject(s)
Deep Learning , Edetic Acid/analogs & derivatives , Image Processing, Computer-Assisted/methods , Oligopeptides , Positron-Emission Tomography , Scattering, Radiation , Feasibility Studies , Gallium Isotopes , Gallium Radioisotopes , Humans , Male , Tomography, X-Ray Computed