Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Br J Radiol ; 87(1040): 20130755, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24884727

ABSTRACT

OBJECTIVE: Assessment of myocardial function can be performed at higher noise levels than necessary for coronary arterial evaluation. We evaluated image quality and radiation exposure of a dose-conserving function-only acquisition vs retrospectively electrocardiogram(ECG)-gated coronary CTA with automatic tube current modulation. METHODS: Of 26 patients who underwent clinically indicated coronary CTA for coronary and function evaluation, 13 (Group I) underwent prospectively ECG-triggered coronary CTA, followed by low-dose retrospectively ECG-gated scan for function (128-slice dual-source, 80 kVp; reference tube current, 100 mA; 8-mm-thick multiplanar reformatted reconstructions) performed either immediately (n = 6) or after 5- to 10-min delay for infarct assessment (n = 7). 13 corresponding controls (Group II) underwent retrospectively ECG-gated protocols (automatic tube potential selection with CARE kV/CARE Dose 4D; Siemens Healthcare, Forchheim, Germany) with aggressive dose modulation. Image quality assessment was performed on the six Group I subjects who underwent early post-contrast dedicated function scan and corresponding controls. Radiation exposure was based on dose-length product. RESULTS: Contrast-to-noise ratio (CNR) was preserved throughout the cardiac cycle in Group I and varied according to dose modulation in Group II. Visual image quality indices were similar during end systole but were better in Group II at end diastole. Although the total radiation exposure was equivalent in Group I and Group II (284 vs 280 mGy cm), the median radiation exposure associated with only the dedicated function scan was 138 mGy cm (interquartile range, 116-203 mGy cm). CONCLUSION: A low-dose retrospective ECG-gated protocol permits assessment of myocardial function at a median radiation exposure of 138 mGy cm and offers more consistent multiphase CNR vs traditional ECG-modulation protocols. This is useful for pure functional evaluation or as an adjunct to single-phase scan modes. ADVANCES IN KNOWLEDGE: Radiation exposure can be limited with a tailored myocardial function CT protocol while maintaining preserved images.


Subject(s)
Cardiac-Gated Imaging Techniques/methods , Coronary Angiography/methods , Heart Diseases/diagnostic imaging , Tomography, X-Ray Computed/methods , Contrast Media , Electrocardiography , Feasibility Studies , Female , Heart Diseases/physiopathology , Humans , Male , Middle Aged , Prospective Studies , Radiation Dosage , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...