1.
J Interv Card Electrophysiol ; 28(3): 221-5, 2010 Sep.
Article in English | MEDLINE | ID: mdl-19636687

ABSTRACT

Patients implanted with left ventricular assist devices (LVAD) may have implantable cardioverter defibrillators (ICD) implanted for sudden cardiac death prevention. This opens the possibility of device-device communication interactions and thus interferences. We present a case of such interaction that led to ICD communication failure following the activation of an LVAD. In this paper, we describe a practical solution to circumvent the communication interference and review the communication links of ICDs and possible mechanisms of ICD-LVAD interactions.


Subject(s)
Defibrillators, Implantable/adverse effects , Electromagnetic Fields , Heart-Assist Devices/adverse effects , Telemetry , Equipment Design , Equipment Failure Analysis , Humans , Male , Middle Aged , Shock, Cardiogenic/etiology
2.
Heart Rhythm ; 4(9): 1165-9, 2007 Sep.
Article in English | MEDLINE | ID: mdl-17765615

ABSTRACT

BACKGROUND: The outcomes of patients with ventricular assist devices (VADs) who undergo catheter ablation for ventricular tachycardia (VT) have not been reported. OBJECTIVE: The purpose of this study was to assess the feasibility, safety, and efficacy of endocardial VT ablation in patients with VADs. METHODS: We retrospectively reviewed three cases at our institution where endocardial catheter ablation was performed in patients with VADs and incessant VT. RESULTS: Three patients with underlying cardiomyopathies and VADs underwent VT ablation for incessant VT refractory to multiple antiarrhythmic medications. In each case, VT was either eliminated or significantly ameliorated by catheter ablation. No procedure-related complications occurred. The hemodynamic stability afforded by the VAD played an important role in facilitating ablation in two of the cases. CONCLUSION: Catheter ablation for VT in VAD patients appears to be feasible, safe, and effective based on our initial experience. Several technical issues, such as decreases in ventricular volumes that can limit maneuverability of the ablation catheter and potential entrapment of the mapping catheter in the inflow cannula, need to be considered at the time of ablation.


Subject(s)
Catheter Ablation/methods , Heart-Assist Devices , Tachycardia, Ventricular/surgery , Adult , Aged , Cardiac Volume , Electrocardiography , Fatal Outcome , Feasibility Studies , Humans , Male , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/physiopathology , Treatment Outcome