1.
Clin Oncol (R Coll Radiol) ; 36(2): 119-127, 2024 02.
Article in English | MEDLINE | ID: mdl-38042669

ABSTRACT

AIMS: Cardiac disease is a dose-limiting toxicity in non-small cell lung cancer radiotherapy. The dose to the heart base has been associated with poor survival in multiple institutional and clinical trial datasets using unsupervised, voxel-based analysis. Validation has not been undertaken in a cohort with individual patient delineations of the cardiac base or for the endpoint of cardiac events. The purpose of this study was to assess the association of heart base radiation dose with overall survival and the risk of cardiac events with individual heart base contours. MATERIALS AND METHODS: Patients treated between 2015 and 2020 were reviewed for baseline patient, tumour and cardiac details and both cancer and cardiac outcomes as part of the NI-HEART study. Three cardiologists verified cardiac events including atrial fibrillation, heart failure and acute coronary syndrome. Cardiac substructure delineations were completed using a validated deep learning-based autosegmentation tool and a composite cardiac base structure was generated. Cox and Fine-Gray regressions were undertaken for the risk of death and cardiac events. RESULTS: Of 478 eligible patients, most received 55 Gy/20 fractions (96%) without chemotherapy (58%), planned with intensity-modulated radiotherapy (71%). Pre-existing cardiovascular morbidity was common (78% two or more risk factors, 46% one or more established disease). The median follow-up was 21.1 months. Dichotomised at the median, a higher heart base Dmax was associated with poorer survival on Kaplan-Meier analysis (20.2 months versus 28.3 months; hazard ratio 1.40, 95% confidence interval 1.14-1.75, P = 0.0017) and statistical significance was retained in multivariate analyses. Furthermore, heart base Dmax was associated with pooled cardiac events in a multivariate analysis (hazard ratio 1.75, 95% confidence interval 1.03-2.97, P = 0.04). CONCLUSIONS: Heart base Dmax was associated with the rate of death and cardiac events after adjusting for patient, tumour and cardiovascular factors in the NI-HEART study. This validates the findings from previous unsupervised analytical approaches. The heart base could be considered as a potential sub-organ at risk towards reducing radiation cardiotoxicity.


Subject(s)
Carcinoma, Non-Small-Cell Lung , Heart Diseases , Lung Neoplasms , Radiotherapy, Intensity-Modulated , Humans , Carcinoma, Non-Small-Cell Lung/pathology , Lung Neoplasms/pathology , Heart , Radiotherapy, Intensity-Modulated/adverse effects , Heart Diseases/epidemiology , Heart Diseases/etiology , Radiation Dosage
2.
Phys Med ; 33: 182-188, 2017 Jan.
Article in English | MEDLINE | ID: mdl-28108101

ABSTRACT

Computational anthropomorphic phantoms have become an important investigation tool for medical imaging and dosimetry for radiotherapy and radiation protection. The development of computational phantoms with realistic anatomical features contribute significantly to the development of novel methods in medical physics. For many applications, it is desirable that such computational phantoms have a real-world physical counterpart in order to verify the obtained results. In this work, we report the development of a voxelised phantom, the HIGH_RES_HEAD, modelling a paediatric head based on the commercial phantom 715-HN (CIRS). HIGH_RES_HEAD is unique for its anatomical details and high spatial resolution (0.18×0.18mm2 pixel size). The development of such a phantom was required to investigate the performance of a new proton computed tomography (pCT) system, in terms of detector technology and image reconstruction algorithms. The HIGH_RES_HEAD was used in an ad-hoc Geant4 simulation modelling the pCT system. The simulation application was previously validated with respect to experimental results. When compared to a standard spatial resolution voxelised phantom of the same paediatric head, it was shown that in pCT reconstruction studies, the use of the HIGH_RES_HEAD translates into a reduction from 2% to 0.7% of the average relative stopping power difference between experimental and simulated results thus improving the overall quality of the head phantom simulation. The HIGH_RES_HEAD can also be used for other medical physics applications such as treatment planning studies. A second version of the voxelised phantom was created that contains a prototypic base of skull tumour and surrounding organs at risk.


Subject(s)
Phantoms, Imaging , Tomography, X-Ray Computed/instrumentation , Head , Humans , Monte Carlo Method , Protons
3.
Med Phys ; 43(12): 6291, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27908179

ABSTRACT

PURPOSE: To evaluate the spatial resolution of proton CT using both a prototype proton CT scanner and Monte Carlo simulations. METHODS: A custom cylindrical edge phantom containing twelve tissue-equivalent inserts with four different compositions at varying radial displacements from the axis of rotation was developed for measuring the modulation transfer function (MTF) of a prototype proton CT scanner. Two scans of the phantom, centered on the axis of rotation, were obtained with a 200 MeV, low-intensity proton beam: one scan with steps of 4°, and one scan with the phantom continuously rotating. In addition, Monte Carlo simulations of the phantom scan were performed using scanners idealized to various degrees. The data were reconstructed using an iterative projection method with added total variation superiorization based on individual proton histories. Edge spread functions in the radial and azimuthal directions were obtained using the oversampling technique. These were then used to obtain the modulation transfer functions. The spatial resolution was defined by the 10% value of the modulation transfer function (MTF10%) in units of line pairs per centimeter (lp/cm). Data from the simulations were used to better understand the contributions of multiple Coulomb scattering in the phantom and the scanner hardware, as well as the effect of discretization of proton location. RESULTS: The radial spatial resolution of the prototype proton CT scanner depends on the total path length, W, of the proton in the phantom, whereas the azimuthal spatial resolution depends both on W and the position, u-, at which the most-likely path uncertainty is evaluated along the path. For protons contributing to radial spatial resolution, W varies with the radial position of the edge, whereas for protons contributing to azimuthal spatial resolution, W is approximately constant. For a pixel size of 0.625 mm, the radial spatial resolution of the image reconstructed from the fully idealized simulation data ranged between 6.31 ± 0.36 lp/cm for W = 197 mm i.e., close to the center of the phantom, and 13.79 ± 0.36 lp/cm for W = 97 mm, near the periphery of the phantom. The azimuthal spatial resolution ranged from 6.99 ± 0.23 lp/cm at u- = 75 mm (near the center) to 11.20 ± 0.26 lp/cm at u- = 20 mm (near the periphery). Multiple Coulomb scattering limits the radial spatial resolution for path lengths greater than approximately 130 mm, and the azimuthal spatial resolution for positions of evaluation greater than approximately 40 mm for W = 199 mm. The radial spatial resolution of the image reconstructed from data from the 4° stepped experimental scan ranged from 5.11 ± 0.61 lp/cm for W = 197 mm to 8.58 ± 0.50 lp/cm for W = 97 mm. In the azimuthal direction, the spatial resolution ranged from 5.37 ± 0.40 lp/cm at u- = 75 mm to 7.27 ± 0.39 lp/cm at u- = 20 mm. The continuous scan achieved the same spatial resolution as that of the stepped scan. CONCLUSIONS: Multiple Coulomb scattering in the phantom is the limiting physical factor of the achievable spatial resolution of proton CT; additional loss of spatial resolution in the prototype system is associated with scattering in the proton tracking system and inadequacies of the proton path estimate used in the iterative reconstruction algorithm. Improvement in spatial resolution may be achievable by improving the most likely path estimate by incorporating information about high and low density materials, and by minimizing multiple Coulomb scattering in the proton tracking system.


Subject(s)
Protons , Signal-To-Noise Ratio , Tomography Scanners, X-Ray Computed , Monte Carlo Method , Phantoms, Imaging
4.
Nucl Instrum Methods Phys Res A ; 831: 394-399, 2016 Sep 21.
Article in English | MEDLINE | ID: mdl-27818559

ABSTRACT

We report on the operation and performance tests of a preclinical head scanner developed for proton computed tomography (pCT). After extensive preclinical testing, pCT is intended to be employed in support of proton therapy treatment planning and pre-treatment verification in patients undergoing particle-beam therapy. In order to assess the performance of the scanner, we have performed CT scans with 200 MeV protons from both the synchrotron of the Loma Linda University Medical Center (LLUMC) and the cyclotron of the Northwestern Medicine Chicago Proton Center (NMCPC). The very high sustained rate of data acquisition, exceeding one million protons per second, allowed a full 360° scan to be completed in less than 7 minutes. The reconstruction of various phantoms verified accurate reconstruction of the proton relative stopping power (RSP) and the spatial resolution in a variety of materials. The dose for an image with better than 1% uncertainty in the RSP is found to be close to 1 mGy.

5.
Med Phys ; 43(2): 664-74, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26843230

ABSTRACT

PURPOSE: Proton computed tomography (pCT) will enable accurate prediction of proton and ion range in a patient while providing the benefit of lower radiation exposure than in x-ray CT. The accuracy of the range prediction is essential for treatment planning in proton or ion therapy and depends upon the detector used to evaluate the water-equivalent path length (WEPL) of a proton passing through the object. A novel approach is presented for an inexpensive WEPL detector for pCT and proton radiography. METHODS: A novel multistage detector with an aperture of 10 × 37.5 cm was designed to optimize the accuracy of the WEPL measurements while simplifying detector construction and the performance requirements of its components. The design of the five-stage detector was optimized through simulations based on the geant4 detector simulation toolkit, and the fabricated prototype was calibrated in water-equivalent millimeters with 200 MeV protons in the research beam line of the clinical proton synchrotron at Loma Linda University Medical Center. A special polystyrene step phantom was designed and built to speed up and simplify the calibration procedure. The calibrated five-stage detector was tested in the 200 MeV proton beam as part of the pCT head scanner, using a water phantom and polystyrene slabs to verify the WEPL reconstruction accuracy. RESULTS: The beam-test results demonstrated excellent performance of the new detector, in good agreement with the simulation results. The WEPL measurement accuracy is about 3.0 mm per proton in the 0-260 mm WEPL range required for a pCT head scan with a 200 MeV proton beam. CONCLUSIONS: The new multistage design approach to WEPL measurements for proton CT and radiography has been prototyped and tested. The test results show that the design is competitive with much more expensive calorimeter and range-counter designs.


Subject(s)
Protons , Scintillation Counting/instrumentation , Tomography, X-Ray Computed/instrumentation , Calibration , Equipment Design , Uncertainty
6.
Nat Nanotechnol ; 6(3): 147-50, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21278752

ABSTRACT

Two-dimensional materials are attractive for use in next-generation nanoelectronic devices because, compared to one-dimensional materials, it is relatively easy to fabricate complex structures from them. The most widely studied two-dimensional material is graphene, both because of its rich physics and its high mobility. However, pristine graphene does not have a bandgap, a property that is essential for many applications, including transistors. Engineering a graphene bandgap increases fabrication complexity and either reduces mobilities to the level of strained silicon films or requires high voltages. Although single layers of MoS(2) have a large intrinsic bandgap of 1.8 eV (ref. 16), previously reported mobilities in the 0.5-3 cm(2) V(-1) s(-1) range are too low for practical devices. Here, we use a halfnium oxide gate dielectric to demonstrate a room-temperature single-layer MoS(2) mobility of at least 200 cm(2) V(-1) s(-1), similar to that of graphene nanoribbons, and demonstrate transistors with room-temperature current on/off ratios of 1 × 10(8) and ultralow standby power dissipation. Because monolayer MoS(2) has a direct bandgap, it can be used to construct interband tunnel FETs, which offer lower power consumption than classical transistors. Monolayer MoS(2) could also complement graphene in applications that require thin transparent semiconductors, such as optoelectronics and energy harvesting.


Subject(s)
Disulfides/chemistry , Molybdenum/chemistry , Nanostructures/chemistry , Nanotechnology/instrumentation , Semiconductors/instrumentation , Transistors, Electronic , Equipment Design , Graphite/chemistry , Microscopy, Atomic Force/methods , Nanotechnology/methods , Nanotubes, Carbon/chemistry , Silicon/chemistry , Silicon Dioxide/chemistry , Surface Properties , Temperature