Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Anesthesiology ; 92(5): 1237-41, 2000 May.
Article in English | MEDLINE | ID: mdl-10781267

ABSTRACT

BACKGROUND: The authors compared airway management in normogravity and simulated microgravity with and without restraints for laryngoscope-guided tracheal intubation, the cuffed oropharyngeal airway, the standard laryngeal mask airway, and the intubating laryngeal mask airway. METHODS: Four trained anesthesiologist-divers participated in the study. Simulated microgravity during spaceflight was obtained using a submerged, full-scale model of the International Space Station Life Support Module and neutrally buoyant equipment and personnel. Customized, full-torso manikins were used for performing airway management. Each anesthesiologist-diver attempted airway management on 10 occasions with each device in three experimental conditions: (1) with the manikin at the poolside (poolside); (2) with the submerged manikin floating free (free-floating); and (3) with the submerged manikin fixed to the floor using a restraint (restrained). Airway management failure was defined as failed insertion after three attempts or inadequate device placement after insertion. RESULTS: For the laryngoscope-guided tracheal intubation, airway management failure occurred more frequently in the free-floating (85%) condition than the restrained (8%) and poolside (0%) conditions (both, P < 0.001). Airway management failure was similar among conditions for the cuffed oropharyngeal airway (poolside, 10%; free-floating, 15%; restrained, 15%), laryngeal mask airway (poolside, 0%; free-floating, 3%; restrained, 0%), and intubating laryngeal mask airway (poolside, 5%; free-floating, 5%; restrained, 10%). Airway management failure for the laryngoscope-guided tracheal intubation was usually caused by failed insertion (> 90%), and for the cuffed oropharyngeal airway, laryngeal mask airway, and intubating laryngeal mask airway, it was always a result of inadequate placement. CONCLUSION: The emphasis placed on the use of restraints for conventional tracheal intubation in microgravity is appropriate. Extratracheal airway devices may be useful when restraints cannot be applied or intubation is difficult.


Subject(s)
Aerospace Medicine/methods , Intubation, Intratracheal/instrumentation , Laryngeal Masks , Laryngoscopy , Adult , Gravitation , Humans , Intubation, Intratracheal/methods , Male , Manikins
SELECTION OF CITATIONS
SEARCH DETAIL
...