Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 25
Filter
1.
5.
Dysphagia ; 34(6): 939-941, 2019 12.
Article in English | MEDLINE | ID: mdl-31363845

ABSTRACT

We report a case of an uncommon type of dysphagia, due to esophagus compression by an aberrant right subclavian artery. This condition, known as dysphagia lusoria, was first recorded in 1787 by London physician David Bayford.


Subject(s)
Deglutition Disorders/etiology , Subclavian Artery/abnormalities , Aged , Deglutition Disorders/diagnosis , Deglutition Disorders/diagnostic imaging , Deglutition Disorders/pathology , Esophagus/diagnostic imaging , Esophagus/pathology , Female , Humans , Subclavian Artery/pathology , Tomography, X-Ray Computed
6.
Front Surg ; 4: 46, 2017.
Article in English | MEDLINE | ID: mdl-28884115

ABSTRACT

Civilian injuries are increasing according to the World Health Organization, and this is attributed mainly to road traffic accidents and urban interpersonal violence. Vascular injuries are common in these scenarios and are associated with high morbidity and mortality rates. Associated peripheral venous trauma is less likely to lead to death and controversy remains whether ligation or repair should be the primary approach. Conversely, non-compressible truncal venous insult can be lethal due to exsanguination, thus a high index of suspicion is crucial. Operative management is demanding with fair results but recent endovascular adjuncts demonstrate promising results and seem to be the way forward for these serious conditions.

7.
Front Surg ; 3: 29, 2016.
Article in English | MEDLINE | ID: mdl-27303669

ABSTRACT

Ultrasound (US) is a well-established screening tool for detection of abdominal aortic aneurysms (AAAs) and is currently recommended not only for those with a relevant family history but also for all men and high-risk women older than 65 years of age. The advent of minimally invasive endovascular techniques in the treatment of AAAs [endovascular aneurysm repair (EVAR)] has increased the need for repeat imaging, especially in the postoperative period. Nevertheless, preoperative planning, intraoperative execution, and postoperative surveillance all mandate accurate imaging. While computed tomographic angiography and angiography have dominated the field, repeatedly exposing patients to the deleterious effects of cumulative radiation and intravenous nephrotoxic contrast, US technology has significantly evolved over the past decade. In addition to standard color duplex US, 2D, 3D, or 4D contrast-enhanced US modalities are revolutionizing AAA management and postoperative surveillance. This technology can accurately measure AAA diameter and volume, and most importantly, it can detect endoleaks post-EVAR with high sensitivity and specificity. 4D contrast-enhanced US can even provide hemodynamic information about the branch vessels following fenestrated EVARs. The need for experienced US operators and accredited vascular labs is mandatory to guarantee the reliability of the results. This review article presents a comprehensive overview of the literature on the state-of-art US imaging in AAA management, including post-EVAR follow-up, techniques, and diagnostic accuracy.

8.
Ann Vasc Surg ; 29(3): 457-69, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25591487

ABSTRACT

BACKGROUND: The effect of carotid artery stenting (CAS) on cognitive function in patients with extracranial carotid artery stenosis is equivocal. The aim of this study was to examine the impact of CAS on various domains of cognitive function. METHODS: We performed a meta-analysis of the studies evaluating various domains of cognitive function before and after CAS, namely, (1) global cognition using Mini-Mental State Examination (MMSE) and Rey Auditory Verbal Learning Test (RAVLT), (2) executive function using Trail Making Test (TMT) A or Color Trails Test (CTT) A and TMT B or CTT B, (3) language ability using Boston Naming Test (BNT), (4) memory, (5) attention/psychomotor speed, and (6) functional ability, using various cognitive tests. Pooled weighted mean differences (WMDs) and standardized mean differences (SMDs) with 95% confidence intervals (95% CIs) were appropriately calculated using fixed or random effects models after assessing between-study heterogeneity. Meta-regression analysis was performed with number of patients per study; mean age (years); follow-up (months); proportion of men; proportion of patients with hypertension, diabetes mellitus, hyperlipidemia, smoking, and coronary artery disease; proportion of symptomatic patients; and degree of ipsilateral and degree of contralateral carotid stenosis as covariates. RESULTS: Sixteen studies were eligible, including a total of 626 CAS patients. A statistically significant improvement of global cognition was detected with MMSE (WMD = 0.67, 95% CI = 0.29-1.05, P < 0.001; follow-up = 5.6 months), but not with RAVLT (SMD = 0.45, 95% CI = -0.03 to 0.93, P = 0.07; follow-up = 2.4 months). Significant improvement of memory (SMD = 0.33, 95% CI = 0.11-0.55, P < 0.01; follow-up = 4.1 months) and attention/psychomotor speed (SMD = 0.21, 95% CI = 0.04-0.39, P = 0.02; follow-up = 4 months) was also detected. No statistically significant effect on executive function (TMT A/CTT A and TMT B/CTT B; SMD = 0.08, 95% CI = -0.10 to 0.26, P = 0.39; follow-up = 3.9 months and SMD = -0.02, 95% CI = -0.20 to 0.16, P = 0.82, respectively; follow-up = 3.9 months), language ability (BNT; SMD = 0.24, 95% CI = -0.05 to 0.54, P = 0.10; follow-up = 4 months), and functional ability (SMD = -0.05, 95% CI = -0.25 to 0.15, P = 0.63; follow-up = 3.8 months) was observed. No significant effects of the examined covariates were demonstrated in the meta-regression analyses. CONCLUSIONS: CAS may be associated with improvement in global cognition, memory, and attention/psychomotor speed. There was no positive effect on executive function, language, and functional ability, but CAS was not associated with a decline in any area of cognitive function. Future studies in larger groups of patients are probably needed to fully investigate the long-term effect of CAS on cognition in patients with carotid artery stenosis.


Subject(s)
Angioplasty/instrumentation , Carotid Stenosis/therapy , Cognition Disorders/etiology , Cognition , Stents , Aged , Attention , Carotid Stenosis/complications , Carotid Stenosis/diagnosis , Carotid Stenosis/psychology , Cognition Disorders/diagnosis , Cognition Disorders/psychology , Executive Function , Female , Humans , Male , Memory , Middle Aged , Neuropsychological Tests , Psychomotor Performance , Recovery of Function , Time Factors , Treatment Outcome , Verbal Behavior
9.
Curr Vasc Pharmacol ; 13(2): 239-47, 2015.
Article in English | MEDLINE | ID: mdl-23790064

ABSTRACT

OBJECTIVE: To evaluate the impact of statins on carotid restenosis (CR) >50% and future cardiovascular events (CVE), in patients undergoing carotid endarterectomy (CEA). METHODS: 570 consecutive patients (656 CEAs) operated between 1990 and 2009, were included in this retrospective study. The study cohort was followed for an average of 82 months (median 80, range 12- 180 months). Endpoints were the development of CR >50%, the occurrence of CVE (myocardial infarction, stroke) and overall mortality. Kaplan-Meier curves and Cox regression models were used to assess outcomes. RESULTS: 92 restenosis events were recorded. Freedom from restenosis >50% at 5, 10 and 15 years of follow-up was 92, 82 and 69%, respectively. Compared with statin-receivers, statin-free patients had a significantly higher 15-year restenosis rate (41 vs 10%; P = .001), a significantly higher CVE rate (49 vs 14%; P = .001) and a significantly higher mortality rate (24 vs 18%; P = .034). Adjusting for other covariates statins were independently associated with lower restenosis rate (hazard ratio [HR], 0.52; 95% CI, 0.31-0.88; P= .016), cardiovascular events (HR, 0.40; 95% CI, 0.26-0.61; P < 0.001) and long-term mortality (HR, 0.56; 95% CI, 0.33-0.95; P = .032). CONCLUSION: Statins not only reduce cardiovascular events and mortality but may also have an important effect on the anatomic durability of CEA. These data support the use of statins in patients with carotid stenosis undergoing CEA.


Subject(s)
Carotid Stenosis/surgery , Endarterectomy, Carotid , Hydroxymethylglutaryl-CoA Reductase Inhibitors/therapeutic use , Aged , Asymptomatic Diseases , Carotid Stenosis/complications , Carotid Stenosis/diagnosis , Carotid Stenosis/mortality , Chi-Square Distribution , Disease-Free Survival , Endarterectomy, Carotid/adverse effects , Endarterectomy, Carotid/mortality , Female , Humans , Kaplan-Meier Estimate , Logistic Models , Male , Middle Aged , Multivariate Analysis , Myocardial Infarction/etiology , Myocardial Infarction/mortality , Myocardial Infarction/prevention & control , Proportional Hazards Models , Recurrence , Retrospective Studies , Risk Factors , Stroke/etiology , Stroke/mortality , Stroke/prevention & control , Time Factors , Treatment Outcome
11.
Vasc Endovascular Surg ; 48(7-8): 476-81, 2014.
Article in English | MEDLINE | ID: mdl-25480667

ABSTRACT

A total of 22 patients with ruptured abdominal aortic aneurysms (rAAAs) after previous endovascular aortic repair (EVAR; rAAAevar) were presented to 7 referral hospitals in Greece, between January 2006 and April 2012. Type Ia endoleak and endograft migration were identified in 72.7% and 50%, respectively. Compliance to follow-up protocol prior to rupture was 31.8%. In-hospital mortality was 36.4% (9.1% for those treated with secondary EVAR and 63.6% for those treated with open surgical repair, P = .02). An increase in the proportion of patients with rAAAevar among the total number of patients with rAAAs from 1.3% in 2007 to 18.2% in 2012 (P for trend = .04) was recorded, corresponding to an annual increase of 2.8% (b = 2.84, P = .04). Rupture after EVAR seemed to be a clinical entity encountered with increasing frequency over the past years. Type I endoleak and endograft migration were most frequently observed, whereas compliance to follow-up was low.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Aortic Rupture/etiology , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/complications , Aortic Aneurysm, Abdominal/diagnosis , Aortic Aneurysm, Abdominal/mortality , Aortic Rupture/diagnosis , Aortic Rupture/mortality , Aortography/methods , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Databases, Factual , Endoleak/etiology , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Female , Foreign-Body Migration/etiology , Greece , Hospital Mortality , Humans , Male , Patient Compliance , Prosthesis Design , Retrospective Studies , Risk Factors , Stents , Time Factors , Tomography, X-Ray Computed , Treatment Outcome
12.
J Vasc Surg ; 60(5): 1140-1145, 2014 Nov.
Article in English | MEDLINE | ID: mdl-24953900

ABSTRACT

OBJECTIVE: The objective of this study was to evaluate the impact of contrast medium volume, inferior mesenteric artery (IMA) patency, and pre-existing as well as new-onset thrombus on the inflammatory response after elective endovascular aneurysm repair (EVAR). METHODS: The study included 87 patients undergoing elective endovascular repair of asymptomatic infrarenal aneurysms between January 2011 and November 2011. The patency of the IMA was determined by preoperative computed tomography angiography; the volume of the contrast medium used during the procedure was measured, and the volumes of chronic mural as well as new-onset thrombus were calculated from the preoperative and postoperative computed tomography angiograms with dedicated imaging software. The results were correlated to the occurrence of postimplantation syndrome (PIS) as well as to the main clinical and laboratory components of PIS: fever; increased white blood cell (WBC) count and C-reactive protein (CRP) level; decreased platelet count; and increased interleukin (IL)-6, IL-8, and IL-10 levels. RESULTS: Postoperatively, a statistically significant increase was recorded in the mean values of body temperature, WBCs, CRP, IL-6, IL-8, and IL-10, and a statistically significant decrease was recorded in the number of platelets. After adjustment for endograft type, the volume of new-onset thrombus was found to be significantly correlated with the peak postoperative temperature (ß = .307; P < .05) and the increase in WBC count (ß = .271; P < .05), CRP level (ß = .484; P < .001), and IL-6 level (ß = .288; P < .05). On the contrary, the volume of chronic mural thrombus, the patency of the IMA, and the volume of contrast medium were not found to significantly affect any parameter of the PIS. PIS occurred in 34 patients (39%). Multiple logistic regression analysis showed that both the volume of new-onset thrombus and the type of endograft were independently associated with the development of PIS. CONCLUSIONS: The volume of new-onset thrombus is associated with the development of PIS after EVAR, whereas chronic mural thrombus appears to be an inert material. IMA patency and contrast medium volume are irrelevant to the inflammatory response after EVAR.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Systemic Inflammatory Response Syndrome/etiology , Thrombosis/etiology , Aged , Aortic Aneurysm, Abdominal/diagnosis , Aortic Aneurysm, Abdominal/physiopathology , Aortography/methods , Biomarkers/blood , Body Temperature Regulation , Contrast Media , Elective Surgical Procedures , Female , Fever/etiology , Fever/physiopathology , Humans , Inflammation Mediators/blood , Leukocyte Count , Male , Mesenteric Artery, Inferior/diagnostic imaging , Mesenteric Artery, Inferior/physiopathology , Platelet Count , Predictive Value of Tests , Risk Factors , Systemic Inflammatory Response Syndrome/blood , Systemic Inflammatory Response Syndrome/diagnosis , Systemic Inflammatory Response Syndrome/physiopathology , Thrombosis/diagnostic imaging , Thrombosis/physiopathology , Tomography, X-Ray Computed , Treatment Outcome , Vascular Patency
13.
Ann Vasc Surg ; 28(6): 1384-90, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24517989

ABSTRACT

BACKGROUND: Endovascular aortic repair (EVAR) is being used with increasing frequency for the treatment of ruptured abdominal aortic aneurysms (rAAAs), although conflicting results have been reported concerning perioperative mortality. The aim of our study was to evaluate potential difference in mortality rates between EVAR and open surgical repair (OSR) and identify independent risk factors for in-hospital mortality in rAAAs. This study also aimed to evaluate the Glasgow Aneurysm Score (GAS) in predicting in-hospital mortality. A time-trend analysis of EVAR for ruptured AAAs was also performed. METHODS: Prospectively collected data from 7 public hospitals in Greece concerning rAAA repairs between January 2006 and April 2012 were analyzed. Primary outcome was in-hospital mortality. Multivariate logistic regression analysis was used to identify independent risk factors. The receiver-operator characteristic curve was used to determine the value of the GAS in predicting in-hospital death. Time-trend analysis, depicting annual changes (%), concerning EVAR for ruptured AAAs was also conducted. RESULTS: A total of 418 patients (92.3% men, mean age = 74.3 ± 8.8) with rAAAs were recorded during the study period. Among them, 113 patients (27%) underwent EVAR. Overall in-hospital mortality was 45.2%, whereas in-hospital mortality after EVAR and OSR was 20.4% and 54.3%, respectively (P < 0.001). Multivariate analysis evidenced that hemodynamic instability (P < 0.001), OSR (P < 0.001), age ≥80 years (P < 0.001), coronary artery disease (P < 0.001), and renal insufficiency (P = 0.02) independently increased in-hospital mortality. Area under the curve of GAS was 0.80 (95% confidence interval [CI] = 0.75-0.85, P < 0.001) for OSR and 0.64 (95% CI = 0.51-0.77, P = 0.04) for EVAR. Annual increase of proportion (%) of EVAR for rupture was 5% (P = 0.004). CONCLUSIONS: EVAR is being used with increasing frequency for the treatment of rAAAs and it appears to be associated with lower in-hospital mortality compared with OSR, after adjustment for hemodynamic instability and known atherosclerotic risk factors. Preoperative predictors of in-hospital mortality such as GAS should be probably modified in these patients.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Aortic Rupture/surgery , Blood Vessel Prosthesis Implantation/mortality , Endovascular Procedures/mortality , Hospital Mortality , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnosis , Aortic Aneurysm, Abdominal/mortality , Aortic Aneurysm, Abdominal/physiopathology , Aortic Rupture/diagnosis , Aortic Rupture/mortality , Aortic Rupture/physiopathology , Area Under Curve , Blood Vessel Prosthesis Implantation/adverse effects , Chi-Square Distribution , Databases, Factual , Decision Support Techniques , Endovascular Procedures/adverse effects , Female , Greece , Hemodynamics , Hospitals, Public , Humans , Logistic Models , Male , Multivariate Analysis , Odds Ratio , Predictive Value of Tests , ROC Curve , Risk Factors , Time Factors , Treatment Outcome
14.
Ann Vasc Surg ; 28(5): 1197-203, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24333197

ABSTRACT

BACKGROUND: Internal carotid artery (ICA) occlusion is associated with acute stroke and carries significant morbidity and mortality. The aim of this study was to examine whether ultrasonographic carotid plaque type may be associated with ICA occlusion. METHODS: Two hundred eleven patients (85% men, mean age 66.0±9.5 years, 28.9% asymptomatic) with ICA occlusion were included in this case-control study. Ultrasonographic Gray-Weale plaque type (I-IV, echolucent to echogenic) characterization was obtained in both the occluded and the contralateral ICA. Univariate and conditional logistic regression analyses with 1:1 pair matching per artery were undertaken. Each contralateral carotid artery with stenosis was treated as control to the ipsilateral-occluded ICA of the same patient. RESULTS: A total of 261 ICAs (61.9%) were recorded with type I-II plaque, of which 165 (63.2%) were among the occluded and 96 (36.8%) were among the contralateral ICAs with stenosis (P<0.001). Mean contralateral ICA stenosis was 58.2%±20.4%. Regression analysis showed that carotid plaque type I-II was significantly associated with carotid artery occlusion compared with plaque type III-IV (crude odds ratio [OR]=4.29, 95% confidence intervals [CI]=2.81-6.57%, P<0.001, adjusted OR=5.60, 95% CI=3.23-9.70, P<0.001). Previous neurological events did not seem to be significantly associated with plaque echolucency (OR=0.62, 95% CI=0.29-1.35, P=0.23). CONCLUSIONS: A significant association between echolucent plaque and ICA occlusion was observed. This observational hypothesis may prompt for further investigation of the causal mechanism between carotid plaque type and ICA occlusion by larger cohort studies.


Subject(s)
Carotid Artery, Internal/diagnostic imaging , Carotid Stenosis/diagnostic imaging , Plaque, Atherosclerotic/diagnostic imaging , Ultrasonography, Doppler, Duplex/methods , Aged , Carotid Artery Diseases/diagnostic imaging , Carotid Stenosis/etiology , Diagnosis, Differential , Disease Progression , Female , Follow-Up Studies , Humans , Male , Plaque, Atherosclerotic/complications , Retrospective Studies , Risk Factors
15.
J Vasc Surg ; 57(3): 668-77, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23317524

ABSTRACT

OBJECTIVE: To evaluate the impact of endograft type on the inflammatory response after elective endovascular repair of abdominal aortic aneurysms. METHODS: From January 2011 to November 2011, we included 100 consecutive patients who underwent elective abdominal aortic aneurysm endovascular repair. Thirteen patients were excluded from the analysis: four with cancer, three with autoimmune disease, two because of recent infection, two who were receiving long-term anti-inflammatory medication, and two because of recent surgery. Temperature, white blood cell count, platelet count, and serum concentrations of cytokines (interleukin [IL]-6, IL-8, and IL-10) were measured preoperatively, 24 hours postoperatively, and 48 hours postoperatively. The study sample was divided into four groups with respect to the type of endograft used: group A, n = 28 (Anaconda; Sulzer Vascutek, Bad Soden, Germany); group B, n = 26 (Zenith; Cook Inc, Bloomington, Ind); group C, n = 23 (Excluder; W. L. Gore and Assoc, Flagstaff, Ariz); and group D, n = 10 (Endurant; Medtronic, Minneapolis, Minn). Endograft configurations included bifurcated grafts only. RESULTS: Epidemiologic characteristics, atherosclerotic risk factors, type of anesthesia, mean blood loss during surgery, and baseline serum levels of cytokines did not differ among the four groups. Mean elevated temperature was more pronounced postoperatively in group A. Serum levels of IL-6 and IL-10 were significantly higher 24 hours and 48 hours postoperatively compared with preoperative levels in all groups. Patients in group C showed the smallest increase in levels of serum IL-6 and IL-10 at 24 hours and 48 hours postoperatively. Mean difference in cytokine levels after aneurysm exclusion was greater for group A vs group C (P < .01) compared with group A vs B (P < .05). No differences in the mortality and morbidity rates were observed among the four groups. CONCLUSIONS: Endograft type appears to influence the inflammatory response after endovascular aortic repair. The postimplantation syndrome was apparent during the first 24 hours and decreased afterward. Anaconda and Zenith endografts induced a more intense inflammatory response. A "milder" inflammatory activation was observed in patients with an Excluder endograft. The postimplantation syndrome was not associated with perioperative adverse clinical events showing a benign course. The possible long-term sequelae of postimplantation syndrome require further investigation.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Inflammation/etiology , Stents , Aged , Analysis of Variance , Aortic Aneurysm, Abdominal/mortality , Biomarkers/blood , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Body Temperature Regulation , Chi-Square Distribution , Elective Surgical Procedures , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Female , Humans , Inflammation/blood , Inflammation/immunology , Inflammation/mortality , Inflammation/physiopathology , Inflammation Mediators/blood , Interleukin-10/blood , Interleukin-6/blood , Interleukin-8/blood , Leukocyte Count , Male , Platelet Count , Prospective Studies , Prosthesis Design , Risk Factors , Time Factors , Treatment Outcome , Up-Regulation
16.
Vascular ; 19(5): 250-6, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21844248

ABSTRACT

Evolving technology has the potential to alter the overall management of carotid body tumors (CBTs). We review our 35-year experience emphasizing on novel modalities available in the evaluation and treatment of CBTs. Medical records of 27 CBT patients between 1975 and 2009 were retrospectively reviewed. The study cohort has been arbitrarily divided into two groups: the early years' group A (18 patients, 1975-1998) and the later years' group B (9 patients, 1999-2009). The most common presenting symptom was a painless lateral neck mass (89%). Octreotide scintigraphy and genetic testing were routinely used for group B. In two cases, octreotide scintigraphy was coupled with intraoperative radiolocalization of the lesion. Preoperative embolization was performed in four CBTs. Among group B patients, five were pretreated via a covered stent placement in the external carotid artery (ECA). Twenty-three patients (24 CBTs) were eventually operated upon. One cardiovascular death, one permanent vocal cord paralysis and six transient cranial nerve injuries account for a 4.4% 30-day mortality and a 30.4% morbidity with no significant differences among groups. In conclusion, appropriate use of new techniques in CBT management has improved diagnostic accuracy and early detection without clearly affecting overall outcome in our study cohort.


Subject(s)
Carotid Body Tumor , Embolization, Therapeutic/trends , Stents/trends , Vascular Surgical Procedures/trends , Adult , Aged , Antineoplastic Agents, Hormonal , Carotid Body Tumor/diagnostic imaging , Carotid Body Tumor/surgery , Carotid Body Tumor/therapy , Chemoradiotherapy , Early Diagnosis , Female , Follow-Up Studies , Humans , Male , Middle Aged , Octreotide , Postoperative Complications/diagnosis , Preoperative Care/trends , Radionuclide Imaging , Retrospective Studies , Young Adult
17.
J Endovasc Ther ; 18(4): 462-70, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21861731

ABSTRACT

In light of the results of randomized trials, it seems that despite the favorable short and midterm outcomes of standard endografts, concern over endograft migration has escalated, as this event will be responsible for almost all late complications in endovascular aneurysm repair (EVAR). Migration forces, both caudal and sideways, depend heavily on blood pressure, inlet diameter, and angulation of the stent-graft, while the bifurcation generates more force than any other segment of the stent-graft. It thus seems that the position of the endograft's flow divider influences force distribution and migration risk. Additionally, due to concomitant ongoing aortic degeneration, postoperative dilatation of the infrarenal aortic neck poses a threat to EVAR patients as soon as the diameter of the infrarenal neck reaches the dimensions of the proximal graft. This review evaluates the significance of endograft accommodation on the aortic bifurcation and cumulative experience of the only endografts utilizing this feature: the Zenith Composite and the Powerlink.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation , Foreign-Body Migration/prevention & control , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/physiopathology , Aortography/methods , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Foreign-Body Migration/etiology , Hemodynamics , Humans , Prosthesis Design , Risk Assessment , Risk Factors , Stents , Stress, Mechanical , Time Factors , Tomography, X-Ray Computed , Treatment Outcome
18.
Vasc Endovascular Surg ; 45(7): 646-50, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21862520

ABSTRACT

PURPOSE: Aim of this study is to present our initial experience with the use of the retrograde popliteal artery access in patients with certain anatomic lesions. METHODS: Between September 2008 and September 2010, 24 patients underwent a transpopliteal retrograde subintimal recanalization. Instead of its usage when antegrade recanalization failed, the "facedown" technique was preferred as a first choice in patients with common femoral artery stenosis or occlusion, proximal lesions of the superficial femoral artery (SFA) with no stump, severe obesity, tandem iliac, and SFA lesions. RESULTS: Technical success was achieved in 91.7% of patients.The complication rate was 12.5%. The primary patency at 6, 12, and 18 months was 86.4%, 65.8%, and 65.8%, respectively. CONCLUSIONS: The retrograde popliteal artery approach can be considered as the primary SFA recanalization strategy in carefully selected patients, with competitive immediate and midterm results.


Subject(s)
Angioplasty, Balloon/methods , Femoral Artery , Iliac Artery , Peripheral Arterial Disease/therapy , Popliteal Artery , Aged , Aged, 80 and over , Angiography, Digital Subtraction , Angioplasty, Balloon/adverse effects , Angioplasty, Balloon/instrumentation , Constriction, Pathologic , Female , Femoral Artery/diagnostic imaging , Femoral Artery/physiopathology , Greece , Humans , Iliac Artery/diagnostic imaging , Iliac Artery/physiopathology , Male , Middle Aged , Patient Selection , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/physiopathology , Popliteal Artery/diagnostic imaging , Stents , Time Factors , Tomography, X-Ray Computed , Treatment Outcome , Vascular Patency
19.
Int J Stroke ; 6(4): 337-45, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21745345

ABSTRACT

BACKGROUND AND PURPOSE: Accumulating evidence suggests that carotid plaque vulnerability can be used as a determinant of ischemic stroke risk stratification and carotid intervention. Novel markers of high-risk carotid plaque in patients are needed. SUMMARY OF REVIEW: Advances in cellular and molecular pathophysiology, the demand for accurately predicting carotid risk, and choosing the optimal prevention strategy are stimulating great interest in the development of novel surrogate markers. Biomarkers in cardiovascular disease are expected to predict the natural history, clinical outcomes, and the efficacy of disease-modifying interventions. We aimed to review the literature regarding clinical data on novel serum biomarkers related to ischemic cerebrovascular events associated with carotid artery disease. We provide background information on the biomarkers related to all aspects of carotid disease: natural history, carotid intervention strategies for symptomatic and asymptomatic patients, perioperative risk prediction, and their therapeutic implications. CONCLUSION: At present, heterogeneous data support evidence that biological markers can help existing practices to more accurately assess patients at risk for stroke. Randomized-controlled trials for carotid artery disease and carotid intervention, incorporating biomarkers, are needed.


Subject(s)
Biomarkers/blood , Carotid Artery Diseases/blood , Carotid Artery Diseases/diagnosis , Stroke/prevention & control , Carotid Artery Diseases/complications , Humans , Stroke/etiology
20.
Vascular ; 19(3): 159-62, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21652668

ABSTRACT

An 82-year-old man was transferred to our emergency department due to acute abdominal pain. He had undergone an endovascular abdominal aortic aneurysm repair (EVAR) six years ago. An intravenous contrast-enhanced abdominal computed tomography revealed the rupture of the abdominal aortic aneurysm (AAA) with a large retroperitoneal hematoma. A Talent (Medtronic, Santa Rosa, CA, USA) modular bifurcated endoprosthesis had vertically collapsed approximately 7 cm after losing its infrarenal fixation. As a result, it led to the repressurization of the aneurysm sac and rupture. The patient was successfully treated by placing three Talent (Medtronic) aortic cuffs. To our knowledge, this is the first reported case of endograft collapse that has manifested with aortic aneurysm rupture. Although they are gradually declining, considerable rates of complications create the 'Achilles' heel' of endovascular repair of AAAs. A lifelong follow-up strategy for patients treated for AAA with EVAR is essential for the early detection and treatment of complications of the procedure.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Aortic Rupture/etiology , Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis/adverse effects , Endovascular Procedures , Prosthesis Failure/adverse effects , Aged, 80 and over , Aortic Aneurysm, Abdominal/complications , Aortic Aneurysm, Abdominal/diagnosis , Aortic Rupture/diagnosis , Aortic Rupture/surgery , Humans , Male
SELECTION OF CITATIONS
SEARCH DETAIL
...